Draper Access XL Скачать руководство пользователя страница 1

Installation/Operating Instructions

Access XL 220V Electric Projection Screen by Draper

Copyright © 2014 Draper Inc.  Form AccessXL220_Inst15 

Printed in U.S.A

Hanging Screen 

When locating viewing surface and checking clearance for screen operation, 

remember surface is centered in the length of the case. Regardless of mounting 

method used, the following points apply:

1

  Engage each ceiling mounting bracket with top of housing as shown below and  

  tighten nuts. The outer two brackets should be centered above the location of  

  the interior roller brackets (+/-102mm). The remaining two brackets should be  

  equally spaced between the outermost brackets.

2

  Screen should be lifted into position 

only by the outermost ceiling mounting  

  brackets (those on ends). Keep case level by lifting each end simul- 

  taneously to prevent surface damage. Never attempt to lift screen along  

  its length.

3

 The 

entire weight

 of the unit 

MUST BE

 supported by the outermost mounting  

  brackets to provide a secure installation (those on ends). 

Do not use  

  intermediate brackets to lift or support the weight of the screen.

4

  Screen should be positively and securely supported so that vibration or even  

  abusive pulling on viewing surface will not weaken installation.

Electrical Connections

Screen operates on 220V, 50 Hz., 1ph with max 2.1 amp current draw.

Junction box is located just above the bottom access panel at left end of screen 

(standard, right end may be specified). Remove the bottom access panel for 

access to the junction box cover. (See Bottom Access Panel Removal instructions 

below.) Remove four (4) hex head screws that secure the cover to the junction box 

to expose the black, brown and blue pigtail leads and the green/yellow ground wire 

per wiring diagram on page 4.

If optional low voltage control or video interface control is specified and factory 

installed, please refer to wiring diagrams on page 5.

Screen is shipped with internal wiring complete and control switch (es) fully boxed. 

Wire to connect screen to switch (es) and switch (es) to power supply should be 

furnished by installer. 

Connections must be made in accordance with attached 

wiring diagram, and wiring must comply with national and local electrical 

codes.

All operating switches should be “off” before power is connected.

Bottom Access Panel Installation/Removal

  Removal and replacement of the bottom closure panel requires two people 

positioned about 152cm from each end of the panel.

1

  Before removing bottom closure, you must first remove screws at each  

 

end of case and slide the closure clips inward, away from the outside of  

 

the case (see Fig. 3).

 

 

 

 

If you encounter any difficulties installing or servicing your Access XL screen, call your 

dealer or Draper, Inc., in Spiceland, Indiana, 765/987-7999 or fax 765/987-7142.

Suitable for use in environmental air space in accordance with Section 

300-22(c) of the National Electrical Code, and Sections 2-128, 12-010(3) and 

12-100 of the Canadian Electrical Code, Part 1, CSA C22.1.

Typical Installation

Alternate 

Installation

(additional set of 

brackets required 

but not included). 

Two intermediate 

brackets must be 

spaced evenly 

from ends.

Slots along top of case 

  permit brackets to be 

      set at an angle

Case dimensions 

on page 3.

Caution

1

  Read instructions through completely before proceeding.

2

  Follow instructions carefully. Installation contrary to instructions  

invalidates warranty.

3

  Pick up screen case from 

ends only

. Picking case up at other points 

will 

damage case 

and 

may damage fabric

.

4

  To insure a safe installation, the 

entire weight

 of the unit MUST BE  

supported by outermost ceiling mounting brackets (those on ends). 

Don't 

use intermediate brackets to lift or support the weight of the screen.

5

 

To eliminate the possibility of the case warping, outermost ceiling 

mounting brackets (those on ends) must be located centered above 

the interior roller mounting brackets (+/-102mm).

6

  Entire bottom of screen case should be unobstructed to permit access to 

bottom panel for making electrical connections or servicing.

7

  Screen should be installed level (using a carpenter’s level).

8

  Operating switch(es) packed separately in screen carton. Do not discard 

with packing material.

9

  An appropriate disconnect device shall be provided as part of the building 

installation.

10 

Screen operates on 220V, 50 Hz., 1ph. with max 2.1 amp draw.

NOTE

: Screen has been thoroughly inspected and tested at factory and found 

to be operating properly prior to shipment.

5

  Installer must insure that fasteners used are of adequate strength and  

  suitable for the mounting surface chosen. 

Installer must also insure that  

  ceiling structure is of adequate strength. 

Supporting hardware (chains,  

  cables, 9.5mm rods, etc.) must be essentially vertical.

6

  Entire bottom of case must be readily accessible after installation is complete.

7

  Front, back and top of case must be straight—not forced to warp or bow  

  (see note 5 in caution box).

8

  Do not use case to support adjacent sections of ceiling.

9

  If case is painted on location, removal of roller/fabric assembly is recommended  

  prior to painting. If not removed, slot on bottom of case should be shielded to  

  protect viewing surface from paint splatters or overspray.

10

  Do not seal unit in ceiling until electrical connections have been made and  

  screen has been operated successfully.

Dowel

Shipping

Bracket

Shipping Brackets

  If provided, remove shipping brackets by following Figure 2.

Figure 2

Series V

Closure

Case

Figure 3

Continued on next page

Front of case 

removed for 

clarity

 

Motor Type 

Duty  Cycle                                           

  506S2PA, 510S2PA, 515S2PA, 

1 minute on, 3 minutes off

 

506S2 ILT2, 515S2 ILT2

  525A2PA, 535A2PA, 535A2 ILT2 

1 minute on, 10 minutes off

 NOTE: Excessive continuous operation may cause the motor to over  

 heat. If this happens the motor will shut off until it cools to a normal  

 operating temperature.

These Installation/Operating Instructions are available in the official language of 

the country where you purchase the product. Please contact your distributor to 

request a copy.

Vous pourriez demander les instructions d’installation et d’opération traduises 

dans la langue officielle du pays ou vous achetez le produit. Veuillez demander à 

votre distributeur.

Die Gebrauchsanweisung für Installation und Konstruktion sind in der offiziellen 

Sprache des Landes, indem Sie das Produkt gekauft haben, vorhanden. Fragen 

Sie die jeweilige Verkaufs-Abteilung.

US Patent Nos. 6,137,629; 6,421,175; 6,532,109; 6,816,308; 7,559,707

7

/

8

" electrical cutout

These instructions are meant as a guide only. They do not imply any responsibility 

on the part of the manufacturer for improper installation or faulty workmanship at 

the jobsite.

Отзывы: