3.4.2 Bridge 

This page is for Bridge configuration including, 802.1P, IGMP leaved mode, QoS 
configuration, and Max Unicast address. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bridge Port 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
Display the number of the profiles that system offered. 

1 – 48 represents port 1 to port 48. 

 

 
 

Editing Bridge Profile 

Click the radio button of the profile you want to edit. Next, click

 Edit

 to open it. Below 

shows the detailed web page. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

47 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

User’s Guide

Содержание VigorAccess-A48M-2-SFP-A-1-AC

Страница 1: ...i ...

Страница 2: ...User s Guide ii ...

Страница 3: ...VigorAccess A48M 2 SFP A 1 AC ADSL2 2 IP DSLAM User s Guide Version 1 0 Date 25 06 2009 This manual is available for Vigor Access with Annex A Annex M and Annex L Annex B iii User s Guide ...

Страница 4: ...n a damp or humid place e g a bathroom such as this environment Avoid operating cable connection during lightning period When you want to dispose of the VigorAccess please follow local regulations on conservation of the environment Users can replace fuses by removing the module and replace it when necessary Other components should be repaired by authorized and qualified personnel Do not try to ope...

Страница 5: ...ication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accor...

Страница 6: ...L network throughout the EC region and Switzerland with restrictions in France Please see the user manual for the applicable networks on your product Customer Support Please prepare the following information before you contact your customer support Product model and serial number Warranty information Date that you received VigorAccess Product configuration Software release version number Brief des...

Страница 7: ...ix A48 Devices 18 2 4 5 CPP Centric Patch Panel 20 2 5 Power Connection 22 2 6 Optical Fiber Connection SFP Optional 24 2 7 Console Port Connection 26 3 Web Configuration 27 3 1 System Configuration 27 3 1 1 Status 28 3 1 2 SNMP Config 29 3 1 3 IP Config 30 3 1 4 Default Route 30 3 1 5 Commit 31 3 1 6 Reboot 31 3 1 7 Firmware Upgrade 31 3 1 8 Configuration Backup Restore 34 3 2 DSL Configuration 3...

Страница 8: ...r 52 A 3 Alarm Port RJ45 Connector 52 A 4 RS232 Connector 53 A 5 Standard 10 100 Base T Ethernet Interface Connector 54 A 6 Standard 10 100 1000 Base T Ethernet Interface Connector 55 A 7 Contacting Your Dealer 55 User s Guide viii ...

Страница 9: ... and tag based VLAN VigorAccess can isolate traffic between different users and provide improved security 1 1 Features of VigorAccess The VigorAccess Integrated Ethernet Switch is an IP based DSLAM Internet Digital Subscriber Line Access Multiplexer that connects to 48 ADSL subscribers to the Internet When deployed together with DSL modems and WAN routers the combination forms are integrated solut...

Страница 10: ... packet which source MAC address is met with one of the 8 entries this packet can be forwarded to destination port Access Control List per device is up to 1024 entries If port receives a packet which source MAC address is met with one of these entries this packet would not be forwarded to destination port The high priority of ACL rules is the allowing rule checking for per port MAC Address Media A...

Страница 11: ...lity of Service QoS refers to the capability of a network to provide better service to select network traffic over various technologies The primary goal of QoS is to provide priority including dedicated bandwidth controlled jitter and latency required by some real time and interactive traffic and improved loss characteristics Also it is important to make sure that providing priority for one or mor...

Страница 12: ...in following sections Rate Limitation VigorAccess supports a function for throttling flooded packets Users can configure some limited rates by per port Static Mac Address VigorAccess supports this feature to be configured with certain ports to learn MAC addresses on a semi permanent basis These learned entries would be treated similar to the static entries but will not be subject to aging or overw...

Страница 13: ...ided Users may write their own applications to terminate and act on this information On the other side it also supports for capturing packets coming to Control Plane that do not match any registered filter Multiple Filter Stages VigorAccess supports a concept of multiple filter stages are provided for ingress and egress filter rules Moreover VigorAccess supports an Egress filtering for unicast bro...

Страница 14: ...s stream TV Service Video on Demand Service Service provider can offer multimedia services by setting up video or content server on the local side By combining rich content video server VigorAccess also provides the video on demanded service Users can easily access multimedia content based on VigorAccess architecture Combined with VoIP Service VigorAccess can combine IAD DSL VoIP gateway with high...

Страница 15: ...ISP and allows users to share the multiple services In addition the users can access into Intranet through WAN ports to communicate with others with PSTN feature by using routers CPE Customer Premise Equipment or IAD Integrated Access Device In general VigorAccess can handle and control all of the services for saving user s money with quick speed through Fiber connection and it can simplify the co...

Страница 16: ... system integrator provides multiple services with VoIP Video on Demand and ADSL2 bundle solution etc In addition the firewall and VPN security of VoIP security router is also provided by the architecture to meet business requirements This application is suitable on Hotel and MTU Multi Tenant Unit applications The entire system is managed by EMS system The following graphic shows the possible appl...

Страница 17: ... operate by default configuration Connected to PSTN normally Connected to twist pair of subscriber line which connects ADSL devices or telephones for users Warning The laser energy of the fiber optic communication channels in the single mode will be harmful when operate especially to the eyes During normal operation with cable connection this energy is confined to the cable with no danger present ...

Страница 18: ... when LNK LED is on G3 G4 LNK Green When the optical connection is established it will blink during data transmitting receiving OFF It means no optical connection established CR MJ MN ACT PWR DSL 1 48 Green OFF Green OFF Green OFF Green OFF Green OFF Green Critical alarm is present No critical alarm is present to system Major alarm is present No major alarm is present to system Minor alarm is pres...

Страница 19: ... hardware connection To fully setup the VigorAccess connection you have to finish the following items Rack mounted installation Line interface connection ADSL port connection Phone interface connection Below shows an example of VigorAccess network connection for your reference 11 User s Guide ...

Страница 20: ... bracket installation VigorAccess chassis could be installed in the rack by using two screws for each side of rack 2 2 Desktop Placement The VigorAccess can be placed on the rack or on a flat surface There are four rubber feet attached on the bottom of the VigorAccess to stabilize the device for placing on a flat surface These rubber feet aims to improve the air circulation and at the same time it...

Страница 21: ...ront of the VigorAccess which is powered by DC connector Connect the frame ground to a building s earthing terminal by using frame ground wire Importance Please connect the frame ground first before you connect any other cables for this device 13 User s Guide ...

Страница 22: ...and then to outside connection The traditional connection via MDFs for the phone set used in family is shown as the following picture The telephone set must connect to one port in this case Port 1 of MDF 1 meanwhile that port must connect to corresponding place of MDF 2 Next the other end of Port 1 in MDF 2 will connect to PSTN An example for MDF connection through VigorAccess is shown as the foll...

Страница 23: ...rnet cable Connect the MDF 1 to Line port of the A48 device Connect the Phone port of the A48 device to the matching connector in this case it is number 9 be careful and not to misconnect to MDF 2 which will be connected to PSTN This step is just useful for PC 3 for the user wants to call out through the A48 device Connect the device and ISP with Fiber cable through G3 G4 port With such connection...

Страница 24: ...nt to access the Internet through the Slave and Master devices As for the connection please follow the steps below 1 2 3 4 5 Connect PC 3 to number 9 of MDF 1 PC 2 to number 5 of MDF 1 and PC 1 to number 1 of MDF 1 Connect the MDF 1 to Line port of the Slave device Connect the Phone port of the Slave device to the matching connector in this case it is number 9 be careful and not to misconnect to M...

Страница 25: ... connector of the Master device Yet only PC 3 can call out with a telephone set directly Such connection allows 48 ADSL CPE routers to connect to outside Internet via the A48 device If you want to connect more of the routers please refer to next scenario for one A24 and six A48 devices connection 17 User s Guide ...

Страница 26: ...ce 1 to the matching connector in this case it is number 9 be careful and not to misconnect to MDF 2 which will be connected to PSTN This step is just useful for PC 3 for the user wants to call out through the Slave Device 1 Connect G1 or G2 port of the Slave Device 1 and G6 port of the Master device with Ethernet cable As to the connection among the Master device and Slave Device 2 to Slave Devic...

Страница 27: ... master and slave devices use CLI command Admin dsl m Press exit to return Entering character mode Escape character is dsl master or Admin dsl s n Press exit to return Entering character mode Escape character is dsl slave n 19 User s Guide ...

Страница 28: ...any in a basement or telephone room The CPP is the point of termination for the outside telephone company lines coming into a building and the telephone lines in the building The existing telephone wiring usually depends on user s region Here are descriptions of two typical installation scenarios Use telephone wires with RJ 11 jacks on one end for connecting to the CPP board Scenario A Users can c...

Страница 29: ... in VigorAccess You can connect a RJ 11 jack port attached in a CPP to a telephone directly or applied in the same way shared in ADSL modem The following example shows the connection for Data Voice transmission through CPP 21 User s Guide ...

Страница 30: ...ted with the following parts first DC Power Cord Y type terminator DC Power Terminator Head Follow the steps below to complete the power cord combination 1 2 Insert the DC Power Cord into the socket of DC Power Terminator Head Use the screwdriver to fasten the power cord inside the head 3 The assembled power cord with head should be the same as the following User s Guide 22 ...

Страница 31: ...ure shows the DC power supply terminal block It is the lugs at the wiring end from the power source The wiring procedure is for ground to ground positive to positive and negative to negative in order The ground wire should always be connected first and disconnected last 23 User s Guide ...

Страница 32: ...tions are to avoid injury when connecting or disconnecting optical channel Always connecting optical cables before power on Always keep the protective cap on the optic connector Never stare into an optical cable or connector when the connector is not in use A48 only supports SFP module for optical fiber connection There are two types of connectors that the SFP module supports LC and RJ45 connector...

Страница 33: ...eam is shown below Follow the steps below to connect the fiber channel 1 2 3 4 Read and understand the previous warnings and alarm Remove the protective caps from the fiber optic connector and from the external data cable Attach the external cable to the recessed connector on the faceplate To avoid exposure to laser radiation plug the protective cap Store protective cap on the clear place to use w...

Страница 34: ... and connect it to a network module through the console port Users can connect the RJ 45 end of the console cable to the console port of the network module On the other side users can connect the other end to a serial port RS232 of a computer Beware that the default login is admin password is 1234 Bootloader Version V1 XX Press ENTER key within 5 sec to download image 0 Please wait a minute Login ...

Страница 35: ...ow Browse master control http IP address Browse master dsl http IP address 8800 Browse standalone Slave http IP address The default value for user name is admin and the password is 1234 Next click OK 3 1 System Configuration For the system setup there are several items provided for you to configure Status SNMP Config IP Config Default Route Commit Reboot Firmware Upgrade Setup and Configuration Ba...

Страница 36: ...p Time HwVersion CPSwVersion DPSwVersion User s Guide Type a name to show the nature of such device Type a name for such device Type the physical location of such device e g Hsinchu Taiwan Type the textual identification of the contact person for such device together with information on how to contact this person e g Mr Lin phone 886 3 5972727 ext 123 Type the vendor specific information e g Drayt...

Страница 37: ...ation and make this information available to NMSs by using SNMP Managed devices sometimes called network elements can be routers and access servers switches and bridges computers hosts or printers This function is to define a community string name An agent is a network management software module that resides in a managed device An agent has local knowledge of management information and translates ...

Страница 38: ... subnet mask for DSL module Click Apply to save the settings Note If IPDSLAM is used standalone the user needs to configure these settings for management The default value is 0 0 0 0 for both 3 1 4 Default Route A default route is the network route used by a router when no other known route exists for a given IP packet s destination address All the packets for destinations not known by the router ...

Страница 39: ...ith the lasted configuration Reboot the system with factory default values except IP and VLAN for management only 3 1 7 Firmware Upgrade This page allows users to upgrade firmware through a Web interface In the System group click the Firmware Upgrade option You can see the following page then Before you execute the firmware upgrade please download the newest firmware from Draytek s website www dra...

Страница 40: ...nect the RJ45 connector of console cable to the console port on Vigor device and the DB9 connector of the console cable to the RS232 port on the PC The default setting of the console port is baud rate 57600 no parity and 8 bit with 1 stop bit Power on Vigor device then press ENTER before the system reboots completely Open Hyper Terminal on the PC Now the device can accept a TFTP download and will ...

Страница 41: ... message is shown as follows firmware upgrade firmware firle name all tftp server ip Now in the Console you will find the following information When Updating flash block at bfXXXXXX appears it means the firmware is under downloading When Start Upgrding appears it means the firmware downloading has been completed 33 User s Guide ...

Страница 42: ...anual 3 1 8 Configuration Backup Restore Most of the settings can be saved locally as a configuration file and can be applied to another router VigorAccess supports the restore and upload functions of the configuration files Open System Configuration Backup Restore You can see the following page User s Guide 34 ...

Страница 43: ...Restore Backup Click this button to restore the previous saved configuration file and apply to the device Click this button the backup current configuration file 35 User s Guide ...

Страница 44: ...in the corresponding fields and click Apply button Port Number Downstream Upstream Rate User s Guide Choose the port that you want to set The port number includes 1 48 Configure DSL Downstream Upstream transmit rate related parameter Intl Max TX Rate bps Configure Maximum Transmit rate for Interleaved channel in bps Intl Min TX Rate bps Configure Minimum Transmit rate for Interleaved channel in bp...

Страница 45: ...power 7 or better to successfully complete initialization for Noise Margin Max SNR Margin Configure Maximum Signal Noise Margin for rate downshift or upshift Min SNR Margin Configure Minimum Signal Noise Margin for rate downshift or upshift Rate Mode Type Trellis PsdMask Type Defines what form of transmit rate adaptation is configured on this device It is used to configure the ADSL physical line m...

Страница 46: ...stream bearer channel Upstream Minimal INP Interleave Depth Downshift SNR Mgn Upshift SNR Mgn Min Downshift Time Min Upshift User s Guide Parameter used to specify the minimum impulse noise protection for the upstream bearer channel Minimum interleaving depth supported by the customer s hardware Configured Signal Noise Margin SNR for rate downshift If the noise margin falls below this level the mo...

Страница 47: ...L2 state and the first Power Trim power saving in the L2 state and between two consecutive Power Trims in the L2 State This parameter represents the maximum aggregate transmit power reduction in dB that can be performed through a single Power Trim in the L2 state This parameter specifies the minimum net data rate during the low power state L2 This parameter allows the user to set a Current Traffic...

Страница 48: ...DSL line name Display current operation status Display current used DSL standard Display current down rate Display current up rate Display the Noise Margin seen by this ATU with respect to its received signal in tenth dB in CO side Display the total output power transmitted by this ATU in CO side Display measured difference in total power transmitted by the peer ATU and the total power received by...

Страница 49: ...Margin seen by this ATU with respect to its received signal in tenth dB in CPE side Renew the current displayed information 3 2 3 Performance It shows error counts during current 15 minutes or current day or before Port Number Type Refresh 3 3 PVC Configuration Choose the port that you want to see The port number includes 1 48 The CPE ATUR or DSLAM ATUC side Renew the current displayed information...

Страница 50: ...r the Virtual Path Identifier is 0 to 255 and the range for the Virtual Circuit Identifier is 32 to 65535 The ATM Forum has reserved VCI identifiers 0 to 31 for control traffic Bridge EOA AAL5 PVC VPI VCI User s Guide Display the number of the PVC profile Display the EOA number of the PVC profile Display ATM Adaptation Layer 5 AAL5 It is used to send variable length packets up to 65 535 octets in ...

Страница 51: ...DSL Port 1 48 PVC 1 8 MPoA Channel Mode Mac Profile Choose the number DSL port to make all the configuration will be applied to the created PVC Use the drop down menu to choose the PVC number Use the drop down menu to choose the data encapsulation method to be used over the AAL5 It is used to select the ADSL physical line mode Fast and Interleaved represent different algorithms for DSL data transm...

Страница 52: ...ofile Display the identification number for this profile Display the MAC address specified for this profile Click this button to create a new MAC profile Click this button to delete the selected MAC profile Creating a Profile Click Create to generate a new VLAN profile Below shows the detailed web page Profile ID Mac Address Type the value as the identification number The range is from 1 to 48 Typ...

Страница 53: ...file Display the name of the VLAN profile Display the egress port value for port 1 port 48 Display the untag port value for port 1 port 48 Display the mode for the selected VLAN used Click this button to modify the existed VLAN profile Click this button to create a new VLAN profile Click this button to delete the selected VLAN profile Creating VLAN Click Create to generate a new VLAN profile Below...

Страница 54: ... any destination address MAC lookup Cross Connect There is no learning and lookup and there are at most two member ports for it The set of ports are permanently assigned to the egress list for this VLAN by management Choose the egress port to be applied under such VLAN profile The set of ports should transmit egress packets for this VLAN as untagged Choose the untag port to be applied under such V...

Страница 55: ...onfiguration and Max Unicast address Bridge Port Display the number of the profiles that system offered 1 48 represents port 1 to port 48 Editing Bridge Profile Click the radio button of the profile you want to edit Next click Edit to open it Below shows the detailed web page 47 User s Guide ...

Страница 56: ...the Leave processing is triggered Fast the port is immediately deleted from that multicast group on Leave message reception and then the Leave message is forwarded Fast Normal the Leave message is forwarded and the Leave processing is triggered immediately without waiting for any trigger from the Querier It determines the process queue that the received frame is mapped to UBR all coming packets ar...

Страница 57: ...with a set of parameters is used to quantify the quality of service provided Serial No Name PCR SCR MBS Edit Display the number of the profiles that system offered 1 48 represents port 1 to port 48 Display the QoS profile name for each port Display the values of UBR nrt VBR rt VBR and CBR for PCR SCR MBS PCR represents Peak Cell Rate SCR represents Sustainable Cell Rat MBS represents Maximum Burst...

Страница 58: ...ium process queue CBR The ratelimit of the highest process queue SCR means Sustainable Cell Rat Values typed here can determine the process queue for the ratelimit of SCR value UBR The ratelimit of the lowest process queue rt VBR The ratelimit of the high process queue nrt VBR The ratelimit of the medium process queue CBR The ratelimit of the highest process queue It means Maximum Burst Size Value...

Страница 59: ...44 19 Yellow brown Brown yellow TIP RING 19 33 8 Red green Green red TIP RING 8 45 20 Yellow gray Gray yellow TIP RING 20 34 9 Red brown Brown red TIP RING 9 46 21 Violet blue Blue violet TIP RING 21 35 10 Red gray Gray red TIP RING 10 47 22 Violet orange Orange violet TIP RING 22 36 11 Black blue Blue black TIP RING 11 48 23 Violet green Green violet TIP RING 23 37 12 Black orange Orange black TI...

Страница 60: ...the change in status The alarm relay connector also provides one set of contacts for audible alarms and one set for visual alarms The maximum contact rating is 30VDC 2A 125VDC 0 5A Pin8 Pin1 The table below lists the pin assignments for backplane connector RJ45 the alarm relay connector A 3 Alarm Port RJ45 Connector RJ45 jets provide connection with an external alarm device to the alarm connector ...

Страница 61: ...r backplane connector RJ45 the alarm relay connector A 4 RS232 Connector The RJ45 connection jet is used for CLI commands for system configurations and controlling functions in the VigorAccess The jet is used for initialization of the VigorAccess during the preliminary installation The management cable as shown in Figure 1 15 converts the RJ45 to the RS232 interface The RJ45 jet connects to a cons...

Страница 62: ...x 6 6 Rx 7 7 8 8 A 5 Standard 10 100 Base T Ethernet Interface Connector RJ45 jets provide 10 100 Base T Ethernet interfaces The interface supports MDI MDIX auto detection of either straight or crossover RJ45 cables These cables are used on UP1 UP2 MGN interfaces At 400 and 600 W the surface roughness was quite low 15 2 and the coatings showed a mirror like surface with a high brightness User s Gu...

Страница 63: ...Base T Ethernet Interface Connector RJ45 jets provide 8P8C 10 100 1000 Base T Ethernet interfaces The interface supports MDI MDIX auto detection of either straight or crossover RJ45 cables These cables are used on GE interfaces for subtending connection on Master and UP1 UP2 MGN port on Slave A 7 Contacting Your Dealer If the device you have still cannot work correctly after trying many efforts pl...