Draper 36327 Скачать руководство пользователя страница 7

5.3 CONNECTION TO THE POWER SUPPLY

Make sure the power supply information on the machine’s rating plate are compatible with 
the power supply you intend to connect it to. 
This water pump comes supplied with a UK standard 3 pin plug fitted.  It is designed for 
connection to a domestic power supply rated at 230V AC.

Apart from replacing the fuse in the plug, no other electrical work is recommended on this 
water pump.

5.2 SPECIFIC SAFETY INSTRUCTIONS FOR PUMP USE

Have this tool repaired by a qualified person.

 This tool is designed to confirm to the relevant 

international and local standards and as such should be maintained and repaired by someone 
qualified; using only original parts supplied by the manufacturer: This will ensure the tool 
remains safe to use.

1.  Before connecting to the power supply:
 

i. A residual current circuit breaker (RCD) must be used for all applications.

 

ii. The electrical supply should be the same as stated on the rating plate.

2.  Surface mounted pumps should always be transported and stored horizontally on the base 

plate.

3.  Always ensure that hands are dry when connecting and disconnecting the power supply.
4.  Never operate the pump dry.
5.  The area being pumped should be kept clear, nobody should enter area while pump is 

operating.

THE FOLLOWING ADDITIONAL INSTRUCTIONS MUST BE FOLLOWED AT ALL TIMES. FAILURE 
TO DO SO COULD INVALIDATE THE GUARANTEE OF THIS SUBMERSIBLE WATER PUMP.
1.  The float switch must be clamped in position using cable clamp recess (see page 9, fig.10).
2.  Clean water pumps are not suitable for use in dirty water.
3.  These water pumps are designed for pumping water only.
 

The addition of any chemicals, chlorine or additives to the water could damage the pump, 
this would be considered misuse and would not be covered under warranty.

4.  When using clean water pumps in a pond or where there is gravel, mud, leaves, etc.
 

NOTE: The pump, should be suspended using a rope or chain or stood on a brick to 
prevent any gravel, etc., being sucked into the pump.

5.  If the pump fails to operate, disconnect from mains supply. Remove output elbow and 

turn the impeller using a screwdriver or finger. Check for obstruction in the impeller, i.e. 
stones/gravel, etc.

6.  The float switch fitted to this pump is not suitable for continuous use as an on/off switch.
 

IMPORTANT: ANY PUMP RETURNED TO DRAPER TOOLS UNDER WARRANTY MUST BE 
CLEAN. IF A PUMP IS RECEIVED THAT IS NOT, OR HAS NOT BEEN CLEANED, IT WILL BE 
RETURNED TO YOU AT YOUR COST.

7

5.  HEALTH & SAFETY INFORMATION

Содержание 36327

Страница 1: ...ontains all the necessary information to ensure its correct and safe use By following all the general safety instructions contained in this manual it will ensure both product and operator safety together with longer life of the product itself AlI photographs and drawings in this manual are supplied by Draper Tools to help illustrate the operation of the product Whilst every effort has been made to...

Страница 2: ...44 0 23 8026 0784 EASTLEIGH HAMPSHIRE SO53 1YF UK 1 3 UNDERSTANDING THIS MANUALS SAFETY CONTENT WARNING Information that draws attention to the risk of injury or death CAUTION Information that draws attention to the risk of damage to the product or surroundings NOTE Important information 1 4 COPYRIGHT NOTICE Copyright Draper Tools Limited Permission is granted to reproduce this publication for per...

Страница 3: ...STRUCTIONS FOR PUMP USE 7 5 3 CONNECTION TO THE POWER SUPPLY 7 6 TECHNICAL DESCRIPTION 6 1 IDENTIFICATION 8 7 UNPACKING CHECKING 7 1 PACKAGING 10 8 ASSEMBLING THE WATER BUTT PUMP 8 1 EXTENSION TUBES 11 9 OPERATING THE WATER BUTT PUMP 9 1 HORIZONTAL PUMPING DISTANCE 12 9 2 CONNECTION TO HOSE CHARGING THE BATTERY 12 9 3 INSTALLATION 13 9 4 POSITIONING THE PUMP 13 9 5 FLOW REGULATING 13 10 MAINTENANC...

Страница 4: ... hired out when the guarantee period is ninety days from the date of purchase The guarantee is extended to 24 months for parts only This guarantee does not apply to normal wear and tear nor does it cover any damage caused by misuse careless or unsafe handling alterations accidents or repairs attempted or made by any personnel other than the authorised Draper warranty repair agent Note If the tool ...

Страница 5: ...ection YES YES YES On time 30mins Off time 10mins WARNING The pump must be supplied through a residual current device RCD having a rated residual operating current not exceeding 30mA 4 3 HANDLING STORAGE Although these machines are small in size care must still be taken when handling and lifting Dropping these machines will have an effect on the accuracy and may also result in personal injury This...

Страница 6: ... inlet The area being pumped should be kept clear and nobody should enter the area while pump is operating IMPORTANT PLEASE READ BEFORE USE The following additional instructions must be followed at all times Failure to do so could invalidate the guarantee of this submersible water pump Clean water pumps are NOT suitable for use in dirty water NOTE The pump should be suspended using a rope or chain...

Страница 7: ...Never operate the pump dry 5 The area being pumped should be kept clear nobody should enter area while pump is operating THE FOLLOWING ADDITIONAL INSTRUCTIONS MUST BE FOLLOWED AT ALL TIMES FAILURE TO DO SO COULD INVALIDATE THE GUARANTEE OF THIS SUBMERSIBLE WATER PUMP 1 The float switch must be clamped in position using cable clamp recess see page 9 fig 10 2 Clean water pumps are not suitable for u...

Страница 8: ...ion piece Male hose connector pump outlet Hose Flow control and On Off switch Solar Panel Ground spike Charger not shown Extension pipe connection Filtered inlet Straight extension pieces Curved extension piece Male hose connector pump outlet Hose Flow control and On Off switch Charger not shown Stock No 38241 Stock No 36376 ...

Страница 9: ...9 6 TECHNICAL DESCRIPTION Stock No 36327 Extension pipe connection Filtered inlet Straight extension piece 2 Curved extension piece Male hose connector pump outlet Moulded plug cable Float switch ...

Страница 10: ... or missing please contact the Draper Helpline the telephone number appears on the Title page and do not attempt to use the product The packaging material should be retained at least during the guarantee period in case the machine needs to be returned for repair Warning Some of the packaging materials used may be harmful to children Do not leave any of these materials in the reach of children If a...

Страница 11: ...NSION TUBES FIGS 1 2 Attach the straight extension piece to the threaded spigot by tightening clockwise Ensure seal is installed correctly to achieve a water tight connection Screw the curved extension piece onto the straight extension piece by tightening ring FIG 1 FIG 2 8 ASSEMBLING THE WATER BUTT PUMP ...

Страница 12: ...g head of 3M equals 4M x 10 40M approximate pumping distance 9 2 CONNECTION TO HOSE FIGS 3 4 Make connection to the pump outlet with a quick connector on a length of hose On the other end of the hose connect an appropriate accessory suitable for the intended application CHARGING THE BATTERY 36376 38241 only To charge the battery connect the transformer plug adaptor to the charging port on the batt...

Страница 13: ...arge topped up actual charge applied to battery depends on available sunlight and suitable positioning of the solar panel On occasions of low sun or sunlight not directly striking the solar panel the use of the mains charger may be required to complete the charging of the battery 9 4 POSITIONING THE PUMP FIGS 6 7 When submersing or lifting the pump it is necessary to use a rope or chain this must ...

Страница 14: ...hazard 10 1 FILTER REMOVAL FIGS 9 10 From time to time it will be necessary to remove and clean replace the inlet filter With the pump disconnected from the power supply turn the unit over to expose the base Release clips and to remove filter base exposing filter as shown Remove the filter and rinse thoroughly with clean water Install the filter and secure the filter base Never use the pump with t...

Страница 15: ...water level where applicable 2 Clean 3 Straighten hose Problem Cause Remedy 1 Fuse 2 Battery is not charged 3 Other 1 Reset replace time delay fuse or circuit breaker 2 Charge the battery 3 Return to service agent Pump stops running due to thermal overload coming into operation 1 Solid jammed in pump 2 Excessive water temperature 3 Pump ran dry 1 Raise water level where applicable Clear jammed sol...

Страница 16: ...ed of according to national regulations Contact your local authority for details of collection schemes in your area In all circumstances Do not dispose of power tools with domestic waste Do not incinerate Do not abandon in the environment Do not dispose of WEEE as unsorted municipal waste Waste Electrical Electronic Equipment 16 ...

Страница 17: ... Waste Electrical Electronic Equipment 17 13 EXPLANATION OF SYMBOLS 13 1 EXPLANATION OF SYMBOLS WEEE Do not dispose of Waste Electrical Electronic Equipment in with domestic rubbish ...

Страница 18: ...18 NOTES ...

Страница 19: ...19 NOTES ...

Страница 20: ...Desk 023 8049 4333 Website www drapertools com E mail sales drapertools com Sales Fax 023 8049 4209 General Enquiries 023 8026 6355 Service Warranty Repair Agent For aftersales servicing or warranty repairs please contact the Draper Tools Helpline for details of an agent in your local area YOUR DRAPER STOCKIST KCDH180815 ...

Отзывы: