![Draper Ropewalker Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/draper/ropewalker/ropewalker_instructions-installation-and-operation_2528526004.webp)
Standard Control Switch
(SS-1R)
Single switch requires a standard switch
box that measures 3"
(76mm)
high x 2¼"
(57mm)
wide x 2½"
(64mm)
deep. Install
optional control switch in accordance with
wiring diagram
(Fig. 4)
.
Please Note:
For 220V Single Station
Wiring see Page 8.
Low-Voltage Contact Closure Control Wiring
See wiring diagram at left.
1.
Remove strain relief from the Low-Voltage Controller and replace with electical
conduit.
2.
Connect Low-Voltage Controller to motor in accordance with wiring diagram.
3.
If RF Remote included, program frequency of receiver by following steps below.
Please Note:
For 220V Low-Voltage Wiring see page 8.
Single Station Control
White
(Common)
Brown
(Down)
Red
(Up)
Black
(L1)
Grn/Ylw
(Ground)
Dashed wiring
by electrician
Control
switch
Single gang box
(by others)
(102x54x48mm)
Blue
Black
Red
Location of key
operated on-off
Min. 4" x 2
1
/
8
" x 1
7
/
8
" deep
switch
(if furnished)
N L1 To 110-120V Line
Internal Screen Wiring
Location of key
operated on-off
switch
(if furnished)
To 110-120V Line
Low-Voltage Control for 110V Ropewalker
Red
Black
White
Black
(L1)
Grn/Ylw
White
(N)
Red
(Up)
Brown
(Down)
White
(Common)
Black
(L1)
Grn/Ylw
(Ground)
Dashed wiring
by electrician
Low-Voltage Wiring
Ropewalker Wiring
Blue
Black
Red
L1
NEU
GND
Com
Down
Up
2 3 4 5 6 7
1
1
1
7
6
3
2
5
4
2
1
7
6
3
2
5
4
3
1
7
6
3
2
5
4
4
1
7
6
3
2
5
4
5
1
7
6
3
2
5
4
6
1
7
6
3
2
5
4
7
1
7
6
3
2
5
4
8
7
6
5
2 3
1
4
9
7
6
3
2
1
4 5
10
7
6
3
2
1
4 5
11
7
6
3
2
1
4 5
12
7
6
3
2
1
4 5
13
7
6
5
3
2
1
4
14
15
7
6
5
3
2
1
4
21
7
6
5
3
2
4
1
22
7
6
5
3
2
4
1
24
7
6
5
3
2
4
1
25
7
6
5
4
1
3
2
23
7
6
5
3
2
4
1
16
7
6
5
3
2
1
4
17
7
6
5
4
2 3
1
18
7
6
5
3
2
4
1
19
7
6
5
3
2
4
1
20
7
6
5
3
2
4
1
Hole
Plug
Terminal
Strip Inside
Dipswitch
Access
Cover
Programming RF Receiver Frequency
1.
Open dip switch cover on end of Low-Voltage Controller
(Fig. 5)
. Cover opens by loosening outer screw and rotating cover.
2.
Locate the dip switch bank inside receiver and set the dip switches per the following chart, then close dip switch access
cover. A switch is in ON when in the down position
(toward the mounting plate)
.
Attaching Optional Key Switch or Contact Closure Control to Low-Voltage Control
Low-Voltage Control Receiver is capable of having dual methods of operation.
It is possible to attach an optional Low-Voltage backup key switch, in addition to being operated with
an optional 99-Station RF Transmitter.
To connect the optional key switch, pull a three-conductor control wire between the switch location
and the Low-Voltage Control. The connections between the key switch and the terminal block
(located
on the outside of the receiver housing)
should be made per Figure 6.
Key or contact closure must be held closed to operate Ropewalker to lower limit or closed position.
Section 5 -
Ropewalker Wiring
Figure 4
Figure 5
Figure 6
page 4 of 8
Ropewalker