background image

Installation Instructions 

SkyLight 3 FlexShade

  

 CAUTION 

(1)

 

Inspect all boxes to make sure you have received the proper shades and parts. 

   Controls may be shipped separately, or in same carton as shades.

(2)

 Open cartons lengthwise.

(3)

 Do not over-tighten Draw Cables. Over-tightening could cause damage to the  

  window frame.

(4)

 Inside Measurement (IM) = Outside Measurement (OM) minus 

1

/

8

".

(5)

 During installation and adjustment, the hem bar must not be allowed to contact  

  the mounting brackets. Doing so could damage the unit. Insure that pinch points  

  between the mounting brackets and hem bar are kept clear during operation.  

  Set the motor limits so that the shade stops about ½" away from the mounting  

  brackets at both ends of shade travel.

(6)

 Unit is not designed for fabric to lay perfectly flat. Some sag is to be expected.

(7)

 Periodic Draw Cable tensioning may be required.

(8)

 Unit should not be installed on an Incline-UP orientation (motor at bottom).

(9)

 If you are planning to place a decorative fascia below the unit to hide the edges  

  make certain that no part of the fabric panel or draw cable touch the fascia.  

  If any part of the shade comes into contact with any adjacent fascia the  

  additional friction may prevent the unit from operating reliably.

(10)

 Safe installation of this unit requires two or more people.

(11)

 All motors should be tested and limits set using test cord before electrician  

  wires shade.

(12)

 Before connecting switches, controls, or electrical, make sure power is off.  

  Wiring indicated in diagram by dashed lines must be completed by an electrician.

(13)

 Do not wire motors in parallel without written permission from Draper.

(14)

 It is the installer’s responsibility to make sure appropriate fasteners are used for  

  mounting the unit.

(15)

 Please read the following installation guidelines thoroughly and follow them  

  carefully. Failure to do so may cause product to fall or otherwise fail, and  

  invalidates warranty.

Please Note: Custom products/installations may not be reflected by this 

document. Call Draper, Inc. if you have questions about your installation.

Tools Required:

Tape Measure 

   Hex Wrench 

   Power Drill 

   Wire Strippers 

Crosshead Screwdriver       Flathead Screwdriver 

  Rubber Mallet 

   Fastening Hardware 

       

 

 

(By 

others) 

Copyright © 2016 Draper Inc. 

Form SkyLight3_Inst16         Printed in U.S.A.

SkyLight 3 

Components:

(1)

 Motor Mounting Brackets (Upper / Lower Sections)

(2) 

Side Channels (2)

(3)

 Trim for Side Channels (2)

(4)

 Trim for Motor End

(5)

 Trim for Pulley Bracket End 

(6)

 Roller Fabric Assembly:

   (Motor /// Fabric /// Hem Bar /// Tensioning Pulleys /// Draw Cables) 

(7)

 Relieving Roller (if required)

(8)

 Relieving Roller Anchors (if required)

(9)

 End Pulley Brackets (2)

Inspect all boxes to make sure you have received the proper shades and parts. 

Controls may be shipped separately, or in same carton as shades.

SK

YLIGH

T WIN

DOW F

RA

ME

S

KY

L

IGHT WI

NDOW F

RA

M

E

ROOM

FLOOR

B

C

D

E

F

G

H

I

J

Figure 

(1)

Содержание FlexShade SkyLight 3

Страница 1: ...ld be tested and limits set using test cord before electrician wires shade 12 Before connecting switches controls or electrical make sure power is off Wiring indicated in diagram by dashed lines must be completed by an electrician 13 Do not wire motors in parallel without written permission from Draper 14 It is the installer s responsibility to make sure appropriate fasteners are used for mounting...

Страница 2: ...th Center Tab flush with window B b w f Figure 3 Upper Section Lower Section Installing End Pulley Brackets Part One Insert Relieving Roller Anchor Before inserting the Relieving Roller Anchor confirm measurements on the card provided with the shade The length of the shade will determine whether a Relieving Roller is required and the Relieving Roller Anchor orientation Shade shorter than 122 Shade...

Страница 3: ... Motor Ring 4 Attach the Idler Mounting Bracket WARNING The following procedure REQUIRES at least two 2 installers to preform safely Part Two Motor Cable Routing see fig 8 1 Feed Motor Cable through the Cable Exit hole See Cable Exit Step 1 2 Route the Motor Cable toward the back of the Motor Mounting Bracket as shown in Fig 8 This will ensure that the Motor Cable does not interfere with the shade...

Страница 4: ...Hem Bar Slot toward the Side Channel until it stops This Draw Cable is now properly tensioned 3 Repeat on the opposite side Shade Fabric attached to Hem Bar Hem Bar in Side Channel Tensioning Pulley Draw Cables Shade Fabric attached to Hem Bar Over Tensioning Pulley Draw Cables one on each side End Bracket Pulleys End Bracket Pulleys Sticker Hem Bar in Side Channel See Attaching Cable to Hembar Be...

Страница 5: ...mply with national and local electrical codes DO NOT wire motors in parallel without written permission from Draper All operating switches should be off before power is connected Please Note For low voltage wiring requirements Draper recommends consulting with a professional low voltage electrical contractor It is very important that shielded and stranded CAT 5 cable be used to prevent any electri...

Страница 6: ...w Single Low Voltage Control Internal Shade Wiring White Neutral Black Green Ground Dashed wiring by electrician To 110 120V Line Multiple Low Voltage Controls Internal Shade Wiring White Neutral Black Green Ground Dashed wiring by electrician To 110 120V Line Wall Switch RF or IR Receiver or integrated control system Wall Switches RF or IR Receivers or integrated control systems Data Cable Data C...