Section 8 -

 Limit Adjustments 

(Standard Motors)

"Down" Limit Adjustment 

(requires 

5/32

" (4mm) Allen wrench)

To Reduce Screen Drop:

1. 

Raise screen surface approximately 1' 

(30cm)

 above desired setting and turn 

off.

2. 

Turn DOWN 

(I)

 limit screw clockwise 

(3 screw turns = 

1/2

 roller revolution)

.

3. 

Test by lowering screen. Repeat steps 1 & 2 until desired position is reached.

To Increase Screen Drop:

1. 

Lower screen to down limit.

2. 

With down switch on, turn DOWN 

(I)

 limit screw counterclockwise  

(3 screw turns = 1/2 roller revolution) 

to increase drop.

3. 

Test by raising screen approximately 1' 

(30cm)

 then lower to new down limit.

4. 

Repeat steps 2 and 3 until desired position reached.

Please Note:

 For Quiet Motor with alternate limit screws:  

WHITE screw = UP and RED screw = DOWN. 

(Fig. 10)

.

Figure 7

 CAUTION:

- Be sure all switches are in “off" position before adjusting limit switches.
- Be prepared to shut off manually while testing.
- Screen may be damaged by lowering it too far and exposing roller.
- Motor must be installed so that limit switches are pointed down.

Left hand motor:

   White Socket—Down

   Yellow Socket—Up

Right hand motor:

   White Socket—Up

   Yellow Socket—Down

Left hand motor:

   White Socket—Up

   Yellow Socket—Down

Right hand motor:

   White Socket—Down

   Yellow Socket—Up

Left hand motor:

  White Socket—Down

  Yellow Socket—Up

Right hand motor:

  White Socket—Up

  Yellow Socket—Down

Waterfall Roll

Standard Roll

Motor

End

Audience

Side

Motor

End

Audience

Side

Reverse Roll

Motor

End

Back

Side

 CAUTION:

 DO NOT allow dowel to wrap over roller when operating screen!  

This could damage screen.

Figure 6

Please Note:

 Screen limits are factory set for optimum performance. Any 

adjustment of these limits could void the warranty. Please check with 

Draper prior to resetting screen limits.

Please Note:

 If Screen is “Right Hand Motor" the WHITE/DOWN 

(I)

 and 

YELLOW/UP 

(II)

 limit screws are reversed 

(Fig. 7)

.

lI

I

+

+

DOWN Limit (I)

Clockwise decreases 

down 

travel.

UP Limit (II)

Counterclockwise

increases 

up 

travel.

DOWN Limit

 

(I)

Clockwise 

decreases  

down

 travel.

UP Limit 

(II)

Counterclockwise 

increases 

up

 travel.

Section 7 -

 Electrical Connections

 CAUTION:

 All operating switches should be "off" before power is connected. Plug-in power cord option available with built-in low-voltage motor.

• 

Screen operates on 220V 

AC, 50 Hz. or 60 Hz., 

.55 Amp, 1 ph. current 

draw. Duty cycle: On 28 

seconds/Off 4 minutes.

• 

Junction box is located inside left 

endcap and cover plate secures to 

endcap with two screws which may 

be removed with star key or small 

flat head screwdriver. Junction box 

contains red, black, and white pigtail 

leads and green internal ground 

wire, per wiring diagram.

Please Note:

 Screen must be installed 

in accordance with the requirements of 

the Local Building Codes, the Canadian 

Electrical Code 

(CEC)

, CAN/CSA C22.1, and 

the National Electric Code 

(NEC)

, NFPA 70. 

An appropriate disconnect device shall be 

provided as part of the building installation. 

Please Note:

 Do NOT wire motors in parallel.

• 

Screen ships complete 

with internal wiring. Control 

switch

(es)

 may be packed 

in cartons separate from 

screen. Wire connecting 

screen to switch

(es)

 and 

switch

(es)

 to power supply 

furnished by installer. 

"Up" Limit Adjustment

If Screen Raises Too High:

1. 

Lower screen surface approx. 1' 

(30cm)

 below desired setting  

and turn off.

2. 

Turn UP 

(II)

 limit screw clockwise  

(3 screw turns = 1/2 roller revolution).

3. 

Test by advancing screen up.

4.  

Repeat steps 1 through 3 until desired position is reached.

If Screen Needs to Raise Higher:

1.  

Lower screen surface approx. 1' 

(30cm)

 below desired setting  

and turn off.

2.  

With UP switch on, turn UP 

(II)

 limit screw counterclockwise  

(3 screw turns = 

1/2

 roller revolution)

.

3.  

Repeat steps 1 and 2 until desired position is reached.

page 8 of 12

N E 220V

Содержание Nocturne + E 220V

Страница 1: ...tions 8 Section 8 Limit Adjustments Standard Motors 8 Section 9 Wiring Diagrams 9 Section 10 Dimensions Components 10 Section 11 Assembled Dimensions 12 POWER DRILL PENCIL 2 1 TAPE MEASURE HARDWARE by...

Страница 2: ...y 12 Operation of unit should be performed only by authorized and qualified personnel who have been trained in its safe and effective operation and understand its safety features 13 The safety feature...

Страница 3: ...or selecting mounting hardware appropriate for site conditions 4 Once Case is secured to mounting surface re install Roller Assembly Quick Release Pin and Cover 5 Proceed to Section 4 Installing Cable...

Страница 4: ...el 4 Pull cable taut and mark cable under Cable Mounting Hole Wall mount option shown 1 Install Mounting Bracket using appropriate fasteners Wall mount option shown 3A Pull cable up through the Mounti...

Страница 5: ...ad barrels onto stripped end of cable above the Cable Mounting Hole on Endcap Please Note Draper recommends using two crimps per cable 8 Crimp the barrels approximately 1 8 3mm above mark PLEASE NOTE...

Страница 6: ...Fascia 1 A Replace Operator End of Roller Assembly 2 A Replace Idler Mounting Gudgeon on Idler End of Roller Assembly B Replace Quick Release Pin 3 A Replace Fascia B Replace screws on bottom of Case...

Страница 7: ...Bracket until crimped barrels are resting on Cable Mounting Hole on Endcap Deck mount option shown 2 Replace Washer and Nut on the bottom bracket and tighten until desired tension is reached Wall mou...

Страница 8: ...DOWN I and YELLOW UP II limit screws are reversed Fig 7 lI I DOWN Limit I Clockwise decreases down travel UP Limit II Counterclockwise increases up travel DOWN Limit I Clockwise decreases down travel...

Страница 9: ...ation of key operated 0n off switch if furnished IR Eye Input Low Voltage Trigger 4 28 VDC RS232 485 Inputs Outputs Receiver Button Wall Switch Green Yellow Motor Ground FUSE 3 15 AMP 250 VAC 5x20mm E...

Страница 10: ...SCREEN HEIGHT Deck Mounted Cable Guide Side Cable Wall Mount Option 3 92mm 3 92mm SCREEN HEIGHT Section 10 Dimensions Components Side Cable Ceiling Mount Option Wall Mounted Cable Guide page 10 of 12...

Страница 11: ...h 10 Flat Head Screw Mounting Bracket Square Case Curved Case Not available with Crank Operator CASE STYLES 3 92mm 3 92mm 3 92mm 3 92mm 2 68mm 1 32mm 1 44mm 1 46mm Cable Guide Deck Mount 1 28mm 1 32mm...

Страница 12: ...creen Width Overall Case Length Screen Width 2 29mm Dowel Length HEM POCKET Cable Guide Length Wall Mount Deck Mount 13mm from end of case to cable SCREEN HEIGHT 3 92mm 1 27mm from end of case to scre...

Отзывы: