At the beginning, please do first:
¾
Wear a grounding device to avoid the damage from electrostatic discharge
¾
Be sure that power switch is OFF before you insert the power cord to power source
1
1
.
.
5
5
.
.
1
1
C
C
o
o
n
n
n
n
e
e
c
c
t
t
i
i
n
n
g
g
t
t
h
h
e
e
S
S
F
F
P
P
M
M
o
o
d
d
u
u
l
l
e
e
t
t
o
o
t
t
h
h
e
e
C
C
h
h
a
a
s
s
s
s
i
i
s
s
The optional SFP modules are hot swappable, so you can plug or unplug it before or after
powering on.
1.
Verify that the SFP module is the right model and conforms to the chassis
2.
Slide the module along the slot. Also be sure that the module is properly seated against
the slot socket/connector
3.
Install the media cable for network connection
4.
Repeat the above steps, as needed, for each module to be installed into slot(s)
5.
Have the power ON after the above procedures are done
T
T
P
P
P
P
o
o
r
r
t
t
a
a
n
n
d
d
C
C
a
a
b
b
l
l
e
e
I
I
n
n
s
s
t
t
a
a
l
l
l
l
a
a
t
t
i
i
o
o
n
n
In the switch, TP port supports MDI/MDI-X auto-crossover, so both types of cable,
straight-through (Cable pin-outs for RJ-45 jack 1, 2, 3, 6 to 1, 2, 3, 6 in 10/100M TP; 1, 2,
3, 4, 5, 6, 7, 8 to 1, 2, 3, 4, 5, 6, 7, 8 in Gigabit TP) and crossed-over (Cable pin-outs for
RJ-45 jack 1, 2, 3, 6 to 3, 6, 1, 2) can be used. It means you do not have to tell from them,
just plug it.
1.
Use Cat. 5 grade RJ-45 TP cable to connect to a TP port of the switch and the other
end is connected to a network-aware device such as a workstation or a server.
2.
Repeat the above steps, as needed, for each RJ-45 port to be connected to a Gigabit
10/100/1000 TP device.
3.
Now, you can start having the switch in operation.
P
P
o
o
w
w
e
e
r
r
O
O
n
n
The switch supports 100-240 VAC, 50-60 Hz power supply. The power supply will
automatically convert the local AC power source to DC power. It does not matter whether
any connection plugged into the switch or not when power on, even modules as well. After
the power is on, all LED indicators will light up immediately and then all off except the
power LED still keeps on. This represents a reset of the system.
F
F
i
i
r
r
m
m
w
w
a
a
r
r
e
e
L
L
o
o
a
a
d
d
i
i
n
n
g
g
After resetting, the bootloader will load the firmware into the memory. It will take about 30
seconds, after that, the switch will flash all the LED once and automatically performs
self-test and is in ready state.
Содержание VigorSwitch G2080
Страница 1: ...VigorSwitch G2080 User s Guide Version 1 0 Date 2008 03 06 Copyright 2008 All rights reserved ...
Страница 26: ...VigorSwitch G2080 User s Guide 20 Office network ...
Страница 60: ...VigorSwitch G2080 User s Guide 54 ...
Страница 82: ...VigorSwitch G2080 User s Guide 76 ...
Страница 103: ...VigorSwitch G2080 User s Guide 97 ...
Страница 118: ...VigorSwitch G2080 User s Guide 112 ...