panels, a microprocessor measures and determines the

optimum operating charging point to charge the battery. A

low voltage disconnect is included in the design to protect

the battery from excessive discharge. Two LED’s provide

a visual indication as to the status of the controller. A

temperature sensor is also provided to monitor battery

temperature; this sensor provides feedback to the solar

converter and will adjust battery charge conditions

accordingly as the temperature changes.

Gel Cell Battery

All batteries conform to BCI specifications. Batteries are

maintenance free. Sealed construction eliminates: periodic

watering, corrosive spills and fumes. Electrolyte will not

stratify, no equalization charging required. Allows for faster

recharging intervals. Battery operating temperatures range

from -76°F (-60°C) to 140°F (60°C). All Batteries in

multi-battery configurations are to be wired in Parallel

(connecting Positive to Positive and Negative to Negative).

All batteries cables are equipped with a current limiting

devise to protect against an over current condition.

Simplex Pump

All pump heads have a standard 316 Stainless Steel body

and incorporate the Texsteam proven plunger and packing

design technology. Pump outputs are a basic setup input

feature. The Daily Volume input requirement and the head

size are all that is needed, simply Set It and Forget It. Daily

Volumes can be entered in either SI (System International)

Liters/Day or US customary units in Quarts/Day. Output

volumes remain constant as pressure requirements change.

Min/Max daily volumes based on continuous duty range

from 1.75 to 103 quarts/day (1.66 to 97.47 Liters). Output

pressures are achievable for the 3/16 and 1/4 in. pump head

models up to 5,000 psi.

Electric Motor

DC electric motors have gone through rigorous testing prior

to distribution to market. The motors are designed for: high

efficiency, low power consumption, long life, continuous

duty cycle and maintenance free.

Figure 17 – Pump and Electric DC

Motor Assembly

Motor Cover

Mounting Base

DC Motor

TEXSTEAM

field proven

Pump

Head Available in

3/16”, 1/4”, 3/8”,

and 1/2”

Figure 18 – Chemical Injection Pump Head

Elimination of Pump Drag and Friction

Packing Tightness

Particular attention should be given to Packing Nut tightness.

Over tightening of Packing Nut can result in excessive loses

of electrical power, which effects battery life, and pre-mature

seal packing degrading. The method for tightening all

Texsteam pumps is the same. NEVER ADJUST PACKING

WITH THE PUMP RUNNING. Loosen the packing gland nut

until you can feel that it is free, then retighten until you feel a

snug fit, then one more little tightening, the size of one

(only) notch in the packing gland nut. If this does not work,

stop the pump and tighten only one more notch.

O-Ring Seal

Priming Valve

O-Ring Seal

Locking Nut

Plunger

Packing Nut

Plunger Packing Kit

Содержание iCIP 100 Series

Страница 1: ...IVISION 2 GROUPS C D OR NON HAZARDOUS LOCATIONS ONLY Serialized Assemblies It is strongly advised that all assemblies remain a complete or unbroken serialized set for proper functionality These assemblies have been adequately sized based on the following variables Daily Solutions Volume Head Size Well Pressures Regional Solar Hours Temperature Number of Days without Sun Light and Quantities of Bat...

Страница 2: ...ing sure it is firmly centered and seated down Make sure that there aren t any shadows that could contact any portion of the solar panel Figure 3 Tilt Locking Set Screws Azimuth Locking Set Screw Solar Panel Alignment During sun hours the solar panels are used to recharge the battery voltage used during the night or non sun hours The solar mounting assembly should be adjusted to achieve Maximum Ef...

Страница 3: ...de 29 8 Declination Angle 23 5 53 3 Figure 4 Figure 5 Pipe Tee Solar Panel Angles for Various Latitudes Day of the Year Photovoltaic Module Angle Deg Your Latitude Deg 100 90 80 70 60 50 40 30 20 10 0 10 20 30 12 21 1 20 2 19 3 21 4 20 5 20 6 19 7 19 8 18 9 17 10 17 11 16 12 16 0 25 20 15 10 5 30 55 50 45 40 35 70 65 60 After adjusting the Azimuth and Tilt angle tighten down the set screws that se...

