MM806 MODULATION MONITOR

6     Front Panel Controls and Indicators

        F1        F2                  F3                   F4                            F5

F4 - VIDEO Modulation
This meter indicates a percentage of video modulation for
the selected channel.  The Desired level is 87.5%.  Adjust
the video gain of the modulator being monitored to obtain
a reading of 87.5%.

F5 - AUDIO Modulation
This meter indicates a percentage of FM deviation of the
monitored channel.  100% is equal to 25 kHz peak
deviation, the NTSC standard in the U.S.A.

For example:
Setting for CATV channel "25"-

Figure 1

For example:
Setting for CATV channel "125"-

2

5

CATV

MODE

CATV +100

CHANNEL

BCTV

2

5

CATV

MODE

CATV +100

CHANNEL

BCTV

F1 - POWER Indicator
Lights when the unit is connected to the required source
of AC power.

F2 - Mode Switch
Sets the type of channel, Off-Air or CATV.  The third
position sets a leading “1” for CATV channels from 100
through 125.  See also Item F3 for setting the channel
number.

F3 - Channel Number Switch
Sets the received channel number for off-air TV channels
02 through 69 or for CATV channels 02 through 125.  See
also Item F2 which sets the type of channel (Off-Air or
CATV) and sets the leading “1” for CATV channels 100
through 125.

Содержание MM806

Страница 1: ...Instruction Manual is a registered trademark of the R L Drake Company Copyright 2002 R L Drake Company P N 3852398B 3 200 Printed in the U S A MM806 NTSC Modulation Monitor...

Страница 2: ...be moved with care Quick stops excessive force and uneven surfaces may cause the product and cart combination to overturn The lightning flash with arrow head symbol within an equilateral triangle is i...

Страница 3: ...is grounded so as to provide some protection against voltage surges and built up static charges Article 810 of the National Electrical Code ANSI NFPA 70 provides information with regard to proper grou...

Страница 4: ...The unit is powered through the attached AC line cord by a nominal 115 VAC 60 Hz source of power 0 20 40 60 80 100 MODULATION 0 20 40 60 80 100 MODULATION 2 5 POWER CATV MODE CATV 100 CHANNEL VIDEO 10...

Страница 5: ...ors 54 806 MHz Off Air Channels 2 69 CATV Channels 2 125 10 to 35 dBmV VHF 8 dB UHF 10 dB VHF 65 dB UHF 50 dB 75 Ohms 1 0 Vp p nominal NTSC standard negative sync 75 Ohms Less than 5 Less than 5 degre...

Страница 6: ...l to 25 kHz peak deviation the NTSC standard in the U S A For example Setting for CATV channel 25 Figure 1 For example Setting for CATV channel 125 2 5 CATV MODE CATV 100 CHANNEL BCTV 2 5 CATV MODE CA...

Страница 7: ...wired AC power line outlet this cable grounds the instrument cabinet Connect to a nominal 115 VAC 10 60 Hz source Do not defeat the safety purpose of the attached line cord plug R1 RF INPUT Connector...

Страница 8: ...rever possible and some air movement is advisable in enclosed rack cabinets Excessive heat will shorten component life and system performance will be degraded without proper cooling 0 20 40 60 80 100...

Страница 9: ...25 427 25 433 25 439 25 445 25 451 25 Standard Standard Standard Standard Standard Alphanumeric Alphanumeric Alphanumeric Alphanumeric Alphanumeric Identification Identification Identification Identi...

Страница 10: ...e on file at R L DRAKE you will need to send proof of purchase to receive warranty service Typically a copy of the invoice from an R L DRAKE dealer will suffice The warranty is for the original owner...

Страница 11: ...repair anduseareimportanttoobtainproperperformancefromthisproduct Thereforecarefully read the Instruction Manual This warranty does not apply to any defect that R L DRAKE COMPANY determines is due to...

Страница 12: ...R L Drake Company 230 Industrial Drive Franklin Ohio 45005 U S A Customer Service and Parts Telephone 1 937 746 6990 Telefax 1 937 743 4576 World Wide Web Site http www rldrake com...

Страница 13: ......

Страница 14: ...n 500 Ohms 0 to 100 AM modulation 87 5 is set point 0 to 100 of 25 kHz peak FM deviation 115 VAC 10 60 Hz 10 Watts 00 C to 500 C ambient 19 W x 1 75 H x 4 D 4 3 lbs 2 0 Kg RF Input and Video Output ar...

Отзывы: