220 V Micro Projector Lift by Draper, Inc.
page 2 of 4
Plenum Housing, Lift, and Closure
If you encounter any difficulties installing or servicing your 220 V a.c. Micro
Projector Lift, call your dealer or Draper, Inc. in Spiceland, Indiana, 765-987-
7999, or fax 765-987-7142.
Installing Optional Ceiling Trim Kit
The Micro Projector Lift is available with a ceiling trim kit.
This kit consists of
the lower section of the plenum housing and the optional closure panel.
Please refer to drawings below for these instructions.
➀
Install Micro Projector Lift as previously described in these instructions.
➁
Install bottom section of plenum housing in opening. This can be
accomplished by suspending with wire, or by mounting directly to the
ceiling joists (if space permits).
➂
Install projector and attach optional ceiling closure to Micro Projector Lift
(see instructions on page 3).
Upper Section
MPL
Middle Section
Lower Section
Ceiling tile
Lower section of
Plenum Housing
Installing Optional Plenum Housing
The Plenum Housing is shipped pre-assembled in its shortest position. The
height of the plenum can be adjusted by moving the screws to different
mounting holes in side panels. You can install the plenum housing in a pre-
assembled state or as separate components, which will require that the
plenum housing be completely disassembled prior to installation.
Please Note:
If the plenum is to be installed in a space where there is no access from
above the plenum, then it is recommended that the Micro projector Lift
be installed to the upper section prior to installing the plenum housing.
Please refer to drawing below for these instructions.
➀
Install top section of plenum housing using outer four holes located on top
of upper section.
➁
Attach Micro Projector Lift to upper section of plenum housing through the
inner four holes in the upper section with the
5
/
16
"–18 x
7
/
8
" hex head
screws,
5
/
16
" flat washers, and lock washers provided with plenum housing.
The lock washers should be used
above the plenum housing (one per
screw); the flat washers should be used
between the plenum housing and
the MPL (three flat washers per screw).
➂
Attach the two flat panels of the middle section across from each other
with the clinch nuts to the outside of the housing.
➃
Attach the two middle section panels with the formed ends across from
one another.
➄
Attach lower section of plenum housing.
➅
Use 25 mm foil tape (roll provided with plenum housing) to cover any
unused screw holes in plenum housing.
Overall
Height
508 mm Max.
305 mm Min.
Available
Projector/
Bracket
Height
343 mm Max.
140 mm Min.