10.1 ANVIL – FIG. 7
– Ensure the anvil ring
is correctly maintained
and if damaged or missing is replaced
immediately before work commences.
– Ensure the socket correctly locates on the anvil
firmly engaging on the anvil ring
.
Note:
It is natural for the socket to resist removal.
10.2 EVERY-DAY MAINTENANCE
CHECKS
Before connection to the air supply:
– Drain the compressor reservoir of condensate.
– Drain the air lines of condensate.
– Drain the combined separator filter, regulator,
water trap.
– Fill up the combined separator filter, regulator,
lubricant reservoir.
– Check the line pressure is correct for the tool.
10.3 AFTER USE MAINTENANCE CHECKS
– Repeat the above procedures.
– Lubricate the tool with approximately 1.5ml of oil directly down the air inlet.
10. MAINTENANCE
- 14 -
FIG.7
Warning!
●
Disconnect from the air supply before carrying out any adjustments, servicing or
maintenance.
●
Never use any sockets or accessories that are not hardened for impact use.