background image

07-01810A 2012-10 Warranty 07-00424 

Dri-Eaz Products, Inc. 

 

O P E R A T I N G   T H E   D R A G O N

 

Before First Use 

Some assembly is required before using the Dragon. 
See “Assembly Instructions,” p. 8. 

Use of the Dragon with an external fuel tank (sold 
separately) can significantly extend the run time. 
Converting the Dragon for use with an external tank 
requires a one-time modification of the external fuel line 
connections. See “Modifying the Dragon for use with the 
External Fuel Pick-up,” p. 7 for instructions.  

Choosing a location 

WARNING! Use the Dragon outdoors only. Place the 
unit on a level, stable surface. Be sure to chock the 
trailer wheels securely to prevent the unit from 
rolling. Choose a location away from high-traffic 
areas, children and pets, and ensure there are no 
obstructions to the air intake.  

 

CAUTION: 

Keep air intake vents clean and clear of any 

obstruction. Avoid setting up unit in a location where the 
intake could be blocked or restricted. Blocking the air 
intake will cause the unit to

 

produce sooty exhaust, 

potentially damaging the unit and the structure being 
heated. 

NOTICE: Install and operate the Dragon in accordance 
with all local and regional regulations. In Canada, refer 
to CSA B139 and CSA B140-1962. 

Fill the fuel tank 

The Dragon is shipped with the fuel tank empty. Before 
operating, fill the tank with no. 2 diesel or fuel oil. In cold 
conditions, a diesel-kerosene mixture as described on 
p. 2 may be used. The tank has a 13.5 gal. (51 L) 
maximum capacity. Do not overfill.  

CAUTION:

 Do not put gasoline, motor oil, or any other 

product in the fuel tank.  

CAUTION:

 Do not fill the tank while the unit is operating. 

KEY 

 E. Control Panel 

 A. Air intake  

 F. Fuel fill and cap 

 B. Furnace exhaust flue  

 G. Fuel level indicator 

 C. Fuel filter and fuel line connectors 

 H. Fuel tank drain plug (not shown) 

 D. Heated air outlet with 12 in. duct mounting ring 

  J. Heater access panel 

 

 

Figure 1: Parts Identification

 

Содержание F507

Страница 1: ...the unit and secondary damage when ducting into a structure It may also void the Dri Eaz warranty Refer to Adjusting for Altitude p 5 for instructions WARNING Breathing Hazard Fuel exhaust contains d...

Страница 2: ...e Furnace is designed to operate on a 115V 60 Hz electrical connection The unit requires 10 amps Make sure that the electrical outlet is a three prong type grounded outlet When using with an extension...

Страница 3: ...bstruction Avoid setting up unit in a location where the intake could be blocked or restricted Blocking the air intake will cause the unit to produce sooty exhaust potentially damaging the unit and th...

Страница 4: ...Operating the Dragon Inspecting before operation WARNING Before starting the Dragon Check for any fuel leaks around the fuel tank or fuel lines Check for nearby hazards like combustible materials or f...

Страница 5: ...or black there is not enough air in the mixture c If the smoke is white there is too much air and not enough fuel in the mixture or there is water in the fuel If the smoke color is either black or wh...

Страница 6: ...once a year 1 Cleaning the fuel tank The fuel tank should be cleaned once a year To clean the tank follow these steps a Place an appropriate container beneath the fuel drain plug to catch any fuel b R...

Страница 7: ...z 5 3 amps Fuel consumption 1 2 gal hr 4 5 L hr Fuel type Diesel fuel oil 2 Kerosene Fuel tank capacity on board 13 5 gal 51 1 L Rated heat output 130 000 BTU hr Process air output 900 CFM 1530 CMH Te...

Страница 8: ...and supplies required Wrenches Wheel base axle and wheel installation Attach the wheel base assembly to both sides of the tank using the fasteners provided Install both wheels Place a washer on either...

Страница 9: ...arranty 07 00424 9 Dri Eaz Products Inc Install rear stand First attach top of stand to the back edge of the tank using the fasteners provided Secure the front of the stand over the fuel drain plug wi...

Страница 10: ...2012 10 Warranty 07 00424 10 Dri Eaz Products Inc Exhaust flue installation Slide flue down over exhaust flange as shown Ensure all fasteners are properly tightened and secure The Dragon is now ready...

Страница 11: ...the existing fuel tank fitting from the tank Slide fitting off of fuel pickup tube and discard fitting 4 Using a tube cutter cut off metal pickup tube approximately in below the brass compression slee...

Страница 12: ...gs Attach the two nipples to the hexagonal fuel tank fitting Attach a quick disconnect socket to the top nipple Attach a quick disconnect plug to the bottom nipple Attach an adapter to each of the fue...

Страница 13: ...end of the return line Attach a quick disconnect socket to the adapter on the end of the fuel pick up line Attach a 90 fitting thru the filter bracket into the filter Rotate the fitting so that it po...

Страница 14: ...t and plug ends together External fuel tank pickup setup The pickup fuel line assembly provided must be installed in an external fuel tank not supplied before use 1 Remove the pickup tank cover 2 Scre...

Страница 15: ...07 01810A 2012 09 Warranty 07 00424 15 Dri Eaz Products Inc Fig 4 Electrical Schematic...

Страница 16: ...de s rie ______________________________________________________ Distributor Distribuidor Distributeur ____________________________ Tel Tel T l ________________________ MAINTENANCE MANTENIMIENTO MAINTE...

Отзывы: