PARTS IDENTIFICATION
(Shown, below)
Front (Intake) Filter View
Back View
SETUP
Place dehumidifier upright. When transporting the E81400 in a
horizontal position is necessary, set upright (vertically) for at
least 30 minutes before operation. When machine is placed in
a horizontal position, oil from the compressor flows into the
refrigerant coils reducing the ability of the EB1400 to function.
Place the unit on a level surface
Make sure the System switch is set to Off then plug power
cord into a standard 115V grounded outlet
3.
Set the digital temperature controls needed to function
(see below).
4.
Check for proper operation before leaving the unit
unattended. Do not move or carry the EB1400 when it is
running or plugged in
OPERATING RANGE
Recommended operating range is between 60° and 105°F (16°
and 46°C) The EB1400 will not function properly when
operating in an environment with temperatures outside this
range
CYCLE TIMES AND COMPRESSOR PROTECTION
The 031400 thermostat includes an automatic compressor
protection feature to avoid potential damage to the cooling
system from short cycling This thermostat automatically
provides a five minute delay after turning off the cooling system
output to protect the compressor. This protection is also
present while operating the unit in heating applications,
I mportant Notes:
• if unit loses power or gets unplugged during operation,
operator MUST wait five minutes before plugging unit back
in or risk damaging the compressor or tripping the circuit
breaker in the facility
• Aways turn the System switch to OFF before unplugging.
• If the System setting is adjusted during operation the unit
will automatically delay five minutes before start-up
• When switching unit from cooling to heating or heating to
cooling operator must adjust set point temperature.
TESTING
AND PROGRAMMING THERMOSTAT
DIGITAL CONTROLS
Digital display
Up
_es
.11
a•
Down
Duct 8-
Process air
heat recovery
outlet
Fan
control
On
Cool
Off
Heat
Auto
OPERATING INSTRUCTIONS
GETTING STARTED
PLACEMENT.
For cooling or heating, place at least one EI31400 per room
TO TEST THERMOSTAT:
1
Move the system switch from OFF to the HEAT position
Press the " button on the keypad until the set point
temperature setting is a minimum of three degrees higher
9