Overvoltage Protection

If the 

PS-7 

regulator section should fail or one of the pass tran-

sistors should short, the unit will automatically shut down. If the
DC output voltage should soar above 16 VDC, an SCR crowbar
clamps the output to ground to protect the load and open the pri-
mary fuse. 

This fuse should b e  replaced with another of the same

type and rating after determining the cause of the overload.

Line Voltage Programming

The PS-7 comes factory set for 120 VAC 50-60 Hz operation. To
change the primary input range, simply remove the four screws
holding the programming plate. Refer to Figure 2. As an example,
suppose the line voltage measured 200 VAC. Remove the plate
and slide the voltage switch to 200/240. Then slide the HI/LO
switch to LO. Rotate the plate until 200 shows up in the window
and the LO switch fits through its locator hole. Reinstall the four
screws. If 200 or 240 VAC operation is desired, he 

sure to replace

the fuse with a 

amperc  type M  TH fuse.

100

120

-lO% 50-60 Hz

Hi Lo

200 240 Range:108-132vac

Hi Lo

-lO% 50-60 Hz

Range:90-110vac

100 120 -l0% 50-60 Hz

Hi Lo 200

240

Range:216-264vac

100 120 -lO% 50-60Hz

Hi Lo 200

240

Range:180-220vac

Fig. 2-PS-7 Line Voltage Programming

1 0 - 8 - 7 9