background image

This might be a rare occassion and most of the times you will want the DIP 1 set to on. Nontheless, if 

you have to do it, let the unit warm up for 20 minutes, and then you can turn the DIP 1 off, with confi-

dence that the Oscillators are in tune.

AUTOTUNING TROUBLESHOOT

The Oscillators cannot stay in tune:

Make sure that the synthesizer is not affected by any heating elements (a/c, radiator, etc.) and that it is 

generally in a temperature stable environment. Have in mind that the Nyx V2 is an analog synthesizer 

with the pros and cons that comes with it. Also check that the DIP1 is ON or that before setting it to the 

OFF position, the unit has been warmed up, as described above.
I can hear the Autotuning on the background:

It has been observed that the Nyx V2, sometimes, when it is connected to other devices that add a gain 

element to its output and not directly to a monitor, may create a ground loop. This will cause the Auto-

tuning procedure to be audible at about -70dB. You can negate this, by setting the Nyx V2 AMP level at 

max and control the volume of the synthesizer from the connected device. Additionally, you can allow 

the unit to warm up for 20 minutes and then set the DIP1 to the OFF position.

DIP switch / Pin’s description

1 : Auto- tuning ON/OFF

2 : Paraphonic / Unison

3 : Midi Channel

4 : Midi Channel

5 : Midi Channel

6 : Service Mode

3+4+5 : Drone Mode

Service Mode / Fine Tuning Procedure

In order to tune the Nyx V2 synthesizer, a MIDI keyboard, a pair of speakers and a tuner is needed. Con-
nect everything and turn the unit on for at least 30 minutes on Autotune Mode (DIP1 ON).
1. Set both Tune potentiometers to center position (50%)

2. Set VCO routing at VCA

3. Set all modulations, modulators, filter and effects at 0%.

4. Set VCA HOLD and LEVEL to 100%.

5. Turn on the DIP 6 and restart the synth by toggling the power switch. A LED will start blinking under OSC2 Tune.

6. Toggle 5 times the Drone switch of the AMP and the LED will make a fast flashing sequence and then 

becomes stable. Toggle 5 times more this switch and the LED will start flashing fast. After 30 seconds 

or more the flashing speed will be decreased. The synth now is ready to start the auto-tune procedure. 

On this mode Glide sliders are repurposed as finetune controls.

7. Turn OSC1 level to 100% from the mixer.

8. On the MIDI keyboard press and hold A0 and with the Glide slider set the tune to match that note.

9. Set OSC2 level to 100% and set the glide slider to that note so no beating occurs.

10. Set OSC2 level to 0% and let the key.

11. Repeat steps (8,9,10) for A1, A2, A3, A4, A5 and A6 respectively.

12. When A6 is tuned turn DIP6 to off position and restart the synth.

ATTENTION!

Each time you release a key, for example if you press A2 and then release it, it will automatically store 

your current Glide (FineTune) settings for both oscillators for the octave C0-C7. Be careful so as not to 

accidentally hit any other key than the ones noted in the procedure above. If you do so you must repeat 

the whole process from the beginning. Be sure to follow it exactly as described.

12

Содержание Nyx V2

Страница 1: ...30 eurorack patch points in Athens GR 2 Oscillators 2 Function Generators Extensive Digital Reverb ANALOG SYNTHESIZER 12 24dB Dual Filter Owner s Manual...

Страница 2: ...Introduction 3 The Oscillators 4 The Filter 5 The Modulators 5 The Routing 6 The LFO 9 The Reverb 9 The Amp Drone Mode 9 Patch Bay 10 MIDI Interface and DIP Switch 11 The Service Mode 12 Limited Warr...

Страница 3: ...ded to its arsenal including 2 Voltage Controlled Oscillators White Noise Generator Extremely Flexible Dual Filter from simple 12dB oct Low Pass up to 24dB variable width Band Pass Multiple Routing Op...

Страница 4: ...the middle position as it is MIDI based and calculates the autotuning correction 3 Wave Select Switch to select either the saw wave or pulse wave for OSC 1 or the saw wave or triangle wave for OSC 2 4...

Страница 5: ...rious Filter combinations from a Classic 24dB oct Low Pass or even a variable width Band Pass Please refer to the ROUTING for more info The Modulators Nyx V2 offers 3 Digital Modulators Envelopes MOD1...

Страница 6: ...Let s have a look at the following scheme VCO ROUTE NOR Stands for NORMAL Both VCOs are sent to VCF1 SPLIT VCO1 is being sent to VCF1 and VCO2 is being sent to VCF2 VCA Both VCOs are being sent direc...

Страница 7: ...2 LP HP VCA VCF1 LP HP VCF2 LP HP VCA VCF1 LP HP VCF2 LP HP VCA VCF1 LP HP VCF2 LP HP BP Stands for BAND PASS The filters are in series but VCF1 is on HP mode and VCF2 is on LP mode HP Stands for HIGH...

Страница 8: ...B oct Low Pass VCF2 is free SPLIT VCO1 24dB oct Low Pass VCO2 12dB oct Low Pass VCO1 12dB oct Band Pass VCO2 12dB oct Low Pass VCO1 24dB oct High Pass VCO2 12dB oct High Pass VCO1 12dB oct Low Pass VC...

Страница 9: ...tely dry to wet sound Please note that overdriving the signal especially when the FEED is high will cause the effect to distort Also when setting the mix of the oscillators above 70 or applying too mu...

Страница 10: ...s output 10V max NOISE 14 OUT white noise 5V max LEVEL sets the level of the White Noise INPUTS 15 CV1 OSC1 CV input 1V oct 2 off to precision 10V 16 CV2 OSC2 CV input 1V oct 2 off to precision 10V 17...

Страница 11: ...ast note priority In paraphonic mode envelopes are always on retrigger mode Normally when releasing 2 pressed notes all sources will follow the note last pressed In Unison mode only one note will foll...

Страница 12: ...e the Nyx V2 synthesizer a MIDI keyboard a pair of speakers and a tuner is needed Con nect everything and turn the unit on for at least 30 minutes on Autotune Mode DIP1 ON 1 Set both Tune potentiomete...

Страница 13: ...upply voltages backward or faulty cable connection abuse of the product or any other causes determined by Dreadbox to be the fault of the user are not covered by its warranty normal service rates will...

Страница 14: ...PRESET Notes...