220V Silhouette/Series E & V by Draper 

Page 5 of 5

www.draperinc.com

(765) 987-7999

ILT Switch-to-Motor—Dry Contacts or Data Cable connection

Please Note: 

This Splitter/

Jack is located inside the junc-
tion box of your screen.

Back of wall switch.

Please Note: 

Although both 

Dry Contact and Data Cable 
connections are shown, you 
should only use one connec-
tion type per motor.

Data Cables to switches or 

to additional motors can 

be plugged into any of the 

three open jacks. If this is a 

"Case First, Screen Later" 

installation, plug the motor 

cable into the jack indicated 

in the drawing.

Please Note: 5V DC must be 

connected to be able to set 

limits using the wall switch.

See separate Serial Communica-
tion-RS232 Instruction sheet for 
enabling RS232 with the MC1.

3 Button Wall Switch  

DOWN - Black 

COM - White 

UP - Red 

White or Blue-Common to screen & 110/220V AC Neutral

Red-to screen (directional)

Brown-to screen (directional)

Yellow-to 110/220V AC-Hot

Black-to 110/220V AC-Hot

Green/Yellow (Ground)

Eye Port

 for IR Eye, RF Receiver or LED 

Wall Switch. For more than one of  

these, a splitter is required. 

Aux Port 

for connecting additional LVC-III  

modules (up to six total can be linked- 

connect from Aux to Eye). 

 

Dashed wiring by electrician 

Low voltage wiring by others 

White/Blue (Common)

Red 110/Black 220 (Up)

Black 110/Brown 220 (Down)

Location of key 

operated on-off  

switch if furnished 

To

110/220V

Line

Internal Screen Wiring 

 

STOP 

Control  

Switches 

24v DC 

STOP 

Green/Yellow

(Motor Ground)

RS232 Data FROM Control System 

RS232 Data TO Control System 

Signal Ground & Manual Switch Common 

Manual Switch Down 

Manual Switch Up 

White or Blue-Common

Red-to Screen (directional)

Black-to Screen (directional)

Brown-Hot to AC

Green/Yellow-Ground

Fuse 

Program LED 

Eye Port for IR Eye. For RF Receiver or LED 

Wall Switch, a Splitter and a Power Supply 

is required. Plug RF Receiver or LED Wall  

Switch and Power Supply into splitter, then  

run cable from Splitter to MC1 Eye Port. 

Low Voltage Wiring by others 

AC Wiring by electrician 

MC1 

Location of key 

operated on-off  

switch if furnished 

To AC Line 

White/Blue (Common)

Red 110/Black 220 (Up)

Black 110/Brown 220 (Down)

Internal Screen Wiring 

 

Green 110V/

Green/Yellow 220V

(Motor Ground)

External Low Voltage & Wireless Control

Two-Way Serial Communication (RS232) with MC1

 Wiring Diagram for Optional, Built-in Video Interface Control

Built-in Video Interface Control

Junction box at 
left end of screen

Internal screen wiring

Blue (Neutral)

Black (Hot)

Green/Yellow (Ground)

Dashed wiring 
by electrician

220 VAC supply

Trigger signal

VIC220 (220 VAC, white cord & plug)

VIC12 (12 VDC, brown & orange leads)

N

L1

INSERT MOTOR DATA 
CABLE HERE

Отзывы: