Draper Rolleramic Скачать руководство пользователя страница 1

Copyright © 2015 Draper Inc. Form Rolleramic_Inst15 

Printed in U.S.A.

Wall Installation—

Brackets should fasten to studding or other structural supports within wall.

Suspended Installation—

Chains should be attached to solid beams or rafters above screen. If possible, 

screen mounting brackets should be positioned so chains hang vertically. 

Turnbuckles should be connected between chains and mounting brackets. After 

screen has been suspended, turnbuckles should be adjusted so that screen hangs 

level.

Recessed Installation—

Recess should be constructed to fit screen case with brackets (see “Case 

Dimensions” on back page). Design recess so that entire bottom of screen case 

is unobstructed to permit access to bottom panel, screen roller and surface for 

servicing if required.

Hanging Screen 

General:

When locating viewing surface and checking clearance for screen operation, 

remember surface is not centered in screen case: see dimensional drawings on 

reverse. All installations should observe these important criteria:

1

 Screen should be positively and securely supported so that vibration or even  

  abusive pulling on viewing surface will not weaken installation.

2

 Installer must insure that fasteners used are of adequate strength and suitable  

  for the mounting surface.

3

 Entire bottom of case must be readily accessible after installation is complete.  

  Be sure the access door opens freely for adjustments and service.

4

 Installer should make sure mounting brackets are flush with the sides of the  

  case to provide stability when hanging screen. 

Keep case level when lifting 

  and mounting.

5

 Screens through 14' wide have 2 mounting brackets; wider screens have 3.  

  Brackets should be located along case to line up with supporting beams or  

  studding. Motor end bracket must be located 1"-6" to right of access door. Idler  

  end bracket must be located 6"-12" from right end of case. Failure to mount  

  brackets as directed could cause the case to bow and result in damage to screen.

Please Note: Mount the case using the two end brackets first. If a center 

bracket is provided, mount it last. The center bracket is designed to prevent 

sagging of the case, and must be mounted so that it is level with the others 

and does not force the screen case up.

6

 Make sure the top of the screen case's bottom board at no point touches the  

  roller/viewing surface.

7

 Do not use screen case to support adjacent sections of ceiling.

8

 If trim pieces must be attached to case, do not permit screws to pro trude  

  through ¾" wall of case. Do not attach trim with nails.

9

 If case is painted, viewing surface slot must be shielded to protect viewing  

  surface from paint splatters and overspray.

10

 Do not seal unit in ceiling until electrical connections have been made and  

  screen has been operated successfully. Screen must always be installed level  

  so that fabric will not roll incorrectly or wrinkle.

These instructions are meant as a guide only. They do not imply any responsibility 

on the part of Draper, Inc. for improper installation or faulty workmanship at the 

jobsite.

Installation/Operating Instructions

Rolleramic Electric Projection Screen by Draper

Electrical Connections

Screen operates on 110-120V, 60 hz. AC, .78 amp draw (1.35 with heavy duty 

motor).

Screens are shipped with internal wiring complete, with all switches (fully boxed) 

and a wiring diagram. Wire connecting screen to switch (or switches) and switch to 

power supply should be supplied by installer. Wires should be connected following 

the wiring diagram provided, and all wiring should comply with local and national 

electrical codes.

All operating switches should be “Off” before power is connected.

Operation

Remove all packing before attempting to operate screen. When screen is first  

operated, be cautious! Cycle unit down and up several times to confirm 

satisfactory operation.

110-120V Single Station Control — 3-position up-off-down switch permits 

operation to be stopped at any point. Factory adjusted limit switches automatically 

stop screen when fully down or fully up.

110-120V Multiple Station Control — Switches are similar in appearance to 110-

120V Single Station Control. Screen stops when switch is released and may 

be restarted in either direction. Factory adjusted limit switches stop screen 

automatically when fully down or fully up.

24V Control — Three-button up-stop-down switches stop at any point desired, 

operate in any sequence. Factory adjusted limit switches automatically stop screen 

when fully down or fully up.

