background image

SkyLight 3 Installation Instructions

 5 

of

 6

(765) 987-7999

www.draperinc.com

Installing Relieving Roller(s)

For larger SkyLight 3 FlexShades, up to two (2)

 Relieving Rollers may be required 

to eliminate sag in the fabric. To install these 

Relieving Rollers:

 

(1)

 Locate the sliding 

Relieving Roller Anchors that were inserted in the Side  

     Channels (see Installing End Pulley Brackets: Part One - Step

 (1) 

and  

    align them with the lowest point of sag in the fabric.

 (2)

 Insert one end of the 

Roller into one of the Anchors at a slight angle  

    (see fig. 14). 

 

(3)

 Insert the other end of the 

Roller into the opposite Anchor and align parallel  

    to the 

Roller Fabric Assembly. Make sure the Draw Cables are set in the  

     channels provided at each end of the 

Roller.

 (4) 

Slide the 

Relieving Roller into position and fix into place with the provided  

   

self-tapping screws

Attaching Trim Pieces

Part One: Side Channel Trim

The 

Side Channel Trim extends along the entire length of the Side Channels. 

 

(1) 

Snap the 

Trim Piece into the Side Channel. You may need to tap them with a  

    mallet to secure them properly. Make sure that it is flush with the 

End Pulley 

  Bracket and allows plenty of room for the Tensioning Pulley and Draw  
  Cables
 to move unobstructed.

 (2)

 Secure 

Trim in place with provided self-tapping screws in the pre-drilled  

    mounting holes. These holes will line up with the 

Side Channel Mounting  

  Holes.

 (3)

 Repeat on the opposite side.

Part Two: End Pulley Bracket Fascia

 
 (1) 

Attach the 

End Pulley Bracket Trim to the skylight frame, through the  

     pre-drilled holes, using appropriate hardware (by others).

The SkyLight 3 FlexShade is now properly installed.

Electrical Connections

Shade operates on 110-120V, 60 Hz. current. Shade is shipped with internal wiring 
complete and control switch(es) fully boxed, and standardly supplied with a 6' cable 
lead. Longer lead can be substituted by removing two screws in motor end of roller, 
removing lead, plugging new lead in, and replacing screws. Wire to connect shade to 
switch(es) and switch(es) to power supply should be furnished by installer. Connec-
tions should be made in accordance with attached wiring diagram, and wiring should 
comply with national and local electrical codes.  

DO NOT wire motors in parallel without written permission from Draper.

All operating switches should be “off” before power is connected.

Please Note: 

For low voltage wiring requirements, Draper recommends consulting 

with a professional low voltage electrical contractor. It is very important that shielded 
and stranded CAT 5 cable be used to prevent any electrical interference

Limit Adjustments

1  

Connect the ILT switch to the motor via the terminal blocks, or via the modular  

  port using four conductor modular cable. When using modular cable, the cable  
  connectors MUST NOT be crimped in reverse, as with standard telephone cable.

2

  Set the slide switch to the lower position. Press and hold the DOWN button on  

  the switch to move the shade to the desired lower limit. If the shade moves in  
  the opposite direction, release the DOWN button and depress the STOP button.  
  This will reverse the operation of the UP and DOWN switches.

3

  Set the slide switch to the higher position. Move the shade to the desired upper  

  limit by pressing and holding the UP button on the wall switch.

4

  Return the slide switch to the center position to return to normal operation.

5

 To set the shade to an alternate format position, move the shade to the desired  

  position and press the STOP button. Press and hold STOP for at least three  
  seconds to record the position.

  Please Note: 

Pressing and releasing the UP button on the switch will move the  

  shade to its upper limit. Pressing and releasing the DOWN button will move the  
  shade to its lower limit. 
  While the motor is in motion, pressing STOP for less than two seconds will stop  
  the viewing surface at its present position.
  Once the motor is stopped, pressing the STOP button will move the shade to its  
  alternate format position.
  Pressing and holding the STOP button, when the motor is at rest or in motion,  
  for at least three seconds will record a new alternate format position.

POSITION

FUNCTION

DOWN

UP

CENTER

Set LOWER limit

Set UPPER limit

Normal Operation

POSITION

FUNCTION

DOWN

UP

CENTER

Set LOWER limit

Set UPPER limit

Normal Operation

S  T O 

To Motor

with

Built-In

Low Voltage

Slide

Switch

Back View 

U

p

D

o

w

n

C

o

m

m

o

n

+

5V

DC

To Motor

with

Built-In

Low Voltage

Please Note: 5V DC must be 

connected to be able to set 

limits using the wall switch.

Figure 

(14)

Содержание FlexShade SkyLight 3

Страница 1: ...ld be tested and limits set using test cord before electrician wires shade 12 Before connecting switches controls or electrical make sure power is off Wiring indicated in diagram by dashed lines must be completed by an electrician 13 Do not wire motors in parallel without written permission from Draper 14 It is the installer s responsibility to make sure appropriate fasteners are used for mounting...

Страница 2: ...th Center Tab flush with window B b w f Figure 3 Upper Section Lower Section Installing End Pulley Brackets Part One Insert Relieving Roller Anchor Before inserting the Relieving Roller Anchor confirm measurements on the card provided with the shade The length of the shade will determine whether a Relieving Roller is required and the Relieving Roller Anchor orientation Shade shorter than 122 Shade...

Страница 3: ... Motor Ring 4 Attach the Idler Mounting Bracket WARNING The following procedure REQUIRES at least two 2 installers to preform safely Part Two Motor Cable Routing see fig 8 1 Feed Motor Cable through the Cable Exit hole See Cable Exit Step 1 2 Route the Motor Cable toward the back of the Motor Mounting Bracket as shown in Fig 8 This will ensure that the Motor Cable does not interfere with the shade...

Страница 4: ...Hem Bar Slot toward the Side Channel until it stops This Draw Cable is now properly tensioned 3 Repeat on the opposite side Shade Fabric attached to Hem Bar Hem Bar in Side Channel Tensioning Pulley Draw Cables Shade Fabric attached to Hem Bar Over Tensioning Pulley Draw Cables one on each side End Bracket Pulleys End Bracket Pulleys Sticker Hem Bar in Side Channel See Attaching Cable to Hembar Be...

Страница 5: ...mply with national and local electrical codes DO NOT wire motors in parallel without written permission from Draper All operating switches should be off before power is connected Please Note For low voltage wiring requirements Draper recommends consulting with a professional low voltage electrical contractor It is very important that shielded and stranded CAT 5 cable be used to prevent any electri...

Страница 6: ...w Single Low Voltage Control Internal Shade Wiring White Neutral Black Green Ground Dashed wiring by electrician To 110 120V Line Multiple Low Voltage Controls Internal Shade Wiring White Neutral Black Green Ground Dashed wiring by electrician To 110 120V Line Wall Switch RF or IR Receiver or integrated control system Wall Switches RF or IR Receivers or integrated control systems Data Cable Data C...

Отзывы: