SHR
521 20
© Dra
yton
06
334
SHR 521
20
.monen.
ind
d
7
|
1
3
2
backwards
forward
SET
(selection / adjustment mode)
The system monitoring display consists of 3 blocks:
mode
indication,
tool bar
and
system screen
(active system
scheme).
The
mode indication
consists of two lines. The upper
line is an alphanumeric 16-segment display, in which mainly
the mode names / menu items are shown. In the lower
7-segment display, the channel values and the adjustment
parameter are indicated.
Temperatures and temperature differences are indicated
in or .
2.2.1 Mode indication
only mode indication
2.2.2 Tool bar
The additional symbols of the
tool bar
indicate the current
system status.
only tool bar
2. Operation and function
2.1 Pushbuttons for adjustment
The controller is operated by 3 pushbuttons below the
display. The forward-key (1) is used for scrolling forward
through the menu or to increase the adjustment values.
The backwards-key (2) is accordingly used for the reverse
function.
To confirm the current mode, hold down button 1 for 2
seconds. If an
adjustment value
is shown on the display,
SEt
is indicated. In this case you can press the key „Set“ (3)
in order to change into input mode.
Select a mode by keys 1 and 2
Press key 3, so that „SEt“ flashes
Adjust the value by keys 1 and 2
Press key 3, so that „SEt“ permanently appears,
the selected value is now saved.
2.2 System monitoring display
!
Complete monitoring-display
Symbol
standard
flashing
relay 1 active
relay 2 active
maximum store limitation
active / maximum store
temperature exceeded
collector cooling function or
recooling function active
antifreeze- function activated
collector minimum limitation
or antifreeze function active
collector security shutdown or
store security shutdown active
+
sensor defect
+
manual operation active
an adjustment channel is
changed SET-mode