Caution Statements

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT
TO RAIN OR MOISTURE.
DO NOT OPEN THE CABINET, REFER SERVICING TO QUALIFIED PERSONNEL ONLY.

TO PREVENT ELECTRIC SHOCK, DO NOT USE THIS (POLARIZED) PLUG WITH AN EXTENSION
CORD RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY INSERTED TO
PREVENT BLADE EXPOSURE.

POUR PREVENIR LES CHOCS ELECTRIQUES, NE PAS UTILISER CETTE FICHE POLARISEE
AVEC UN PROLONGATEUR, UNE PRISE DE COURANT OU UNE AUTRE SORTIE DE
COURANT, SAUF SI LES LAMES PEUVENT ETRE INSEREES A FOND SANS EN LAISSER
AUCUNE PARTIE A DECOUVERT.

WARNING:

CAUTION:

ATTENTION:

A product and cart combination should be moved
with care. Quick stops, excessive force and
uneven surfaces may cause the product and cart
combination to overturn.

The lightning flash with arrow head symbol, within
an equilateral triangle, is intended to alert the user
to the presence of uninsulated "dangerous voltage"
within the product's enclosure that may be of
sufficient magnitude to constitute a risk of electric
shock to persons.

The exclamation point within an equilateral triangle
is intended to alert the user to the presence of
important operating and maintenance (servicing)
instructions in the literature accompanying
the product.

CAUTION

WARNING: TO PREVENT FIRE OR

ELECTRICAL SHOCK DO NOT

EXPOSE TO RAIN OR MOISTURE

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION: TO REDUCE THE RISK OF ELECTRIC

SHOCK

,

DO NOT REMOVE COVER

NO USER-SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED PERSONNEL

Содержание MM806

Страница 1: ...Instruction Manual is a registered trademark of the R L Drake Company Copyright 2002 R L Drake Company P N 3852398B 3 200 Printed in the U S A MM806 NTSC Modulation Monitor...

Страница 2: ...be moved with care Quick stops excessive force and uneven surfaces may cause the product and cart combination to overturn The lightning flash with arrow head symbol within an equilateral triangle is i...

Страница 3: ...is grounded so as to provide some protection against voltage surges and built up static charges Article 810 of the National Electrical Code ANSI NFPA 70 provides information with regard to proper grou...

Страница 4: ...The unit is powered through the attached AC line cord by a nominal 115 VAC 60 Hz source of power 0 20 40 60 80 100 MODULATION 0 20 40 60 80 100 MODULATION 2 5 POWER CATV MODE CATV 100 CHANNEL VIDEO 10...

Страница 5: ...ors 54 806 MHz Off Air Channels 2 69 CATV Channels 2 125 10 to 35 dBmV VHF 8 dB UHF 10 dB VHF 65 dB UHF 50 dB 75 Ohms 1 0 Vp p nominal NTSC standard negative sync 75 Ohms Less than 5 Less than 5 degre...

Страница 6: ...l to 25 kHz peak deviation the NTSC standard in the U S A For example Setting for CATV channel 25 Figure 1 For example Setting for CATV channel 125 2 5 CATV MODE CATV 100 CHANNEL BCTV 2 5 CATV MODE CA...

Страница 7: ...wired AC power line outlet this cable grounds the instrument cabinet Connect to a nominal 115 VAC 10 60 Hz source Do not defeat the safety purpose of the attached line cord plug R1 RF INPUT Connector...

Страница 8: ...rever possible and some air movement is advisable in enclosed rack cabinets Excessive heat will shorten component life and system performance will be degraded without proper cooling 0 20 40 60 80 100...

Страница 9: ...25 427 25 433 25 439 25 445 25 451 25 Standard Standard Standard Standard Standard Alphanumeric Alphanumeric Alphanumeric Alphanumeric Alphanumeric Identification Identification Identification Identi...

Страница 10: ...e on file at R L DRAKE you will need to send proof of purchase to receive warranty service Typically a copy of the invoice from an R L DRAKE dealer will suffice The warranty is for the original owner...

Страница 11: ...repair anduseareimportanttoobtainproperperformancefromthisproduct Thereforecarefully read the Instruction Manual This warranty does not apply to any defect that R L DRAKE COMPANY determines is due to...

Страница 12: ...R L Drake Company 230 Industrial Drive Franklin Ohio 45005 U S A Customer Service and Parts Telephone 1 937 746 6990 Telefax 1 937 743 4576 World Wide Web Site http www rldrake com...

Страница 13: ......

Страница 14: ...n 500 Ohms 0 to 100 AM modulation 87 5 is set point 0 to 100 of 25 kHz peak FM deviation 115 VAC 10 60 Hz 10 Watts 00 C to 500 C ambient 19 W x 1 75 H x 4 D 4 3 lbs 2 0 Kg RF Input and Video Output ar...