Key Operated Switching — Two kinds of key-operated switches are optionally 

available with this unit.

1

 The key-operated power supply switch controls power to the screen and  

  switches. When it is “off”, the switches will not operate screen. Key may be  

  removed from the switch in either “on” or “off” position.

2

 A three-position key switch permits the screen to be operated directly by key. In  

  this case, the screen’s operator must always have a key.

RS232/Ethernet—Serial communication and network communication optionally 

available with wall switches, RF or IR remote.

Adjustments 

Please Note: Screen limits are factory set for optimum performance of the 

screen. A procedure is outlined below for minor tweaks, but any adjustment 

of these limits may negatively affect the flatness of the screen surface and 

could also void the warranty. Please check with Draper prior to resetting 

screen limits.

CAUTION: Always be prepared to shut screen off manually when new 

adjustment is being tested. Screen may be severely damaged if viewing 

surface is allowed to run too far up or too far down.

C

AUTION: Be sure all switches are in “off” position before adjusting limit 

switches.

CAUTION: Do not loosen coupling setscrews from the roller shaft, or the 

screen surface will rapidly unroll and fall. If setscrew must be loosened 

actions should be taken to prevent the roller from turning.

Adjusting “fully up” position — “Up” limit switch is located on right side of 

limit switch assembly, immediately behind access door to case. Right hand, hex 

head machine screw contacts limit switch button to shut screen off. Turning this 

machine screw clockwise will allow surface to run farther up into case. Turning it 

counterclockwise will cause screen to stop sooner, farther out of the case.

Adjusting “fully down” position — “Down” limit switch is located on left side of 

limit switch assembly, immediately behind access door to case. Left hand, hex 

head machine screw contacts limit switch button to shut screen off. Turning this 

machine screw clockwise will allow surface to run farther down before stopping. 

Turning it counterclockwise will cause screen to stop in a less extended position. 

At no time should fabric be unrolled far enough to expose any part of screen roller. 

Make all adjustments in small increments, and be sure nut on machine screw is 

tight against steel limit switch support before closing access door.

 

 

 

 

Caution

1

  Read instructions through completely before proceeding.

2

  Follow instructions carefully. Installation contrary to instructions invalidates  

 warranty.

3

  Do not lift case in center. Lift the ends simultaneously to avoid damage to  

  case and surface.

4

  Entire bottom of screen case should be unobstructed to permit access to  

  bottom panels for making electrical connections or servicing. Motor end  

  bracket must be located 1"-6" to right of access door. Idler end bracket must  

  be located 6"-12" from right end of case. Failure to mount brackets as directed  

  could cause the case to bow and result in damage to screen.

5

 

Keep case level when lifting and mounting. Screen should be installed  

  level (using a carpenter’s level).

Nothing should be fastened to screen dowel or viewing surface.

Do not touch screen while in motion.

8

  Operating switch (es) packed separately in screen carton. Do not discard  

  with packing material.

9

  Screen operates on 110-120V, 60 hz., .78 amp draw (1.35 with heavy duty motor).

NOTE

: Screen has been thoroughly inspected and tested at factory and found  

to be operating properly prior to shipment.

Universal Mounting Bracket

may be suspended from above,

or mounted to wall. Each bracket

consists of a front and back piece 

bolted together. 2 supplied on

screens up to 14' x 14'. 

3 supplied on larger screens.

Case

Conduit connection

on left end of case.

Viewing Surface

If you encounter any difficulties installing or servicing your Rolleramic screen, call your 

dealer or Draper, Inc., Spiceland, Indiana, (765) 987-7999, or fax (765) 987-7142.

Please Note: The Rolleramic is not available with the TorkStar Utility Line Set.

Motor end bracket must be located 1"-6" to right of access door. Idler end 

bracket must be located 6"-12" from right end of case. Failure to mount brackets 

as directed could cause the case to bow and result in damage to screen.