background image

 Caution: 

1. 

Inspect all boxes to make sure you have 

received the proper shades and parts. 

Controls may be shipped separately, or in 

same carton as shades. 

2. 

Open cartons lengthwise, taking care not 

to cut into cardboard shipping container.

3. 

Before mounting shades, verify 

measurements on label provided with shade, 

and ensure unit is installed at correct width.

4. 

All endcaps, fascia, pocket headbox, and 

other hardware must be installed level. 

Shades must be level and square.

6.  Read the following installation guidelines 

thoroughly and follow them carefully. 

Failure to do so may cause product to fall or 

otherwise fail, and invalidates warranty.

7.  Installer is responsible for selecting mounting 

hardware appropriate for site conditions.

PLEASE READ -

 Field Adjustments

Each Draper Solar Control Shade is tested to 
ensure proper operation. Even with this testing, 
some field adjustments may be needed for 
telescoping. 

If the shade is telescoping, place a piece of 
shimming fabric into the fabric roll when the shade 
is deployed on the side that the fabric will be drawn 
toward. For example: if the fabric is tracking to the 
left, place the shimming fabric on the right side.

PLEASE READ -

 Cleaning and Maintenance

Window covering products manufactured by Draper, when properly installed, should require no 

operational maintenance or lubrication.

Most standard Draper fabrics may be cleaned at the window by vacuuming with a soft brush 

attachment. They also may be cleaned by using a sponge or soft cloth and mild solution of warm 

soapy water. A mild dishwashing liquid is recommended. A clean dry cloth is recommended for the 

metal finish. 

Please Note:

 Exceptions are GreenScreen Evolve

®

, GreenScreen Revive

®

, and Phifer

®

 SW7000 

fabrics, which must be cleaned with a dry art sponge. 

(GreenScreen Revive

®

 and GreenScreen Evolve

®

 are registered trademarks of Mermet

®

 USA. SheerWeave

®

 is 

a registered trademark of Phifer

®

 Incorporated.)

page 2 of 10

Exterior Motorized FlexShade

®

 XL

 WARNING   

Improper installation and use of the Exterior Motorized FlexShade

®

 XL can result in serious injury or death. Primarily, injuries can occur if the 

unit falls due to imprecise installation, mishandling of the unit during installation, or installation on an insufficient wall or ceiling structure. 

Please use extreme care. 

1. 

Please read the following installation guidelines thoroughly and follow them 

carefully. Failure to do so may cause product to fall or otherwise fail, and 

could result in serious injury. 

2. 

Installation and calibration of the unit should only be performed by an 

authorized, qualified, and experienced professional. In particular, electrical 

work and wiring [indicated in diagram by dashed lines] must be completed 

only by a qualified professional electrician who has read this manual 

completely and is familiar with the construction and operation of this 

equipment and the hazards involved. 

3. 

Do not affix the unit to wall or ceilings that have inadequate strength to 

permanently hold the unit during use. It is the owner’s and installer’s 

responsibility to confirm the wall or ceiling to which the unit attaches is 

sufficient to permanently hold the weight and stress loads of the unit at all 

times. Draper

®

, Inc., is not responsible for improper installation, application, 

testing, or workmanship related to the product at place of installation. 

4. 

It is the installer’s responsibility to make sure appropriate fasteners are used 

for mounting. 

5. 

All brackets, fascia, headboxes, pockets, wall clips, and other hardware 

must be installed level. Unit must be level and square. 

6. 

Never leave the area while operating the unit during installation, 

maintenance, or normal operation, unless it is secure and safe. 

7. 

Before testing or operation, carefully inspect the entire area and path of the 

shade and areas underneath the shade to be sure no persons or objects are 

in the area. 

8. 

Turn off power and any nearby equipment or cables carrying electricity 

before connecting switches, wires, controls, or electrical components. 

9. 

Make sure the limit switches are pointed down or accessible when placing 

the motor in brackets/endcaps.

10. 

All motors should be tested and limits set using test cord before shades are 

wired. 

11. 

Do not wire motors in parallel without written permission from Draper, Inc. 

12. 

During testing or operation, carefully watch the surrounding area for any 

potential safety concerns including nearby persons or objects. 

13. 

After installation, the entire system, including all sensors, should be carefully 

tested to ensure safe and normal operation. Extreme care should be taken 

during testing to remain clear of moving parts to avoid possible injury. 

14. 

Operation of unit should be performed only by authorized and qualified 

personnel, who have been trained in the safe and effective operation of the 

unit and understand its safety features. 

15. 

The safety features of the unit, including sensors, should never be disabled, 

bypassed, or overridden. The system should not be operated until all safety 

features, including the sensors, are properly and completely installed, 

calibrated, and tested. 

16. 

Unit may need to comply with local, state, or district rules and regulations, 

in particular when installed in schools. All applicable rules and regulations 

should be reviewed before installation and use. 

17. 

Failure to precisely follow installation guidelines invalidates all warranties. 

18. 

Custom products/installations may not be reflected in this manual. Call 

Draper, Inc., if you have questions about the installation of custom products 

or any questions about your installation. 

Before Beginning Installation
1. 

Look for any job site conditions that could interfere with installation or 

operation of the system.

2. 

Read carefully and be sure to understand all installation instructions and 

all related operations manuals. These instructions are intended to serve 

as a guide for the installer and owner. They should be followed closely and 

combined with the expertise of experienced qualified installers. Draper, 

Inc., is not responsible for improper installation, application, testing, or 

workmanship related to the product at place of installation. Please retain all 

instructions for future use.

3. 

Open cartons lengthwise.

4. 

Locate and lay out all pieces.

5. 

Inspect all boxes to make sure you have received the proper shade and 

parts. Controls may be shipped separately, or in same carton as shade.

6. 

If you have any difficulties with installing, servicing, or operating your shade, 

call your dealer or Draper, Inc., 765-987-7999.

Important Safety Information

Important Safety Information

PLEASE READ -

 Important Installation Information

PLEASE READ -

 Safety Information

Содержание Exterior Motorized FlexShade XL

Страница 1: ... Mount 10 POWER DRILL PENCIL 2 1 TAPE MEASURE HARDWARE by others LEVEL PLIERS CRIMPING TOOL WIRE STRIPPERS CAUTION Read and understand all warnings before beginning installation HEADBOX SHADE FABRIC MOUNTING BRACKETS Ceiling Mount shown HEM BAR END CAP SIDE CABLE SIDE CABLE CABLE GUIDE Wall Mount shown CABLE GUIDE Deck Mount shown LASER LEVEL Draper Inc 411 S Pearl St Spiceland IN 47385 draperinc ...

Страница 2: ...le for improper installation application testing or workmanship related to the product at place of installation 4 It is the installer s responsibility to make sure appropriate fasteners are used for mounting 5 All brackets fascia headboxes pockets wall clips and other hardware must be installed level Unit must be level and square 6 Never leave the area while operating the unit during installation ...

Страница 3: ...p mounting holes Fig 3 A 1 Attach mounting brackets to ceiling using 10 flat head screws installed flush with bracket USE ALL FOUR 4 mounting holes Fig 3 B 2 Attach Headbox to brackets and tighten Set Screws Fig 3 B 3 Install Cable Guides Section 3 Please Note Hem Bar does not retract into the Headbox and must be accounted for if mounting over a swinging window or door 3 Mounting brackets MUST be ...

Страница 4: ...le at the bottom of the endcap flange 5 Undo the nut and pull the cable down until the mark aligns with the bottom of the endcap deck mount option shown 7 Crimp the barrels approximately 1 8 3mm above pencil mark 7 20cm 8 Cut cable approximately 1 25mm above crimped barrels 9 Pull cable down until crimped barrels are resting on the flange CAUTION Headbox shown removed from image for demonstration ...

Страница 5: ...otor jogs then release 2 Check motor direction To reverse motor direction hold MY STOP button for 5 seconds until motor jogs Check direction again 3 Move motor to upper limit position Hold MY STOP and DOWN buttons until motor moves down then release Use UP and DOWN buttons to move shade to correct lower limit and press MY STOP 4 While motor is at lower limit hold UP and MY STOP buttons until motor...

Страница 6: ... Bottom View Side View GLASS SIDE ROOM SIDE Front Back Bottom View Side View Screws Front Back Bottom View Side View GLASS SIDE ROOM SIDE Screws Front Back Bottom View Side View GLASS SIDE ROOM SIDE PUSH BUTTON LIMITS Standard right hand motor configuration shown SCREW TYPE LIMITS Standard right hand motor configuration shown Section 6 Complete Electrical Connection Operates on 110 120V 60 Hz curr...

Страница 7: ...and out the fabric opening under the motor Please Note Right hand motor is shown 19mm 17mm Cable Exit SIDE TOP BACK 13mm ENDCAP F R O N T F R O N T 9 5mm 13mm 22mm 1 25mm Cable Exit TOP TOP BACK 13mm ENDCAP F R O N T F R O N T 9 5mm 13mm 1 30mm Cable Exit BACK TOP BACK 13mm ENDCAP F R O N T F R O N T F R O N T Figure 5 A Figure 5 B Figure 5 C page 7 of 10 Exterior Motorized FlexShade XL ...

Страница 8: ...4mm 1 46mm Angled Headbox Deck Mounting Bracket Cable Guide Deck Mount 5 127mm 5 127mm 5 127mm 5 127mm CURVED HEADBOX ANGLED HEADBOX 5 127mm 5 127mm 5 127mm 5 127mm CURVED HEADBOX ANGLED HEADBOX 1 44mm 1 25mm 1 38mm Ø 6 4mm 1 28mm 1 32mm 2 57mm 1 29mm 1 25mm Curved Headbox Wall Mounting Bracket Cable Guide Wall Mount page 8 of 10 Exterior Motorized FlexShade XL ...

Страница 9: ... Length 2 57mm 1 30mm Fabric Width Headbox Height A A B Hem Bar 7 184mm Headbox Height B 5 127mm Deck Mounted Cable Guide option configured for Inside Mount For Outside Mount installation Cable Guide may be turned 90 Wall Mounted Cable Guide option page 9 of 10 Exterior Motorized FlexShade XL ...

Страница 10: ...Section 10 Dimensions Deck Mount Section 11 Dimensions Wall Mount 5 127mm 5 127mm SHADE HEIGHT 8mm 7 184mm 5 127mm 5 127mm SHADE HEIGHT 7 184mm page 10 of 10 Exterior Motorized FlexShade XL ...

Отзывы: