Rolleramic Wiring Diagrams
Conduit
connection
L = W+24" (through 12' x 12')
L = W+30" (over 12' x 12')
Through 12' x 12' 14¾"
Over 12' x 12' 21¼"
Access
Door
Bottom board
Case
¾" thick
4" - 4
1
/
8
"
Opening for fabric
Bottom
Front
Fabric width – W
Screen
surface
4
5
/
8
"
9
1
/
8
"
9
1
/
8
"
9
5
/
8
"
9
5
/
8
"
11
1
/
2
"
1"-6" from
access door
6"-12" from
case edge
Page 2 of 2
Case Dimensions
Rolleramic by Draper
Rolleramics over 12' x 12'
have a blue wire lead
instead of a black wire lead
coming from the motor.
Single Station Control
Junction box at
left end of screen
Internal Screen Wiring
White (Common)
Red (Down)
Black, or Blue (Up)
Green (Ground)
Dashed wiring
by electrician
Control
switch
Single gang box by others
Min. 4" x 2 1/8" x 1 7/8" deep
Blue
Black
Red
Location of key
operated on-off
switch if furnished
To 110-120V Line
Multiple Station Control
Junction box at
left end of screen
Internal Screen Wiring
White (Common)
Red (Down)
Black, or Blue (Up)
Green (Ground)
Dashed wiring
by electrician
Red
Red
Black
Blue
Blue
Cap off with wire
nut and tape
Black
Red
Blue
Black
Single gang box by others
Min. 4" x 2 1/8" x 1 7/8" deep.
3 shown. More or less equally
feasible.
Location of key
operated on-off
switch if furnished
To 110-120V Line
For suspended mount.
For wall mount
6
3
/
8
"
1
3
/
8
"
Rolleramic Mounting Bracket
www.draperinc.com
(765) 987-7999
IR Eye Input
Low Voltage
Trigger
3-28 VDC
RS232/485
Inputs/Outputs
Receiver
Button
3 Button Wall Switch
DOWN - Black
COM - White
UP - Red
Wall Switch
Electrically Straight
Data Cable to more
LVC-IV modules*
*A maximum of six (6)
LVC-IV modules can be
linked together.
FUSE - 3.15 AMP
250
VA
C 5x20mm
Dashed wiring by electrician
Low voltage wiring by others
To
110-120 VAC
Line
Red-to screen (directional)
Brown-to screen (directional)
Yellow-to 110V-220V AC-Hot
Black-to 110V-220V AC-Hot
White -Common to screen & 110V-220V AC Neutral
Green/Yellow (Ground)
White (Common)
Red (Down)
Black (Up)
INTERNAL SCREEN WIRING
Green/Yellow
(Motor Ground)
N
L1
GND
Location of key
operated on-off
switch if furnished.
External LVC-IV - Single or Multiple
Wiring Diagram for Ambassador and Rolleramic
Low Voltage & Wireless Control
Please Note: Mount the case using the two end brackets first. If
a center bracket is provided, mount it last. The center bracket is
designed to prevent sagging of the case, and must be mounted so
that it is level with the others and does not force the screen case
up. Make sure the top of the screen case's bottom board at no
point touches the roller/viewing surface.
Screens through 14' wide have 2 mounting
brackets; wider screens have 3. Brackets
should be located along case to line up
with supporting beams or studding. Motor
end bracket must be located 1"-6" to right
of access door. Idler end bracket must
be located 6"-12" from right end of case.
Failure to mount brackets as directed could
cause case to bow and result in damage
to screen.
Please Note: Do not wire motors in parallel.