Dresser iCIP 100 Series Скачать руководство пользователя страница 6

3/16”

3

45

1.75

26.31

Quarts/Day

0 – 5000 PSI

3

45

1.66

24.87

Liters/Day

0 – 5000 PSI

1/4”

3

45

3.07

46.07

Quarts/Day

0 – 5000 PSI

3

45

2.91

43.61

Liters/Day

0 – 5000 PSI

3/8”

5

45

11.52

103.68

Quarts/Day

0 – 1500 PSI

1500 – 3000 PSI

5

45

10.90

98.12

Liters/Day

0 – 1500 PSI

1500 – 3000 PSI

1/2”

5

45

20.48

184.29

Quarts/Day

0 – 1000 PSI

1000 – 2000 PSI

5

45

19.38

174.43

Liters/Day

0 – 1000 PSI

1000 – 2000 PSI

6

Motor Controller and

Configuration Firmware

The motor Controller has been designed to provide four

different configuration packages. Features include: A variable

speed motor that will match pump output requirements; a

4-digit LED (Light Emitting Diode) front panel mount display;

Manual field input capabilities using a 5 position entry

joystick device and CSA approved Motor Controller.

Reference Figure 13.

The Basic “Solar Solutions Series 100” will incorporate

the programmable pumping input parameters.

Configurations files can be downloaded with the aid of a

laptop PC. These configurations files are easily saved

and stored in an Excel or XLS format. Reference the

User Terminal Handbook for full use of the

communication software.

Figure 13

LED

Display

RS232/485

PC Interface

Connection

Termination

Joystick Selector

PC Data Logging &

Communication Module

Connection

Quick Set Pump Starting Parameters

1.

Toggle down through the menu tree (Reference Figure

14) using the joystick control (Reference figure 13). Go

to “SETUP/UNITS” and pick the units of measure US

(Quarts/Day) or SI (Liters/Day). Press down on the

joystick, “DONE” should be displayed.

2.

Next go to “SETUP/HEAD SIZE” or Pump Head Size.

This will automatically set the pump displacement with

regards to the cam and plunger diameter. Select on of

the following head sizes: 3/16, 1/4, or 3/8 depending on

the size delivered.

Table 1 – Head Size vs. Volume Range

Press down on the joystick, “DONE” should be

displayed Select the head size based on the volume

requirements based on Table 1.

3.

Lastly go to “SETUP/DAILY VOLUME” and hold down

the Joystick either up or down to increase or decrease

the daily volume. Press down on the joystick, “DONE”

should be displayed. Daily volume is dependant on the

units of measure selected above in Step 1 and head size.

4.

Toggle up to “OPERATION”, move the joystick to the

right and select “RUN”, press down on joystick,

“DOWN” should be displayed, and the iCIP should now

be operating and pumping.

Low

High

Low

High

Measur

Standard

High Pressure

Head Size

RPM Range

Volume Range

Units of

Pressure Range

Содержание iCIP 100 Series

Страница 1: ...IVISION 2 GROUPS C D OR NON HAZARDOUS LOCATIONS ONLY Serialized Assemblies It is strongly advised that all assemblies remain a complete or unbroken serialized set for proper functionality These assemblies have been adequately sized based on the following variables Daily Solutions Volume Head Size Well Pressures Regional Solar Hours Temperature Number of Days without Sun Light and Quantities of Bat...

Страница 2: ...ing sure it is firmly centered and seated down Make sure that there aren t any shadows that could contact any portion of the solar panel Figure 3 Tilt Locking Set Screws Azimuth Locking Set Screw Solar Panel Alignment During sun hours the solar panels are used to recharge the battery voltage used during the night or non sun hours The solar mounting assembly should be adjusted to achieve Maximum Ef...

Страница 3: ...de 29 8 Declination Angle 23 5 53 3 Figure 4 Figure 5 Pipe Tee Solar Panel Angles for Various Latitudes Day of the Year Photovoltaic Module Angle Deg Your Latitude Deg 100 90 80 70 60 50 40 30 20 10 0 10 20 30 12 21 1 20 2 19 3 21 4 20 5 20 6 19 7 19 8 18 9 17 10 17 11 16 12 16 0 25 20 15 10 5 30 55 50 45 40 35 70 65 60 After adjusting the Azimuth and Tilt angle tighten down the set screws that se...

