RS-232 input and IR Codes
Communication Specifications
Control of this unit is possible using a computer or automation device connected with a RS-232 cross cable (female
- female D-sub 9 pins cable). Communication specifications for this unit are as follows:
Pin assignation
Command Format
When sending a command to this unit, use the following data format:
Available Operating commands
Baud Rate
19200 bps
Data Format
Binary
Mode
Non-Synchronous
Character Length
8 bits
Parity
None
Start Bit
1 bit set to high
Stop Bit
1 bit set to low
X on/off
None
Flow Control
None
Pin
Signal
Function
Signal Direction
2
RxD
data
PC -> Projector
3
TxD
data
Projector-> PC
5
GND
ground
-
1,4,6-9
N/C
-
-
Header
Unit ID
Command
Data
EoD
1 byte
89h 01h
2 bytes
at least 1 byte
0Ah
Header
(21h): Operating command. PC -> Projector
(3Fh): Reference command. PC -> Projector
(40h): Response command. Projector -> PC
(06h): ACK. Projector -> PC
Unit ID
Fixed to (89 h 01h)
Command
2 bytes. See the list of the available commands below.
If Command code is “52h 43h”, the Data sent may also be sent to the
projector by a programmable
RCU
using NEC 5 protocole.
Data
1 byte. See the list of the available data for each command below.
EoD
Fixed to (0Ah)
Header (21h)
Command
Data
Description
Connection RS-232
00h 00h
none
Check the serial connection.
Power ON
50h 57h
31h
If the projector is in stand-by mode, this command
switch the unit ON.
Power OFF
50h 57h
30h
If the projector is powered ON, this command
switches this unit into Stand-by Mode.