background image

 

 

Declaration of Conformity 

Hereby, DrayTek Corporation declares that the radio equipment type VigorAP 918R is in compliance 

with Directive 2014/53/EU. 

The full text of the EU declaration of conformity is available at the following internet address: 

http://www.draytek.com.tw/ftp/VigorAP 918R/Document/CE/ 

Manufacturer: DrayTek Corp. 

Address:   

No. 26, Fu Shing Road, HuKou Township, HsinChu Industrial Park, Hsin-Chu County, 
Taiwan 303 

Product:  

VigorAP 918R Series 

Frequency Information for Europe area: 

2.4G WLAN 

2412MHz - 2472 MHz, max. TX power: 19.98dBm      *1 

5G WLAN 

5160MHz - 5340 MHz, max. TX power: 22 dBm         

*2 

5480MHz - 5720 MHz, max. TX power: 27 dBm   

 

Requirements in AT/BE/BG/CZ/DZ/DK/EE/FR/DE/IS/IE/IT/EL/ES/ 

CY/LV/LI/LT/LU/HU/MT/NL/NO/PL/PT/RO/SI/SK/TR/FI/SE/CH/ 
UK/HR. 5150MHz~5350MHz is for indoor use only. 

(*1: for 2.4G WLAN model; *2: for 5G WLAN model)   

This product is designed for 2.4GHz /5GHz WLAN network throughout the EC region.

 

 

Regulatory Information 

Federal Communication Commission Interference Statement 

This equipment has been tested and found to comply with the limits for a Class B digital device, 

pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection 
against harmful interference in a residential installation. This equipment generates, uses and can 

radiate radio frequency energy and, if not installed and used in accordance with the instructions, may 
cause harmful interference to radio communications. However, there is no guarantee that 

interference will not occur in a particular installation. If this equipment does cause harmful 
interference to radio or television reception, which can be determined by turning the equipment off 

and on, the user is encouraged to try to correct the interference by one of the following measures: 

 

Reorient or relocate the receiving antenna. 

 

Increase the separation between the equipment and receiver. 

 

Connect the equipment into an outlet on a circuit different from that to which the receiver 
is connected. 

 

Consult the dealer or an experienced radio/TV technician for help. 

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two 

conditions: 

(1) This device may not cause harmful interference, and 

(2) This device may accept any interference received, including interference that may cause 
undesired operation. 

ii 

Содержание VigorAP 918R Series

Страница 1: ...i ...

Страница 2: ...ii VigorAP 918R Series 802 11ac Outdoor AP Quick Start Guide Version 1 0 Firmware Version V1 3 0 For future update please visit DrayTek web site Date February 5 2020 ...

Страница 3: ...tion outdoor to prevent electronic shock hazards Keep the package out of reach of children When you want to dispose of the router please follow local regulations on conservation of the environment Warranty We warrant to the original end user purchaser that the router will be free from any defects in workmanship or materials for a period of two 2 years from the date of purchase from the dealer Plea...

Страница 4: ...s for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guar...

Страница 5: ...other antenna or transmitter End users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance Caution Any changes or modifications not expressly approved by the grantee of this device could void the user s authority to operate the equipment Any changes or modifications not expressly approved by the party res...

Страница 6: ...ing Ethernet Cable 5 3 3 Pole Mount Installation for VigorAP 918RPD 6 3 4 Pole Mount Installation for VigorAP 918R 7 3 5 Wall Mount Installation for VigorAP 918R 8 3 6 Grounding Access Point 8 3 7 Powering Access Point 10 4 Connection and Configuration 11 Connected As a Mesh Node in Mesh Network 12 Connected As an Access Point 12 5 Customer Service 14 Be a Registered Owner 14 Firmware Tools Update...

Страница 7: ...n nt t Take a look at the package content If there is anything missed or damaged please contact DrayTek or dealer immediately Main Unit Antennas Ethernet Cable 3M Quick Start Guide Ground Cable Screws Pipe Clamp Mount Kit for VigorAP 918RPD 1 ...

Страница 8: ...s between 73dBm 67dBm 5G Signal For D Model No signal or the signal strength is 73dBm Interface Description Factory Reset Restore the default settings Usage Switch on the access point Press and hold reset button for at least 10 seconds The router will restart with the factory default configuration Before pressing the button the cover should first be removed by rotating it with a torque of 13 kgf c...

Страница 9: ... installing the VigorAP Note For the sake of personal safety only trained and qualified personnel should install this device 3 3 1 1 A An nt te en nn na as s I In ns st ta al ll la at ti io on n 1 Remove the protective cap 2 Insert the antennas and fasten them by rotating clockwise Warning Do not open the top cover of the device Installation during thunderstorms could be dangerous 3 ...

Страница 10: ... Port 1 PoE In 2 Before connecting verify that the cable has a rubber seal and that it is not damaged Note To prevent the enclosure from water leakage make sure the Ethernet cable gland and the rubber gasket are present and installed properly 3 Inserting RJ 45 connector into the port 4 Use an adjustable wrench and tighten the thread lock sealing nut with torque 10 kgf cm Note Do not pull the cable...

Страница 11: ... bl le e 1 Loosen the thread lock sealing nut 2 Loosen the clamping claw and seal 3 Loosen the body and washer 4 Remove the cable 5 To reattach the cable follow the above steps in reverse Note The diameter for the Ethernet cable shall be limited between 4 3mm to 5 9mm 5 ...

Страница 12: ...ig go or rA AP P 9 91 18 8R RP PD D 1 Find a suitable location for installing the access point 2 Select a mounting point on a pole 3 Attach the mount kit assembly to the mounting plate by locking four screws with the torque of 10 kgf cm 4 Insert the pipe clamp into the mount kit assembly 6 ...

Страница 13: ... 60mm 3 3 4 4 P Po ol le e M Mo ou un nt t I In ns st ta al ll la at ti io on n f fo or r V Vi ig go or rA AP P 9 91 18 8R R 1 Find a suitable location for installing the access point 2 Select a mounting point on a pole 3 Insert the pipe clamp on the access point Press the pipe clamp to open it for clamping the pole 7 ...

Страница 14: ...e screws on the anchors 3 Lock the screws on the anchors 4 Hang the access point on the anchors 4 Hang the access point on the anchors 5 5 W Wa al ll l M Mo ou un nt t I In ns st ta al ll la at ti io on n f fo or r V Vi ig go or rA AP P 9 91 18 8R R 3 3 6 6 G Gr ro ou un nd di in ng g A Ac cc ce es ss s P Po oi in nt t In outdoor installations and before powering the access point with AC power Vig...

Страница 15: ...5 Connect the ground rod and the VigorAP using the ground cable Note Please consult an electrician if you are uncertain about the type of grounding that is required 9 ...

Страница 16: ... codes Not place the power injector VigorSwitch in outdoor environment without any protection Moisture might get into the power injector and cause a short circuit or possible fire Not work on the system during periods of lighting activity to avoid the risk of electric shock and do not connect or disconnect the Ethernet cables under bad weather Below shows two examples of connecting power for Vigor...

Страница 17: ...u for a username and password Please type admin admin for Username Password and click Login Note You may either set up your computer to receive an IP address dynamically from the router or manually enter an IP address that is within the same subnet as the IP address of VigorAP 918R If there is no DHCP server on the network the VigorAP 918R will have an IP address of 192 168 1 2 If there is DHCP av...

Страница 18: ...thin the mesh network The user must detect VigorAP 918R series via a Mesh Root to add it as a mesh node C Co on nn ne ec ct te ed d A As s a an n A Ac cc ce es ss s P Po oi in nt t As an access point VigorAP 918R series must be connected to a router and configured in AP Access Point mode Connect VigorAP to a Vigor router Use a twisted pair cable with RJ 45 plugs at both ends and plug into Ethernet...

Страница 19: ...r PC and type https 192 168 1 2 A pop up window will open to ask for username and password b After clicking Login Quick Start Wizard for configuring wireless settings will appear as follows c Follow the on screen steps to finish the network connection 13 ...

Страница 20: ...devices will be regularly upgraded Please consult the DrayTek web site for more information on newest firmware tools and documents http www draytek com GPL Notice This DrayTek product uses software partially or completely licensed under the terms of the GNU GENERAL PUBLIC LICENSE The author of the software does not provide any warranty A Limited Warranty is offered on DrayTek products This Limited...

Отзывы: