Case Dimensions
*These wiring diagrams are for Access XL screens with motor on audi-
ence left (standard), and fabric unrolling from the back of the roller
(standard).
www.draperinc.com
(765) 987-7999
Wiring Diagrams—220V Motor
Please Note: Do not wire motors in parallel.
L
Series V-L=varies
Series E-L=160mm
229mm
216mm
241mm
254
mm
Evenly Spaced
Evenly Spaced
Evenly Spaced
Centered over roller bracket (+/-102mm)
25.4
mm
265
mm
Series E Case Length = Fabric width + 321mm
Series V Case Length = Varies
197mm
Ceiling Mounting Bracket Locations and Configurations
Typical Installation: Two outermost ceiling
mounting brackets (on the ends) must be
centered over the interior roller brackets (+/-
102mm). Two intermediate brackets should
be spaced evenly from the outermost ceiling
mounting brackets.
Alternate Installation: Two outermost ceiling mounting
brackets (on the ends) are centered over the inte-
rior roller brackets (+/-102mm), parallel to the case.
The two intermediate brackets should be placed in
the typical perpendicular configuration, and spaced
evenly from the outermost ceiling mounting brackets.
Neutral
L1
220v,
50 Hz.
Dashed wiring
by installer
Control
switch
Single Station Control
CE Approved
Junction box at
left end of screen
Internal Screen Wiring
Blue-220v (Common)
Brown-220v (Down)
Black-220v (Up)
Dashed wiring
by installer
Neutral
Hot
Multiple Station Control
Not CE Approved
Cap off with wire
nut & tape
Red
Red
Red
Blue
Blue
Blue
Black
Black
220v, 50 Hz.
Black
Junction box at
left end of screen
Internal Screen Wiring
Blue-220v (Common)
Brown-220v (Down)
Black-220v (Up)
Green/Yellow (Motor Ground)
Green/Yellow (Motor Ground)
Wiring Diagrams—220V Motor
with Built-in Low Voltage Controller
Single Low Voltage Control
Dashed wiring
by electrician
To 220V Line
Multiple Low Voltage Controls
Dashed wiring
by electrician
To 220V Line
Wall Switch,
RF or IR
Receiver,
or integrated
control system
Wall Switches,
RF or IR
Receivers,
or integrated
control systems
Data Cable
Data
Cables