Hydra SprayTrax Manual
8
Chemical Mixing Procedure
Maintenance & Cleaning
1.
Periodically check the pump oil level
(G)
If it is below the indication, add oil though
the filler (H). Oil should be changed after
the first 50 hours of operation. Use 10 w 30
oil, preferrably non-detergent.
2.
Periodically lubricate the grease fittings
on the wheels
with a good grade of
bearing grease to extend the wheel
bearing life.
3.
Replace the spray gun tip every season.
As the hole in the tip gets larger the spray
pressure drops and degrades the quality
of the spray. (K)
4.
Thoroughly clean the in?line filter, tank
and machine on a weekly basis.
5. To drain tank, rotate the drain valve (L.)
90° allowing flow from the drain hose. To
completely drain tank, remove the lower
housing of the in-line filter (M).
*After
draining, clean the filter, replace the
housing and close the drain valve (L) to
ensure that upon refilling the tank? the
chemical will not drain out of the unit.
H.
G.
K.
L.
M.
1. Fill the sprayer tank at least 3/4 full with water
ONLY
.
2. Dilute (mixing to dissolve) chemicals with water in a 5 gallon bucket. Never put
concentrated chemical formulations directly into the tank without diluting with water.
3. Start sprayer with pressure regulator in
START
(priming) position to beginagitation process
prior to adding chemical to sprayer tank.
4. Pour chemical and water mixture (slurry) into the sprayer tank, filled 3/4 full of water, after
agitation has begun.
5. Fill remainder of sprayer tank with water.
Содержание Hydra SprayTrax
Страница 1: ...Owners Manual Model HYDRA ST50 Model HYDRAG ST50 Model HYDRAG ST100 Hydra SprayTrax...
Страница 9: ...Hydra SprayTrax Manual 10 SprayTrax Plumbing Hose Reel and Spray Gun Assembly Motor not shown...
Страница 11: ...Hydra SprayTrax Manual 12 SprayTrax Spray Gun...
Страница 13: ...Hydra SprayTrax Manual 14 MSO40E Crank Case and Inlet Valve...
Страница 15: ...Hydra SprayTrax Manual 16 MSO40E Pressure Regulator Valve...
Страница 19: ...Notes Hydra SprayTrax Manual 20...