Draper Access FIT E Скачать руководство пользователя страница 3

CENTER of CASE

CENTER 

of CASE

 

Engagement Bracket

With Ball Detent:

will snap into Access

Panel Support Bracket.

Access Panel

Support Bracket

1

2

 

 

 

 

 

Attaching Brackets:

Insert pin in top

slot and push up.
Rotate bracket

clockwise to lock

bracket in place.

Remove Screws

from both ends 

of Screen Housing.

Access 

Panel Door:

Pivot on Hinges. 

OPEN 

ACCESS 

PA

NEL

CLOSED 

ACCESS P

ANEL

SCREEN

HOUSING

Section 3 -

 Bottom Access FIT Panel Installation/Removal

Figure 3

Access case as seen from below

Bottom Access FIT panel secures to the screen housing 

with two screws 

(one on each end)

, and held in the closed 

position by engagement brackets with ball detents that 

snap into case support brackets 

(Fig. 3)

.

 CAUTION:

 For larger sizes, the following requires two people to perform safely.

Bottom flange of 

Access housing

Bottom Access Panel Door

CAUTION: Beware of pinch points at ends of closure

Please Note:

 When locating viewing surface and checking clearance for screen operation, ensure that surface is centered in the case.

1. 

Engage each case mounting bracket 

(attached to case)

 with top of housing 

(Fig. 2)

 and tighten set screws.

Section 2 -

 Hanging Screen

2. 

Screen should be sufficiently supported to withstand 

vibration.

Please Note:

 A hoisting bracket is included on each end of the 

case to aid in overhead installation.

3. 

Ensure that fasteners are of adequate strength and suitable 

for the mounting surface chosen. Supporting hardware 

such as chains, cables, two 

3/8

(9.5 mm)

 rods, etc., must be 

precisely vertical.

4. 

Entire bottom of case must be readily accessible after 

installation is complete.

5. 

Front, back, and top of case must be straight—not forced  

to warp or bow.

 CAUTION:

 Screen case and flange are not designed to 

serve as ceiling support.

6. 

Do not seal unit in ceiling until electrical connections have 

been made and screen operates successfully.

Please Note:

 If case is painted on location, removal of roller/

fabric assembly is recommended prior to painting. If not 

removed, slot on bottom of case should be shielded to  

protect viewing surface from paint splatters/overspray.

HOISTING 

BRACKET

CASE 

MOUNTING 

BRACKET

CASE 

MOUNTING 

BRACKETS

7⁄8

(22mm) 

ELECTRICAL 

KNOCKOUT

ALTERNATE

INSTALLATION

Additional set of brackets 

required, but 

NOT 

included.

TYPICAL 

INSTALLATION

With typical installation, brackets 

may be angled to meet installation requirements.

HOISTING 

BRACKET

CASE 

MOUNTING 

BRACKET

CASE 

MOUNTING 

BRACKETS

7⁄8

(22mm) 

ELECTRICAL 

KNOCKOUT

ALTERNATE

INSTALLATION

Additional set of brackets 

required, but 

NOT 

included.

TYPICAL 

INSTALLATION

With typical installation, brackets 

may be angled to meet installation requirements.

Figure 2

Installation of Case

Figure 4

Removing Access Panel

1. 

Press up on Access FIT panel and pull toward the front of the 

screen housing to disengage hinges and remove Access FIT panel.

2. 

To Remove/Install Support Brackets:

page 3 of 8

Access FIT E and V

Содержание Access FIT E

Страница 1: ...al Cutout Tab Tensioning V Dowel E Dowel Mounting Bracket Mounting Bracket Hoisting Bracket Leveling Brackets Hoisting Bracket E Free Hanging Viewing Surface V Flexible Vinyl Viewing Surface Trim Flan...

Страница 2: ...carefully tested to ensure safe and normal operation Extreme care should be taken during testing to remain clear of moving parts to avoid possible injury 12 Operation of unit should be performed only...

Страница 3: ...steners are of adequate strength and suitable for the mounting surface chosen Supporting hardware such as chains cables two 3 8 9 5 mm rods etc must be precisely vertical 4 Entire bottom of case must...

Страница 4: ...knobs are visible from bottom of screen housing Please Note If snap ring is provided make sure it engages with motor If retaining clip is provided instead install to lock motor end in place 7 Support...

Страница 5: ...when fully up or fully down Installer should incorporate an all pole disconnect in fixed wiring available with RF or IR remote KEY OPERATED SWITCHING Two key operated switches optionally available wi...

Страница 6: ...crew turns 1 2 roller revolution 3 Test by lowering screen Repeat steps 1 2 until desired position is reached To Increase Screen Drop 1 Lower screen to down limit 2 With down switch on turn DOWN I lim...

Страница 7: ...of Screen Case Center of Case 3 76mm 13mm 4 124mm 6 164mm 5 130mm 11mm 2 51mm 7 197mm 22mm 16mm 16mm 5 144mm 11mm 1 35mm 7 197mm 6 165mm 3 87mm For minimum length of ceiling cutout subtract 11 4 32mm...

Страница 8: ...N Black COM White UP Red Wall Switch Electrically Straight Data Cable to more LVC IV modules FUSE 3 15 AMP 250 VAC 5x20mm To 110 120 VAC Line Red to screen directional Brown to screen directional Yell...

Отзывы: