Case Dimensions

*These wiring diagrams are for Access XL screens with motor on audi-

ence left (standard), and fabric unrolling from the back of the roller 

(standard).

www.draperinc.com

(765) 987-7999

Wiring Diagrams—220V Motor

Please Note: Do not wire motors in parallel.

L

Series V-L=varies

Series E-L=160mm

229mm

216mm

241mm

254

mm

Evenly Spaced

Evenly Spaced

Evenly Spaced

Centered over roller bracket (+/-102mm)

25.4

mm

265

mm

Series E Case Length = Fabric width + 321mm

Series V Case Length = Varies

197mm

Ceiling Mounting Bracket Locations and Configurations

Typical Installation: Two outermost ceiling 

mounting brackets (on the ends) must be 

centered over the interior roller brackets (+/- 

102mm). Two intermediate brackets should 

be spaced evenly from the outermost ceiling 

mounting brackets.

Alternate Installation: Two outermost ceiling mounting 

brackets (on the ends) are centered over the inte-

rior roller brackets (+/-102mm), parallel to the case. 

The two intermediate brackets should be placed in 

the typical perpendicular configuration, and spaced 

evenly from the outermost ceiling mounting brackets.

Neutral

L1

220v, 
50 Hz.

Dashed wiring 
by installer

Control
switch

Single Station Control

CE Approved

Junction box at 

left end of screen

Internal Screen Wiring

Blue-220v (Common)

Brown-220v (Down)

Black-220v (Up)

Dashed wiring 
by installer

Neutral

Hot

Multiple Station Control

Not CE Approved

Cap off with wire
nut & tape

Red

Red

Red

Blue

Blue

Blue

Black

Black

220v, 50 Hz.

Black

Junction box at 

left end of screen

Internal Screen Wiring

Blue-220v (Common)

Brown-220v (Down)

Black-220v (Up)

Green/Yellow (Motor Ground)

Green/Yellow (Motor Ground)

Wiring Diagrams—220V Motor

with Built-in Low Voltage Controller

Single Low Voltage Control 

Dashed wiring  
by electrician 

To 220V Line

Multiple Low Voltage Controls 

Dashed wiring  
by electrician 

To 220V Line

Wall Switch, 

RF or IR 

Receiver, 

or integrated 

control system 

Wall Switches, 

RF or IR 

Receivers, 

or integrated 

control systems 

Data Cable 

Data 
Cables 

 