background image

 WARNING   

Improper installation and use of the Ultimate Access Projection Screen can result in serious injury or death. Primarily, injuries can occur if the unit 

falls due to imprecise installation, mishandling of the unit during installation, or installation on an insufficient wall or ceiling structure.  

Please use extreme care.
1. 

Please read the following installation guidelines thoroughly and follow them 

carefully. Failure to do so may cause product to fall or otherwise fail, and 

could result in serious injury.

2. 

Installation and calibration of the unit should only be performed by an 

authorized, qualified, and experienced professional. In particular, electrical 

work and wiring [indicated in diagram by dashed lines] must be completed 

only by a qualified professional electrician who has read this manual 

completely and is familiar with the construction and operation of this 

equipment and the hazards involved.

3. 

Do not affix the unit to walls or ceilings that have inadequate strength 

to permanently hold the unit during use. It is the owner’s and installer’s 

responsibility to confirm the wall or ceiling to which the unit attaches is 

sufficient to permanently hold the weight and stress loads of the unit at all 

times. Draper, Inc., is not responsible for improper installation, application, 

testing, or workmanship related to the product at place of installation.

4. 

It is the installer’s responsibility to make sure appropriate fasteners are used 

for mounting.

5. 

All hardware must be installed level. Unit must be level and square.

6. 

Never leave the area while operating the unit during installation, maintenance, 

or normal operation, unless it is secure and safe.

7. 

Before testing or operation, carefully inspect the entire area and path 

(especially underneath)

 of unit to be sure no persons or objects are in the area.

8. 

Turn off power and any nearby equipment or cables carrying electricity 

before connecting switches, wires, controls, or electrical components.

9. 

Do not wire motors in parallel without written permission from Draper, Inc.

10. 

During testing or operation, carefully watch the surrounding area for any 

potential safety concerns including nearby persons or objects.

11. 

After installation, the entire system, including all sensors, should be carefully 

tested to ensure safe and normal operation. Extreme care should be taken 

during testing to remain clear of moving parts to avoid possible injury.

12. 

Operation of unit should be performed only by authorized and qualified 

personnel, who have been trained in its safe and effective operation and 

understand its safety features.

13. 

The safety features of the unit should never be disabled, bypassed, or 

overridden. The system should not be operated until all safety features are 

properly and completely installed, calibrated, and tested.

14. 

Unit may need to comply with local, state, or district rules and regulations, 

in particular when installed in schools. All applicable rules and regulations 

should be reviewed before installation and use.

15.  Failure to precisely follow installation guidelines invalidates all 

warranties.

16. 

Custom products/installations may not be reflected in this manual. Call 

Draper, Inc., if you have questions about the installation of custom products 

or any questions about your installation.

Before Beginning Installation

1. 

Look for any job site conditions that could interfere with installation or 

operation of the system.

2. 

Read carefully and be sure to understand all installation instructions and 

all related operations manuals. These instructions are intended to serve 

as a guide for the installer and owner. They should be followed closely and 

combined with the expertise of experienced qualified installers. Draper, 

Inc., is not responsible for improper installation, application, testing, or 

workmanship related to the product at place of installation. Please retain all 

instructions for future use.

3. 

Open cartons lengthwise.

4. 

Locate and lay out all pieces.

5. 

Inspect all boxes to make sure you have received the proper unit and parts. 

Controls may be shipped separately, or in same carton as unit.

6. 

If you have any difficulties with installing, servicing, or operating your unit, 

call your dealer or Draper, Inc., 765-987-7999.

Important Safety Information

Important Safety Information

PLEASE READ -

 Safety Information

Remove 

fasteners from 

bracket clamps.

Run screen

DOWN to expose 

dowel screws. 

Loosen screws  

and remove 

shipping bracket.

Retighten 

dowel endcap 

screws.

Section 1 -

  Removing Shipping Brackets 

(Tab-Tensioned, "V" Surfaces only)

 CAUTION:

 DO NOT remove shipping 

brackets until product has been 

mounted and connected to power 

(see 

Section 4 in this document.)

.  

Also, DO NOT OPERATE SCREEN 

BEFORE REMOVING SHIPPING 

BRACKETS FROM SCREEN CASE.

page 2 of 7

Ultimate Access E and V 220V

Содержание Ultimate Access E

Страница 1: ...pping Brackets Attached to Dowel and Screen Case V Screens Only Please Note Shipping brackets must remain in place until product has been mounted and connected to power see Sections 1 and 4 in this document Also DO NOT operate screen before removing shipping brackets from screen case TOOLS REQUIRED POWER DRILL PENCIL TAPE MEASURE HARDWARE by others LEVEL E Free Hanging Viewing Surface V Flexible V...

Страница 2: ... and normal operation Extreme care should be taken during testing to remain clear of moving parts to avoid possible injury 12 Operation of unit should be performed only by authorized and qualified personnel who have been trained in its safe and effective operation and understand its safety features 13 The safety features of the unit should never be disabled bypassed or overridden The system should...

Страница 3: ...lot on bottom of case should be shielded to protect viewing surface from paint splatters overspray Please Note Extra brackets must be ordered for alternate installation Section 3 Bottom Access Panel Trap Door Opening and Closing 1 To access inside of screen case disengage spring latch at center followed by latches at each end 2 To disengage slide latch lever towards center of screen case Fig 3 the...

Страница 4: ...ges with motor If retaining clip is provided instead install to lock motor end in place 7 Support idler end of roller and slide mounting bracket toward roller Insert roller pin into nylon bushing on idler bracket Fig 7 8 Roller idler pin goes through idler bracket Reinstall washer and retaining clip CAUTION Failure to replace washer and retaining clip could result in separation of roller from brac...

Страница 5: ...key PUSH TURN CLOCKWISE to INCREASE TENSION PUSH TURN COUNTER CLOCKWISE to RELEASE TENSION END OF DOWEL END OF DOWEL Figure 8 Section 9 Limit Adjustments Figure 10 Figure 9 Down Limit Adjustment requires 5 32 4 mm Hex key To Reduce Screen Drop 1 Raise screen surface approximately 1 30 cm above desired setting and turn off 2 Turn DOWN I limit screw clockwise 3 screw turns 1 2 roller revolution 3 Te...

Страница 6: ...NGTH Standard Motor Wiring is on the AUDIENCE LEFT END of Screen Case 7 187mm 6 171mm 8 203mm For minimum length of ceiling cutout subtract 11 4 32mm from case length measured from outer edge of flanges For minimum width of cutout front to back see case width dimensions below Leveling bracket is used to level the case and should NOT be used to support the weight of the unit The leveling bracket is...

Страница 7: ...hed IR Eye Input Low Voltage Trigger 4 28 VDC RS232 485 Inputs Outputs Receiver Button Wall Switch Green Yellow Motor Ground FUSE 3 15 AMP 250 VAC 5x20mm External LVC IV Single or Multiple Projection Screen Wiring Diagram FUSE 3 15 AMP 250 VAC 5x20mm Receiver Button 3 Button Wall Switch DOWN Black COM White UP Red Electrically Straight Data Cable to more LVC IV modules A maximum of six 6 LVC IV mo...

Отзывы: