We recommend that the hot water distribution from the heater was as short as possible to minimise heat losses.
Heaters must be provided with a discharge valve
mounted on the cold service water inlet to the heater for potential
disassembly or repair.
When assembling the security equipment, follow ČSN 06 0830.
Electric connection
Perform the connection according to the scheme.
Factory connection must not be changed!
In the electric wiring casing remove the partition corresponding with the input wire diameter of
8 or
10.
Heater is connected to power supply 1 PEN AC 230V/50Hz via a fixed movable wire.
The circuit must contain a breaker disconnecting all poles of the network, and a circuit breaker (protector).
Installations in bathrooms, lavatories and showers must comply with the ČSN33 2000-7-701 standard.
To adjust the distance from the wall, connect the wire of the external protective equipotential bonding!!!
The degree of protection of electric parts of the heater is IP 45. Power input of electric element is 2000 W.
Respect the rules of protection against electrical injuries in accordance with ČSN 33 2000-4-41.