Страница 4: ... Negative Close the junction box and secure the lid using the captive screws provided A simple plug socket assembly has been provided to isolate or to disconnect the power from the Solar Panels to the electrical charging system for safety and general maintenance Do not plug in until all other connections have been completed After all connections have been made remove the cardboard cover Panels Pro...

Страница 5: ...el is located on the upper back wall of the Battery Enclosure It has been secured and is offset from the back mounting surface of the enclosure using four 10 32UNC Studs Motor and Pump Install Connect the DC motor cable end circular connector to the mating connector panel mount on the battery enclosure Reference Figure 7 A standard 6 foot motor wire harness comes pre assembled using a IP 67 Mil Sp...

Страница 6: ...re 13 LED Display RS232 485 PC Interface Connection Termination Joystick Selector PC Data Logging Communication Module Connection Quick Set Pump Starting Parameters 1 Toggle down through the menu tree Reference Figure 14 using the joystick control Reference figure 13 Go to SETUP UNITS and pick the units of measure US Quarts Day or SI Liters Day Press down on the joystick DONE should be displayed 2...

Страница 7: ...RS DUE TO HEAD SIZE MAIN HEAD SIZE 3 16 1 4 3 8 CLOCK MINUTE HOUR DAY MONTH YEAR IN 5 Display Only Liters Day Quarts Day Liters Quarts 0 59 0 23 1 31 1 12 2000 2079 Series 200 Series 400 Series 300 Display Only Display Only Display Only Display Only Display Only Display Only Display Only Display Only Display Only Display Only Display Only Display Only Display Only Display Only Display Only Display...

Страница 8: ...asily accessed downloaded into a CSV format spreadsheet or log file for further review Firmware Installation An install uninstall Firmware Upgrade Options Module is required and will be provided with reference to product Solar Solutions Series installation Identification or Serial Number This module will be available in the event of a firmware upgrade to the iCIP controller Upgrade Firmware on iCI...

Страница 9: ...is needed simply Set It and Forget It Daily Volumes can be entered in either SI System International Liters Day or US customary units in Quarts Day Output volumes remain constant as pressure requirements change Min Max daily volumes based on continuous duty range from 1 75 to 103 quarts day 1 66 to 97 47 Liters Output pressures are achievable for the 3 16 and 1 4 in pump head models up to 5 000 ps...

Страница 10: ...g nut to secure the head to the pump base has been tightened Reference Figure 19 Figure 19 An adjustment should be performed to minimize friction between the coupling and pump housing Reference Figure 20 Figure 20 3 to 4 threads should be visible Adjust coupling to minimize interface ...

Страница 11: ...11 Figure 21 Two Panel Two Battery Wiring Diagram Wiring Diagrams Wiring diagrams provided with units when shipped Consult Dresser if an additional or specific wiring diagram is needed ...

Страница 12: ...5 20 5 19 4 534 4 503 8 0 1000 0 1000 Triplex 5 65 20 5 19 4 798 6 755 7 0 500 0 500 Texsteam HiCIP Pump The Texsteam HiCIP solar powered pump combines the intelligence of the iCIP solar pump with the ability to pump almost 800 quarts per day 44 more volume per head than the standard iCIP pump The HiCIP pump does the work of 2 to 3 lower volume pumps thereby reducing the cost of ownership With onl...

Страница 13: ...Pump High Output Motor vs Texsteam iCIP Pump Standard Motor 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Pressure psi Volume Quarts Liters Day 266 252 150 142 104 98 67 63 46 44 High Output Motor Standard Motor 184 174 1 2 Head 3 8 Head 1 4 Head ...

Страница 14: ...orized Service Center WARNING Avoid personnel injury involving equipment that is in motion Always remove or disconnect power prior to service to the motor motor controller batteries charge controller solar panels WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS 1 DIVISION 2 ADVERTISSEMENT RISQUE D EXPLOSION LA SUBSTITUTION DE COMPOSANTS PUET RENDRE CE MATERIEL I...

Отзывы: