07-00283 C     12-02 Copyright 1999, Dri-Eaz Products, Inc.

 

TABLE OF CONTENTS 

INTRODUCTION .................................................................. 2 
WARRANTY ......................... 

Error! Bookmark not defined.

 

SAFETY INFORMATION ...................................................... 2 
PRINCIPLES OF OPERATION ............................................ 3 
 

Process Air ...................................................................... 3 

 

Reactivation Air ............................................................... 3 

OPERATING CONDITIONS ................................................. 4 
 

Saturated Environments .................................................. 4 

 

Lower Levels of Humidity ................................................ 4 

 

Monitoring Humidity Changes ......................................... 4 

 

Moisture Content of Materials ......................................... 4 

MAIN COMPONENTS .......................................................... 4 
 

Air Filter ........................................................................... 4 

 

Reactivation Air Stream ................................................... 4 

 

Rotor Drive ...................................................................... 5 

 

Main Controls .................................................................. 5 

 

Indicator Lights ................................................................ 5 

INSTALLATION & START-UP .............................................. 5 
 

Inspection ........................................................................ 5 

 

Positioning the Dehumidifier ............................................ 5 

 

Locating the Dehumidifier ................................................ 5 

 

Air Circulation .................................................................. 5 

 

Duct Connections ............................................................ 6 

 

Connecting the Ductwork ................................................ 6 

 

Connecting the Power ..................................................... 6 

MAINTENANCE.................................................................... 7 
 

Clean the Air Filters ......................................................... 7 

 

Check Reactivation Outlet Temperature ......................... 7 

 

Check the Rotor Air Seals ............................................... 7 

 

Check the Rotor .............................................................. 7 

 

Maintenance Quick Reference Summary ........................ 7 

TROUBLESHOOTING .......................................................... 8 
 

No Indicator Lights .......................................................... 8 

 

"Blower On" Light Is Off ................................................... 8 

 

"Heater On" Light Is Off ................................................... 8 

 

Reactivation Outlet Temperature Too Low ...................... 8 

 

Poor Dehumidifying Performance.................................... 8 

 

Rotor Is Stopped ............................................................. 8 

 

Checking the Heater Elements ........................................ 9 

SPECIFICATIONS .............................................................. 10 
TROUBLESHOOTING SUMMARY .................................... 11 
 

 

Congratulations

  on  your  selection  of  a  new  DriTec™ 

325 Desiccant Dehumidifier or a DriTec 150 Desiccant De-
humidifier from Dri-Eaz Products, Inc. It is our goal to offer 
you  the  best  high  performance  dehumidifier  available.  We 
invite your comments and suggestions for modifications and 
improvements.  Reading  this  Owner's  Manual  will  help  you 
achieve maximum benefits from your dehumidifier. 

Read Manual and Safety Information.

 Make sure that 

all  technicians  and  operators  who  use  the  DriTec  read  and 
understand  the  owner's  manual  prior  to  operation.  Pay  par-
ticular attention to the safety  information in order to reduce 
the risk of electrical shock, fire, or personal injury.  

Inspect  on  Arrival.

  When  your  DriTec  arrives,  check 

immediately  for signs of  shipping damage. If  you do notice 
any damage, report it to your supplier and the shipping com-
pany immediately. It is important to save the shipping carton 
for  claim  purposes.  If  your  DriTec  ever  needs  repairs  at  a 

remote location, the unit should be packed and shipped in its 
original carton.

 

INTRODUCTION 

The  DriTec  Desiccant  Dehumidifier  is  designed  to  re-

duce  humidity  by  removing  moisture  from  the  air.  Proper 
dehumidification  helps  to  speed  the  drying  of  wet  carpet, 
cushion,  floors,  walls,  contents  and  structural  materials.  It 
also  prevents  mold  and  mildew  growth  caused  by  moist  or 
humid conditions. 

The DriTec Desiccant can create extremely low humidity 

conditions, and can operate efficiently in very low tempera-
tures.  These  two  benefits  of  the  desiccant  dehumidifier  are 
not possible with refrigerant dehumidifiers. 

Your DriTec Desiccant Dehumidifier is durable and sim-

ple  to  operate,  needing  very  little  maintenance.  The  DriTec 
can  give  you  years  of  trouble  free  service  if  you  follow  the 
recommendations in this manual. 

We strongly advise that  you read and study the  manual. 

You  will  learn  how  your  desiccant  dehumidifier  works  and 
how to get the best service from your DriTec Desiccant. 

If  you  do  not  understand  something  in  this  manual  or  if 

you  have  a  question  about  your  dehumidifier,  call  the  Ser-
vice Department at Dri-Eaz Products, (360) 757-7776.  

SAFETY INFORMATION 

Dri-Eaz is concerned about the safety of anyone who us-

es or performs maintenance on the DriTec Desiccant unit. It 
is dangerous for an untrained individual to attempt to use or 
perform  maintenance  on  the  unit.  Throughout  this  manual 
we point out some of the precautions which should be taken 
in use or maintenance of the. 

We use three different kinds 

of messages to warn you of possible problems or precau-
tionary measures: 

 

Danger 

– 

Immediate  hazard  which  will  result  in  severe 

personal injury or death. 

Warning

  –  Hazard  or  unsafe  practice  which  may  result  in 

severe personal injury or death. 

Caution

  –  Hazard or  unsafe  practice  which  could  result  in 

personal injury or property damage. 

 

Please  keep  these  points  in  mind  as  you  use  or  service 

the unit. 

 

Never

  use  the  DriTec  325  or  the  DriTec  150  without  a 

proper  extension  cord.  Do  not  use  the  325  with  any  exten-
sion  cord  other  than  the  one  available  from  Dri-Eaz  Prod-
ucts. Use of any other extension cord may cause an electrical 
short or fire hazard. 

 

Never

  alter  the  grounding  plug  or  remove  it  from  the 

electrical cord. Do not use an adapter that defeats the dehu-
midifier’s electrical  grounding. This could cause  an electri-
cal shock or fire hazard. Do not use the unit for any reason if 
it cannot be properly grounded. 

 

Never

  operate  the  unit  in  standing  water,  because  of  the 

risk of serious electrical shock hazard. The unit may be oper-
ated on damp surfaces but not in standing or pooled water. 

Содержание DRITEC 150

Страница 1: ...s manual includes important safety warnings and operating information Please read before using the dehumidifier and save for future reference PURCHASE DATE _________________________ SERIAL NO ________...

Страница 2: ...Proper dehumidification helps to speed the drying of wet carpet cushion floors walls contents and structural materials It also prevents mold and mildew growth caused by moist or humid conditions The...

Страница 3: ...ard Always secure the unit to prevent sliding when transport ing in a vehicle which could cause injury to vehicle occu pants or damage to the vehicle or unit PRINCIPLES OF OPERATION DriTec Desiccant D...

Страница 4: ...move little additional water At this point many materials in the room such as carpets and wall surfaces may feel dry but moisture may remain in structural materials Ceilings walls and structural floor...

Страница 5: ...mum efficiency That is all doors windows and other openings to the outside should be closed tightly with the exception of an opening for the reactivation outlet wet air duct Locating the Dehumidifier...

Страница 6: ...o the unit If enough condensed water collects and blocks the air flow the unit can shut itself down Ducting Length The amount of air flow through the react and process ducting is dependent upon its di...

Страница 7: ...the air seals for any signs of abrasion or cuts Be sure the outer surface of the seals are smooth If the seals must be replaced please contact the Dri Eaz Service Department Check the Rotor 1 With the...

Страница 8: ...ircuit or for any mechanical problem that might keep it from turning freely 5 Restarting the unit Do not attempt to restart the unit until it is determined what caused the fault condition and correcti...

Страница 9: ...eals should be smooth If the seals must be replaced please contact the factory for in structions Checking the Heater Elements 1 The PTC heating elements are located behind the front panel just below t...

Страница 10: ...me 250 CFM 110 CFM Reactivation Air Volume 75 CFM 30 CFM Air Filter Cleanable Foam Cleanable Foam Max Reactivation Heater 4 5 kW 230 VAC 3 0 kW 115 VAC Max FLA 24 Amps 12 Amps Max Operating Temp For D...

Страница 11: ...ACTIVATION OUTLET TEMPERATURE TOO LOW SHOULD BE ABOUT 30 F 17 C ABOVE THE TEMPERATURE OF THE ROOM Check for source of increased moisture in the space being processed such as ducting leaks open doors o...