Страница 4: ... Negative Close the junction box and secure the lid using the captive screws provided A simple plug socket assembly has been provided to isolate or to disconnect the power from the Solar Panels to the electrical charging system for safety and general maintenance Do not plug in until all other connections have been completed After all connections have been made remove the cardboard cover Panels Pro...

Страница 5: ...el is located on the upper back wall of the Battery Enclosure It has been secured and is offset from the back mounting surface of the enclosure using four 10 32UNC Studs Motor and Pump Install Connect the DC motor cable end circular connector to the mating connector panel mount on the battery enclosure Reference Figure 7 A standard 6 foot motor wire harness comes pre assembled using a IP 67 Mil Sp...

Страница 6: ...re 13 LED Display RS232 485 PC Interface Connection Termination Joystick Selector PC Data Logging Communication Module Connection Quick Set Pump Starting Parameters 1 Toggle down through the menu tree Reference Figure 14 using the joystick control Reference figure 13 Go to SETUP UNITS and pick the units of measure US Quarts Day or SI Liters Day Press down on the joystick DONE should be displayed 2...

Страница 7: ...RS DUE TO HEAD SIZE MAIN HEAD SIZE 3 16 1 4 3 8 CLOCK MINUTE HOUR DAY MONTH YEAR IN 5 Display Only Liters Day Quarts Day Liters Quarts 0 59 0 23 1 31 1 12 2000 2079 Series 200 Series 400 Series 300 Display Only Display Only Display Only Display Only Display Only Display Only Display Only Display Only Display Only Display Only Display Only Display Only Display Only Display Only Display Only Display...

Страница 8: ...asily accessed downloaded into a CSV format spreadsheet or log file for further review Firmware Installation An install uninstall Firmware Upgrade Options Module is required and will be provided with reference to product Solar Solutions Series installation Identification or Serial Number This module will be available in the event of a firmware upgrade to the iCIP controller Upgrade Firmware on iCI...

Страница 9: ...is needed simply Set It and Forget It Daily Volumes can be entered in either SI System International Liters Day or US customary units in Quarts Day Output volumes remain constant as pressure requirements change Min Max daily volumes based on continuous duty range from 1 75 to 103 quarts day 1 66 to 97 47 Liters Output pressures are achievable for the 3 16 and 1 4 in pump head models up to 5 000 ps...

Страница 10: ...g nut to secure the head to the pump base has been tightened Reference Figure 19 Figure 19 An adjustment should be performed to minimize friction between the coupling and pump housing Reference Figure 20 Figure 20 3 to 4 threads should be visible Adjust coupling to minimize interface ...

Страница 11: ...11 Figure 21 Two Panel Two Battery Wiring Diagram Wiring Diagrams Wiring diagrams provided with units when shipped Consult Dresser if an additional or specific wiring diagram is needed ...

Страница 12: ...5 20 5 19 4 534 4 503 8 0 1000 0 1000 Triplex 5 65 20 5 19 4 798 6 755 7 0 500 0 500 Texsteam HiCIP Pump The Texsteam HiCIP solar powered pump combines the intelligence of the iCIP solar pump with the ability to pump almost 800 quarts per day 44 more volume per head than the standard iCIP pump The HiCIP pump does the work of 2 to 3 lower volume pumps thereby reducing the cost of ownership With onl...

Страница 13: ...Pump High Output Motor vs Texsteam iCIP Pump Standard Motor 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Pressure psi Volume Quarts Liters Day 266 252 150 142 104 98 67 63 46 44 High Output Motor Standard Motor 184 174 1 2 Head 3 8 Head 1 4 Head ...

Страница 14: ...orized Service Center WARNING Avoid personnel injury involving equipment that is in motion Always remove or disconnect power prior to service to the motor motor controller batteries charge controller solar panels WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS 1 DIVISION 2 ADVERTISSEMENT RISQUE D EXPLOSION LA SUBSTITUTION DE COMPOSANTS PUET RENDRE CE MATERIEL I...

Отзывы: