16
-
3.1.2
TEMPERATURE SETTING
Water temperature is set by turning the thermostat knob.
The desired symbol is adjusted against the fixed
point on the control panel (Figure 9).
Figure 9
Adjusting the thermostat knob to the left backstop does not mean permanent shutoff of the
heating element.
When the tank is in use without blocking the daily rate, we do not
recommend
the temperature to be set above 55°C. Select the "
OPTIMUM
“ symbol as the
maximum.
4
IMPORTANT NOTICES
4.1
INSTALLATION REGULATIONS
-
Check and exchange the Mg anode regularly.
-
No closing armature may be mounted between the tank and the safety valve.
-
If the overpressure in the eater main exceeds 0.6 MPa, a reduction valve must be mounted
before the safety valve.
-
All outlets of hot water must be equipped with a combination faucet.
-
Prior to the first filling the tank with water we recommend that the receptacle's flange
connection nuts are tightened.
-
It is not allowed to handle the thermostat, aside from temperature resetting with a control
button.
-
All electric installation handling, setting, and regulation feature exchange, may only be
implemented by a service company.
upper limit of temp.
range (approx. 80°C)
"anti
-
freezing"
temperature (about 8°C)
lower temperature range
limit (about 5°C)
fixed point on the
control panel
"ideal" temperature
(about 55
℃
)