3. Specification
Stock No.
13818
Part No.
501G
Wood Test
Compound wood, thickness 10mm.
Metal Test
Diameter 20mm, Iron pipe
(depth 25mm max.)
AC Voltage test.
AC 220V Electric wire,
(depth 25mm max.)
Ambient condition.
-20°C to 60°C below 80% RH
Battery
9V, PP3
4. Product Identification
4.1 Product Overview
(1)
Stud detection face
(2)
Voltage/metal detection face
(3)
Stud indicator (red)
(4)
Stud indicator (green)
(5)
Stud sensitivity dial
(6)
Selector switch
(7)
Voltage/metal sensitivity dial
(10)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(11)
(12)
(13)
(14)
(1)
(2)
(8)
Power indicator (green)
(9)
Voltage/metal indicator (red)
(10)
Battery compartment cover
(11)
Stud detector trimmer
(12)
Voltage/metal detector trimmer
(13) Buzzer
(14)
AC voltage detection adjuster
(Factory adjustment only;
DO NOT tamper with this setting)
5. Health and Safety Information
• Read this manual in full before using this product.
• This device is intended for use as a guide
ONLY.
− Lack of response from the detector does not guarantee the
absence of metal, currents or wall studs.
− Caution must still be exercised when working in walls and other
blind surfaces.
•
DO NOT immerse this device in water or allow the battery to come
into contact with liquids.
•
DO NOT abuse, mutilate or burn the battery.
• Check the device carefully before use.
−
DO NOT use this product if it is damaged in any way or there is
evidence of battery leakage.
WARNING! This device emits a loud audible tone. Placing your ear over
the buzzer openings may cause hearing damage.
6. Operation and Use
Install a 9V PP3 battery (supplied) before use; see
7.2 Replacing the
Battery.
6.1 AC Voltage and Metal Detection
1. Hold the unit and rotate the voltage/metal sensitivity dial (7) fully
downwards.
1
Fig.
2. Move the selector switch (6) to the
AC Voltage/Metal Detector
position; the power indicator (8) should illuminate.
Important: Ensure that the device is not positioned near any metal
objects or current-carrying conductors when you switch it on.
3. Rotate the sensitivity dial (7) upwards until the metal/voltage
indicator illuminates and the audible tone sounds, then reverse the
dial gently until the indicators switch off.
4. Hold the device so that the voltage detection face (2) is flush with the
wall and move it sideways across the surface.
(7)