background image

SkyLight 3 Installation Instructions

 4 

of

 6

(765) 987-7999

www.draperinc.com

Draw Cable Routing

  The diagram below shows the proper path of the 

Draw Cables (see fig 11). 

Attaching Draw Cables to Hem Bar

Once the 

Draw Cable has been properly routed it must be attached the Hem Bar 

with the appropriate amount of tension. 

 

(1) 

To ensure proper tension, pull 

Draw Cable until the end is in line with the  

     center of the 

Orange Sticker on the Side Channel. To remove slack from the  

   

Draw Cable, rotate the Roller Assembly down (see fig. 12).

 

(2)

 Slide the

 Hem Bar to the Draw Cable and insert the Cable into the Hem Bar  

     Slot (see fig. 13) Slide the Cable along the Hem Bar Slot, toward the Side  
     Channel,
 until it stops. This Draw Cable is now properly tensioned. 

(3)

 Repeat on the opposite side.  

Shade Fabric 

(attached to Hem Bar)

Hem Bar

in Side Channel

Tensioning Pulley

Draw Cables

Shade Fabric 

(attached to Hem Bar)

Over
Tensioning 
Pulley

Draw Cables

(one on each side)

End Bracket
Pulleys

End Bracket
Pulleys

Sticker

Hem Bar

in Side Channel

See Attaching Cable 

to Hembar Below

Cable Properly Routed- Side View

Before Routing Cable - Side View

Figure 

(11)

HEM 

BAR

B

  Pull Draw Cable until the end is in 

 

line with the center of the Orange

 

Sticker on the Side Channel

 

To remove slack from the Draw Cable, 

 rotate the Roller Assembly Down.  

Draw Cable
& Sticker

Draw Cable
& Sticker

Draw Cable
& Sticker

Figure 

(12)

HEM 

BAR

C

 Insert Cable in Hem Bar Slot  

 

and slide Cable all the way 

 

to the end. 

D

 Repeat on the opposite side. 

Figure 

(13)

Содержание FlexShade SkyLight 3

Страница 1: ...ld be tested and limits set using test cord before electrician wires shade 12 Before connecting switches controls or electrical make sure power is off Wiring indicated in diagram by dashed lines must be completed by an electrician 13 Do not wire motors in parallel without written permission from Draper 14 It is the installer s responsibility to make sure appropriate fasteners are used for mounting...

Страница 2: ...th Center Tab flush with window B b w f Figure 3 Upper Section Lower Section Installing End Pulley Brackets Part One Insert Relieving Roller Anchor Before inserting the Relieving Roller Anchor confirm measurements on the card provided with the shade The length of the shade will determine whether a Relieving Roller is required and the Relieving Roller Anchor orientation Shade shorter than 122 Shade...

Страница 3: ... Motor Ring 4 Attach the Idler Mounting Bracket WARNING The following procedure REQUIRES at least two 2 installers to preform safely Part Two Motor Cable Routing see fig 8 1 Feed Motor Cable through the Cable Exit hole See Cable Exit Step 1 2 Route the Motor Cable toward the back of the Motor Mounting Bracket as shown in Fig 8 This will ensure that the Motor Cable does not interfere with the shade...

Страница 4: ...Hem Bar Slot toward the Side Channel until it stops This Draw Cable is now properly tensioned 3 Repeat on the opposite side Shade Fabric attached to Hem Bar Hem Bar in Side Channel Tensioning Pulley Draw Cables Shade Fabric attached to Hem Bar Over Tensioning Pulley Draw Cables one on each side End Bracket Pulleys End Bracket Pulleys Sticker Hem Bar in Side Channel See Attaching Cable to Hembar Be...

Страница 5: ...mply with national and local electrical codes DO NOT wire motors in parallel without written permission from Draper All operating switches should be off before power is connected Please Note For low voltage wiring requirements Draper recommends consulting with a professional low voltage electrical contractor It is very important that shielded and stranded CAT 5 cable be used to prevent any electri...

Страница 6: ...w Single Low Voltage Control Internal Shade Wiring White Neutral Black Green Ground Dashed wiring by electrician To 110 120V Line Multiple Low Voltage Controls Internal Shade Wiring White Neutral Black Green Ground Dashed wiring by electrician To 110 120V Line Wall Switch RF or IR Receiver or integrated control system Wall Switches RF or IR Receivers or integrated control systems Data Cable Data C...

Отзывы: