Description:

ASI input module for inputting an EAS program that is looped out of the master EH24A(ASI Out) 
(containing the SDE24EAS) and also for inputting low speed data for DTA channel mapping and 
codeupdating.

Usage:

Used in an EH24A to add DTA data or used in an EH24A, for EAS alert programming that is being sourced by 
a ‘master’ EH24A/SDE24EAS. 

SDE24 DUAL PROGRAM ENCODER MODULE

Composite video Inputs:

2 composite inputs, one for each program

Composite Video Input Level:

1 Volt p-p ± 3 dB

Audio Inputs, for 2 programs:

RCA type for L and R audio channels, 2 sets

Audio Input Level:

1 Vrms or 2 Vrms user selectable and user adjustable audio gain ± 15 dB

MPEG ENCODER

Program Filtering and Grooming:

Encoded programs may be disabled or sent to one or both output ports - ASI or QAM, user 
selectable. The output timing is restamped and null packets are managed as required.

Multiplexer:

Built in multiplexer circuitry combines the outputs of all enabled encoders in an EH24A into multiprogram 
transport streams, one to the QAM output and one to the ASI output.

MPEG Program Numbers:

MPEG program numbers in the output transport stream by default will be assigned sequentially, 
corresponding to the encoder number. The leftmost encoder input, as viewed from the rear panel, will 
be # 1. If the Ethernet remote access is used, the MPEG and virtual channel (major and minor) numbers 
may be user selected to any desired MPEG-legal numbers and program names, up to 7 characters in 
length, may be added.

ASI Output:

Any or all of the enabled encoders may be directed to the ASI output by means of the user selectable 
program filter. If EAS operation is used, this output can be assigned to loop the EAS alert program to 
additional EH24As. It can also loop DTA data.

Encode Format - #1 input:

MPEG2 or MPEG4 H.264, selectable

Encode Format - #2:

MPEG2 only

 Input Encoding Bitrate:

Constant Bitrate: 1 Mbps to 8 Mbps

Video Adjustments:

Brightness, Contrast, Saturation, Hue

SDE24EAS MODULE

EH24A CHASSIS

Specifi cations

Specifications subject to change without notice or obligation.

ANALOG INTERFACE

Selectable Types:

AC-3 Dolby digital Stereo OR MPEG1, Layer 2 (MP2)

Dolby Digital Encoder:

Manufactured under license from Dolby Laboratories.

Output bitrate:

User-selectable from Ethernet Control Interface; 128, 192, 320, 384 Kbps

AUDIO ENCODER

Output:

The output of each SDE24 module is connected internally to the multiplexers that are included in the 
EH24A chassis.

Description:

MPEG2 Encodes NTSC EAS alert program. Used to add EAS to an EH24A system. Can be used for SCTE18 
operation, for program replacement in all SDE24 encoders, or both.

Usage:

Only one SDE24EAS is required per headend. Must be inserted into slot number 6 of the master EH24A 
chassis.

ASII MODULE

Содержание EH24A

Страница 1: ...anual EH24A Encoder Host SDE24 SD Dual Encoder is a registered trademark of the R L Drake Holdings LLC Copyright 2012 R L Drake Holdings LLC P N 651232200A Printed in U S A Rev1 20121220 EH24A 1002510A SDE24 1002514 ...

Страница 2: ...undry tub in a wet basement or near a swimming pool and the like Table of Contents Caution Important Safety Instructions WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE DO NOT OPEN THE CABINET REFER SERVICING TO QUALIFIED PERSONNEL ONLY CAUTION TO PREVENT ELECTRIC SHOCK DO NOT USE THIS POLARIZED PLUG WITH AN EXTENSION CORD RECEPTACLE OR OTHER OUT...

Страница 3: ...unding electrode 14 Power Cord Protection Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them paying particular attention to cords at plugs convenience receptacles and the point where they exit from the product 15 Lightning For added protection for this product during a lightning storm or when it is left unattended and unu...

Страница 4: ...anel will be 1 If the Ethernet remote access is used the MPEG and virtual channel major and minor numbers may be user selected to any desired MPEG legal numbers and program names up to 7 characters in length may be added ASI Output Any or all of the enabled encoders may be directed to the ASI output by means of the user selectable program filter If EAS operation is used this output can be assigned...

Страница 5: ...ity 5 ppm Output Level Accuracy 1 dB Output Level 45 dBmV to 62 dBmV adjustable Output Level Accuracy 1 dB Phase Noise 101 dBc 10 kHz offset Broadband Noise Less than 12 dBmV 6 MHz BW 12 MHz Output Impedance 75 Ohms RL 14 dB or better 54 1002 MHz Spurious outputs 60 dBc from 40 to 1000 MHz GENERAL AC Power 90 to 264 VAC 47 63 Hz 70 W maximum Operating Temperature 0 deg to 50 deg C FCC Approvals Th...

Страница 6: ...eams can be generated If MPEG4 H 264 encoding is desired each SDE24 module can encode one program to an H 264 output stream Another option is to encode one program in MPEG2 and the second program in H 264 The SDE24 accepts either NTSC or PAL video inputs SDE24EAS This is a specialized version of the SDE24 to be used when EAS is needed to encode the EAS program EAS mode is provided by one of 2 meth...

Страница 7: ...o with EAS program video on all EH24A encoded program PIDs is provided Either method or both may be operator selected Program Filtering and Multiplexing The EH24A contains transport stream multiplexers that can multiplex any or all of the program streams from the encoders The user may select what programs from the encoders to include in the QAM output channel and also the user can select independe...

Страница 8: ...ns to change the value of a viewed parameter setting The unit must be in the program mode in order for these buttons to become active for changing a parameter setting If the unit is not in the program mode pressing the Up button will show the version number of the EH24A firmware Repeatedly pressing the Down button will toggle between showing the Mbits S for QAM and the Mbits S for ASI F4 ENTER But...

Страница 9: ...onnection to the mains AC power source The removable line cord allows for operation in various countries Use an appropriate cord for your needs that has been recognized by a certified safety agency This unit is usually supplied with a cord for USA operation on 120 VAC The power supply automatically accepts a mains supply from 90 to 264 VAC 47 to 63 Hz Power consumption will vary depending on the n...

Страница 10: ...nit has an assigned IP address you can view and change its settings from a web browser For instance if the unit s IP address were 10 0 0 1 you would load http 10 0 0 1 in your web browser to view and configure your EH24A The username and password required to log into the unit are both set from the front panel Once the EH24A web server has been loaded from your browser you should see the login dial...

Страница 11: ...u to set each encoder s individual parameters Select an encoder module from the drop down menu and the appropriate setting selections will be displayed Ethernet Control Interface Configuration Continued Figure 2 EH24A Encoders Tab ...

Страница 12: ...ed along with the Major and Minor channel numbers If one part virtual channel numbers are desired the PSIP Mode must be set to CVCT and the Minor number for each channel should be set to 0 The Output tab provides an interface to set all modulator output settings for the unit A screenshot of this tab is shown in Figure 4 This tab selects the DTA and EAS modes channel bitrates QAM settings and the m...

Страница 13: ...13 Ethernet Control Interface Configuration Continued Figure 4 EH24A Output Tab ...

Страница 14: ... you have received a new firmware image for the unit click on the Choose File button and select the provided firmware click Upload to initiate the update After a few minutes the unit will restart with the new firmware If a power loss occurs during update the unit will recover automatically if the firmware upload was not completed it may be necessary to re initiate the update process once power is ...

Страница 15: ...age 10 SETUP EH24A USER NAME Variable this sets the username for the ethernet control interface authorization this field is case sensitive PASSWORD Variable this sets the password for the ethernet control interface authorization this field is case sensitive for first time setup the default USER NAME is admin and the default PASSWORD is EH24 HOST NAME Variable this sets the display hostname for the...

Страница 16: ... will only appear if DTA EAS is set to MASTER and EAS MODE is set to enable SCTE18 This menu allows the user to determine on which MPEG program number the EAS information will appear The choices are 1 thru 65535 EAS MAJOR CHANNEL Note that this menu will only appear if DTA EAS is set to MASTER and EAS MODE is set to enable SCTE18 This menu allows the user to select on which major channel the EAS i...

Страница 17: ...ng these two menus RF LEVEL Select the desired RF output signal level The available range is between 45 dBmV and 56 dBmV selectable in 0 5 dB steps The output accuracy is 1 dB SETUP ENDODER xx ENCODER SELECT The LEFT and RIGHT buttons allow the user to scroll through the encoder numbers for each encoder installed in the EH24A as well as the EH24A itself Use the LEFT and RIGHT buttons to select the...

Страница 18: ... the first module 3 and 4 the second module 11 and 12 the sixth module etc If an encoder is installed but you don t plan to use it be sure to choose the DISABLED choice for any such encoders 8 Press the right arrow again after setting the 12th encoder This should produce the QAM MGT VCT screen Usually select TVCT by using up or down arrows 9 Press right arrow again and observe the QAM MODE screen ...

Страница 19: ...completed EH24A settings on page 14 you are now ready to setup each individual encoder 19 Press ENTER for 3 seconds to enter program mode Observe flashing display 20 Use left or right ENCODER SELECT buttons to choose one of the installed encoders 21 To set the encoder to typical default settings press the up arrow down arrow and ENTER all at the same time Hold the three buttons in for several seco...

Страница 20: ... all other EH24As being Slaves These setups require different configurations of the EH24A with the SDE24EAS and ASII plug in modules If set as a Slave Unit Module 6 must always be an ASII module If set as the Master unit then there are 4 possible configurations for what needs to be plugged into the Module 6 and the Module 5 slots DTA MODE EAS MODE Module 6 Plug in Module 5 Plug in DISABLED SCTE 18...

Страница 21: ...21 CATV Channel Frequencies TABLE 1 CATV ...

Страница 22: ...22 Broadcast TV Channel Frequencies TABLE 2 BCTV ...

Страница 23: ...d to know the specifics of any other equipment connected to the unit When calling please have the unit up and running near the phone if possible Our technician s will likely ask certain questions to aid in diagnosis of the problem Also have a voltmeter handy if possible R L DRAKE also provides technical assistance by e mail info solidsignal com Many of the products that are sent to us for repair a...

Страница 24: ...4 If You Need To Call For Help continued If the unit is out of warranty call Solid Signal at 877 312 4547 and we will help you with the best possible option This may include replacing the unit completely ...

Страница 25: ...tainer or equivalent fully insured and shipping charges prepaid Correct maintenance repair and use are important to obtain proper performance from this product Therefore carefully read the Instruction Manual This warranty does not apply to any defect that R L DRAKE HOLDINGS LLC determines is due to 1 Improper maintenance or repair including the installation of parts or accessories that do not conf...

Страница 26: ...Distrbuted by Solid Signal www solidsignal com 877 312 4547 ...

Отзывы: