Draper Silhouette E series Скачать руководство пользователя страница 2

Silhouette/Series E & V by Draper 

Page 2 of 5

Removing Case Fascia

Caution: When removing or reattaching fascia, do not handle fascia 

by unpainted ends.

Case fascia is removable to access roller assembly. To remove fascia, depress 

outward the spring lip located inside lower front corner of screen case and 

pull lower corner of fascia outward. Repeat this at right end of case. Support 

fascia from center and rotate lower front edge upward approximately 40° to 

disengage the Roll-Lok  hinge at the top front of screen case. Fascia can now 

be completely removed from case.
To install fascia, generally reverse instructions above making sure the Roll-

Lok hinge is completely engaged before rotating fascia down towards the 

closed position. Depress spring clips outward, push lower corners of fascia 

inward until lips of spring clips hook behind fascia.

Please Note: Be sure the clips are completely up against the ends of the 

fascia.

Electrical Connections

Screen operates on 110-120V, 60 Hz., 1.1 amp current draw. Duty Cycle: ON 

28 seconds/OFF 4 minutes.
Junction box is located at left end of screen. It is accessible through front 

of screen case after fascia is removed (see instructions above for removing 

fascia).
Electrical supply wires can enter through the back or top of case. For top 

entry, remove plug from top conduit hole and snap plug into hole on back side 

of case.
Junction box contains red, black, and white pigtail leads and green internal 

ground wire per wiring diagram attached.
If optional low voltage control or video interface control is specified, please 

refer to wiring diagrams on pages 4-5.
Wall or ceiling electrical box should be installed so as to be fully concealed by 

screen case after installation.
Screen is shipped with internal wiring complete and control switch(es) fully 

boxed. Wire to connect screen to switch(es) and switch(es) to power supply 

should be furnished by installer. Please Note: Screen must be installed in 

accordance with the requirements of the Local Building Codes, the Cana-

dian Electrical Code (CEC), CAN/CSA C22.1 and the National Electric Code 

(NEC), NFPA 70. An appropriate disconnect device shall be provided as part 

of the building installation.

All operating switches should be “off” before power is connected.

Plug-in power cord option available on units with built-in low voltage controller.

  For Reconfiguration/Conversion of Non-detachable Power Cord to 

Field Wiring for Models SLE-28, SLE-30, SLV-28 and SLV-30 Only:

1

  Disconnect cord plug from outlet.

2

  Remove junction box cover.

3

  Disconnect wire nut connections from black, white and green wires.

4

  Remove power cord and strain relief.

5

  Connect the black from motor to "hot" supply wire.

6

  Connect white wire from motor to "neutral" supply wire.

7

  Connect green/yellow ground to "ground" supply wire.

8

  Replace junction box cover.

Operation

Before operating screen, remove any shipping brackets or tape securing fab-

ric and dowel to the roller. If viewing surface hangs out of case 8" or 9", tape 

has probably been broken by rough handling in shipment, allowing surface to 

“unwrap” one turn off the roller. Manually wrap fabric back around the roller 

without turning the roller itself.
When screen is first operated, 

be cautious! 

Cycle unit down and up several 

times to confirm satisfactory operation.

110-120V SINGLE STATION CONTROL—

3-position UP-OFF-DOWN switch 

permits operation to be stopped at any point. Factory adjusted limit switches 

automatically stop screen when fully down or fully up.

110-120V MULTIPLE STATION CONTROL

—Switches are similar in ap-

pearance to 110-120V Single Station Control. Screen stops when switch 

is released and may be restarted in either direction. Factory adjusted limit 

switches stop screen automatically when fully down or fully up.

24V MULTIPLE STATION CONTROL

—Three-button UP-STOP-DOWN 

switches stop at any point desired, operate in any sequence. Factory adjusted 

limit switches automatically stop screen when fully down or fully up.

110-120V & 12V VIDEO INTERFACE CONTROL

—Allows screen to be con-

trolled by a trigger signal—when the signal comes on, the screen descends 

automatically. Two versions: Model VIC115 integrates screen operation with 

a DRAPER video projector lift or a video projector or tuner with a 110-120V 

switch outlet. Model VIC12 interfaces with a 12V switch outlet. Both available 

with an override switch (VIC–OS), permitting independent operation. VIC–OS 

not available with factory installed VIC115 & VIC12. 

KEY OPERATED SWITCHING

—Two kinds of key-operated switches are 

optionally available with this unit.

1

  The key-operated power supply switch controls power to the screen and  

  switches. When it is “off”, the switches will not operate screen.  

  Key may be removed from the switch in either “on” or “off” position.

2

  A three-position key switch permits the screen to be operated directly by  

  key. In this case, the screen’s operator must always have a key.

RS232/ETHERNET

Serial communication and network communication 

optionally available with wall switches, RF or IR remote.

PLUG & PLAY

TM

Provided with handheld IR remote control transmitter and 

10' (3m) cord. No wiring necessary except to connect to RS232. Screen is 

equipped with a handheld remote or 3-position operating switch (see below). 

Three positions (up-off-down) permit operation to be stopped at any point. 

Factory adjusted limit switches automatically stop screen when fully down or 

fully up.

Limit Adjustments—Standard Motor

 

Please Note: Screen limits are factory set for optimum performance of 

the screen. A procedure is outlined below for minor tweaks, but any ad-

justment of these limits may negatively affect the flatness of the screen 

surface and could also void the warranty. Please check with Draper prior 

to resetting screen limits.

CAUTION: Always be prepared to shut screen off manually when new 

adjustment is being tested. Screen may be severely damaged if viewing 

surface is allowed to run too far up or too far down.

C

AUTION: Be sure all switches are in “off” position before adjusting 

limit switches.

  The motor limit screws are normally located on the audience left of screen 

roller.

www.draperinc.com

(765) 987-7999

Extension Wall Brackets

6" or 10"-14" Extension Wall Brackets are needed to mount Silhouette 

extended from wall. Wall Brackets are not supplied with screen and must be 

ordered separately. Specify “Silhouette Extension Wall Brackets”. 

1

  Mount the Wall Brackets to the wall, making sure they are level and verti- 

  cally plumb. Installer must insure fasteners (not included) are of adequate  

  strength and suitable for chosen mounting surface.

2

  Attach hanging bracket to wall bracket as shown. 

3

  Attach (1) “Z” Clip and (1) Support Plate (supplied with screen) to hanging  

  bracket as shown.

4

  Engage the lip on back of screen case with lip of “Z” Clip and gently pull  

  down to fully engage case to brackets. 

5

  Install hook bracket as shown making sure the two tabs of this bracket  

  hook over the case extrusion.

6

  Install #10-24 hex head screw through hook bracket, hanging bracket, and  

  support plate as shown.

Hook

Bracket

CB ¼"-20 x 1¾" Z Keg,

Flat Washer,

¼"-20 Nylock Nut

#10-24 x 

7

/

8

"

Phillips Pan Head

Screw, Nylock Nut

#10-24 x ½"

Hex Head Screw

Z Clip

Wall

Bracket

Support

Plate

Hanging

Bracket

Отзывы: