background image

 CAUTION:

 Beware of pinch 

points along closure.

5. 

Swing trap door assembly upward, stopping just before 

latch levers hit bottom flanges of endcaps 

(and center of 

case where appropriate)

.

6. 

Pull latch levers toward center of screen case to allow trap 

door assembly to be pivoted to its closed position.

Please Note:

 Ensure that latch levers engage fully with case 

endcaps 

(and center of case where appropriate)

.

Please Note:

 When locating viewing surface and checking clearance 

for screen operation, ensure that surface is centered in the case.

1. 

Engage each case mounting bracket 

(attached to case)

 with top of 

housing 

(Fig. 2)

 and tighten set screws.

2. 

Screen should be sufficiently supported to withstand vibration.

Please Note:

 A hoisting bracket is included on each end of the case to 

aid in overhead installation.

3. 

Ensure that fasteners are of adequate strength and suitable for the 

mounting surface chosen. Supporting hardware such as chains, 

cables, two 

3/8

(9.5 mm)

 rods, etc., must be 

precisely

 vertical.

4. 

Entire bottom of case must be readily accessible after installation 

is complete.

5. 

Front, back, and top of case must be straight—not forced to warp 

or bow.

Section 2 -

 Hanging Screen

 CAUTION:

 Screen case and flange are not designed to serve as ceiling support.

6. 

Do not seal unit in ceiling until electrical connections have been made and screen 

operates successfully.

Please Note:

 If case is painted on location, removal of roller/fabric assembly is 

recommended prior to painting. If not removed, slot on bottom of case should be 

shielded to protect viewing surface from paint splatters/overspray.

Please Note:

 Extra brackets must be ordered for 

alternate installation.

Section 3 -

  Bottom Access Panel/Trap Door  

Opening and Closing

1. 

To access inside of screen case, disengage spring latch at center, followed by latches 

at each end.

2. 

To disengage, slide latch lever towards center of screen case 

(Fig.3)

, then pull down 

gently on trap door assembly.

Please Note:

 Latch levers are somewhat concealed from view. Locate with trap door 

open by feeling for vertical latch lever above door about 3" 

(76mm)

 from case endcaps 

and near center of case.

3. 

Assembly will swing down and open 

(about 135˚)

.

4. 

Pivot prop arms at each end of trap door assembly. Prop arms will engage with a hole 

in each endcap to hold trap door assembly fully open. To close trap door assembly 

disengage prop arms from endcaps and pivot over access panel.

Figure 3

Figure 4

ACCESS 

DOOR 

LATCH

ACCESS DOOR 

SUPPORT

BRACKET

ACCESS 

DOOR 

LATCH

ACCESS DOOR 

SUPPORT

BRACKET

SLIDE

TRAP DOOR 
(up position)

CASE 

INTERIOR

CASE

MOUNTING

 

BRACKET

⁷�₈

"

(22

MM

)

ELECTRICAL

CUTOUT

HOISTING

 

BRACKET

TYPICAL

INSTALLATION

1

With typical installation, brackets may be 

angled to meet installation requirements. 

Additional set of brackets required 

but NOT included. 

CASE

MOUNTING

 

BRACKETS

HOISTING

 

BRACKET

ALTERNATE

INSTALLATION

CASE

MOUNTING

 

BRACKET

⁷�₈

"

(22

MM

)

ELECTRICAL

CUTOUT

HOISTING

 

BRACKET

TYPICAL

INSTALLATION

1

With typical installation, brackets may be 

angled to meet installation requirements. 

Additional set of brackets required 

but NOT included. 

CASE

MOUNTING

 

BRACKETS

HOISTING

 

BRACKET

ALTERNATE

INSTALLATION

Figure 2

page 3 of 7

Ultimate Access E and V 220V

Содержание Ultimate Access E

Страница 1: ...pping Brackets Attached to Dowel and Screen Case V Screens Only Please Note Shipping brackets must remain in place until product has been mounted and connected to power see Sections 1 and 4 in this document Also DO NOT operate screen before removing shipping brackets from screen case TOOLS REQUIRED POWER DRILL PENCIL TAPE MEASURE HARDWARE by others LEVEL E Free Hanging Viewing Surface V Flexible V...

Страница 2: ... and normal operation Extreme care should be taken during testing to remain clear of moving parts to avoid possible injury 12 Operation of unit should be performed only by authorized and qualified personnel who have been trained in its safe and effective operation and understand its safety features 13 The safety features of the unit should never be disabled bypassed or overridden The system should...

Страница 3: ...lot on bottom of case should be shielded to protect viewing surface from paint splatters overspray Please Note Extra brackets must be ordered for alternate installation Section 3 Bottom Access Panel Trap Door Opening and Closing 1 To access inside of screen case disengage spring latch at center followed by latches at each end 2 To disengage slide latch lever towards center of screen case Fig 3 the...

Страница 4: ...ges with motor If retaining clip is provided instead install to lock motor end in place 7 Support idler end of roller and slide mounting bracket toward roller Insert roller pin into nylon bushing on idler bracket Fig 7 8 Roller idler pin goes through idler bracket Reinstall washer and retaining clip CAUTION Failure to replace washer and retaining clip could result in separation of roller from brac...

Страница 5: ...key PUSH TURN CLOCKWISE to INCREASE TENSION PUSH TURN COUNTER CLOCKWISE to RELEASE TENSION END OF DOWEL END OF DOWEL Figure 8 Section 9 Limit Adjustments Figure 10 Figure 9 Down Limit Adjustment requires 5 32 4 mm Hex key To Reduce Screen Drop 1 Raise screen surface approximately 1 30 cm above desired setting and turn off 2 Turn DOWN I limit screw clockwise 3 screw turns 1 2 roller revolution 3 Te...

Страница 6: ...NGTH Standard Motor Wiring is on the AUDIENCE LEFT END of Screen Case 7 187mm 6 171mm 8 203mm For minimum length of ceiling cutout subtract 11 4 32mm from case length measured from outer edge of flanges For minimum width of cutout front to back see case width dimensions below Leveling bracket is used to level the case and should NOT be used to support the weight of the unit The leveling bracket is...

Страница 7: ...hed IR Eye Input Low Voltage Trigger 4 28 VDC RS232 485 Inputs Outputs Receiver Button Wall Switch Green Yellow Motor Ground FUSE 3 15 AMP 250 VAC 5x20mm External LVC IV Single or Multiple Projection Screen Wiring Diagram FUSE 3 15 AMP 250 VAC 5x20mm Receiver Button 3 Button Wall Switch DOWN Black COM White UP Red Electrically Straight Data Cable to more LVC IV modules A maximum of six 6 LVC IV mo...

Отзывы: