ERROR MESSAGES 

The table below shows error message that the system may detect. If the display shows an “ER” message, first unplug the 
unit and then plug it back in. This may re-set the electronics, and if so, no further action is required. If the error message 
reappears, try the solution shown under “Explanation.” If this still does not fix the problem, contact your local authorized 
service center or the Dri-Eaz Service Department at 800-932-3030. 

 

E R R O R

 

M E S S A G E  

E X P L A N A T I O N  

ER 1, 2, 3, 5, 6 

Problem with electronic control panel. Contact Dri-Eaz 
Service. 

ER 4 

Check the temperature or sensor cable. Contact Dri-Eaz 
Service for instructions. 

ER 8 

Check the control panel keys. Press and release each key 
several times.  

ER 9  

Check for obstructions or kinks in the drain hose. 

 

TROUBLESHOOTING 

 

F A U L T  

C A U S E  

S O L U T I O N  

Unit does not 
operate 

No power to machine. 
Unit not switched on. 

Plug in unit; check power at outlet and at base of unit. 
Switch unit on. 

Blower wheel 
not turning 

Obstructed blower. 

Remove duct ring and grill. 
Remove obstruction. 
Replace duct ring and grill. 

Unit operating, 
but room not dry 

Not enough time to dry. 
Poor air movement in room. 
Excessive moist air infiltration. 

Allow more time for drying. 
Increase air movement with air movers. 
Reduce infiltration. 

Unit 
continuously in 
defrost mode 

Room temperature too low 

Increase room temperature. 

Pump does not 
function 

Stuck float valve 

Clean float valve shaft. 

Unit collects too 
little water 

Room air is dry. 
Room temperature is too low. 

Check humidity with hygrometer. 
Increase room temperature. 
Check filter and coils; clean as necessary. 

If the problem you are experiencing is not listed here, call your local distributor or contact the Dri-Eaz Service 
Department toll-free at 800-932-3030. 

 

Содержание DrizAir F232-A GG

Страница 1: ...well as to contact you in case we have important safety information concerning your Dri Eaz product If you determine service is required have your equipment model serial number and original proof of...

Страница 2: ...d end in a sink drain bucket or outside anywhere that water can drain out safely If you use a bucket or other receptacle for water collection check it regularly to prevent spills NOTE Uncoil and strai...

Страница 3: ...Turn the power off using the OFF key and let the unit sit plugged in for about 10 minutes This allows water to drip from the coils and collect in the drip pan 2 Press PURGE to remove residual water De...

Страница 4: ...eing careful not to let the nozzle touch the fins as that may cause damage by bending them Check catch basin tray Clean when dirt and debris are present 1 Wipe clean with a rag Check drain hose 1 Look...

Страница 5: ...or kinks in the drain hose TROUBLESHOOTING F A U L T C A U S E S O L U T I O N Unit does not operate No power to machine Unit not switched on Plug in unit check power at outlet and at base of unit Sw...

Страница 6: ...day Water removal max 90 F 90 RH 200 pts 88 5 liters day Water removal 80 F 20 RH 16 pts 7 6 liters day Max process air 360 CFM 612 CMH Operating Range 33 100 F 1 38 C Air filter 3M HAF filter part no...

Страница 7: ...az Products Inc PURCHASE Purchase date ________________________ Serial number ________________________ Distributor ________________________ Tel _________________________ MAINTENANCE D A T E S E R V I...

Отзывы: