background image

9

INSTALLATION OF THE EXHAUST FILTER

Flat screw

driver

90˚ medium
abs elbow

Activac 1
exhaust filter

Flat screw

driver

Collar

Collar

Содержание Atomik

Страница 1: ... Open the lid of the vacuum cleaner before using OWNER S MANUAL ...

Страница 2: ...lectrical power to the wall area before installing Unplug before attempting maintenance or cleaning Unplug from electrical outlet when not in use and before servicing Do not use with damaged cord or plug Do not operate the vacuum cleaner if damaged Do not modify any part of the vacuum cleaner This vacuum cleaner is intended to be in a vertical position or floor mount position Never vacuum flammabl...

Страница 3: ...d page 7 Unit installation page 8 Installation of the Activac1 exhaust filter page 9 Installation ready to use page 10 Installation on a piping network page 11 Electrical installation page 12 Maintenance cleaning procedures page 13 WEEE directives page 14 Trouble shooting page 15 Kits A B C page 16 Accessories Filters Dust bags page 17 Warranty page 18 ...

Страница 4: ...3 TOOLS REQUIRED Phillips screw driver star Flat screw driver 2 25 57 mm 0 5 12 5 mm Measuring tape Hole saw Hand drill Mitre box saw or Pipe cutter Pair of pliers Pair of cutters ...

Страница 5: ...nal 240V GreenLED On Off button On I position Off O position 24 volt Clamps 2 x Dust bags One without zipper one with zipper 8 20cm diam Polyester filter 4 x collar Activac 1 exhaust filter Utility inlet PVC coupling 90 medium ABS elbow Owner s manual 4 x 1 screws 1 foot 30cm 24 volt wire with connectors Wall bracket ...

Страница 6: ...quipment for the installation of the unit Keep it near the unit 2 Make sure the polyester filter and dust bag are properly installed 3 Replace the lid on the unit and attach the clamps Open the vacuum cleaner before using Remove the Drainvac Atomik vacuum cleaner and the equipment from the packaging ...

Страница 7: ...6 15 5 39 5cm 9 75 24 75cm 11 28cm UNIT DIMENSIONS Front view Side view ...

Страница 8: ...n 1 2 5cm Min 12 30 5cm Min 9 22 75cm Min 12 30 5cm Min 18 45 75cm MINIMUM SPACE REQUIRED TO INSTALL THE UNIT Front view Side view Install the unit near an electrical outlet 120 volt 15amps 240 volt 16amps ...

Страница 9: ...utters 2 Fasten the wall plate to the wall using the 4 x 1 screws included with the unit 3 Lift the unit and install the top part A of the unit bracket behind the top part of the wall plate At the same time install the bottom part B of the unit bracket inside of the bottom part of the wall plate Cut strap with the pair of cutters Phillips screw driver star ...

Страница 10: ...9 INSTALLATION OF THE EXHAUST FILTER Flat screw driver 90 medium abs elbow Activac 1 exhaust filter Flat screw driver Collar Collar ...

Страница 11: ...1 2 10 PVC coupling DRAINVAC ATOMIK READY TO USE 2 x Collar Utility inlet 1 foot 30cm 24 volt wire with connectors Flat screw driver Phillips screw driver star ...

Страница 12: ...11 INSTALLATION ON A PIPING NETWORK In a condo in a garage in a RV in the mecanic room 24 volt wire Example RV installation Power outlet ...

Страница 13: ...t must be installed close to the unit We strongly recommend installing an electrical circuit that will be used only by the unit North American model ATOMIK6 require an 15 amps 120 volt circuit International model ATOMIK60 require an 16 amps 240 volt circuit Also plan the 24 volt between the unit the piping system and the inlets ELECTRICAL INSTALLATION ...

Страница 14: ... periodically This will stabilise the efficiency of the unit and will cut down from 5 to 6 times the maintenance of your unit Cleaning procedure 1 Detach the clamps remove the lid from the unit 2 Remove and discard the dust bag and the polyester filter If you use a dust bag with a zipper you can re use it a few time all depending on the use Image A The misuse of this bag may invalidate the warrant...

Страница 15: ...at the use of new resources and amount of waste going for landfill be minimized The WEEE Directive stipulates that the supplier should collect the used item without cost to you Please inform the supplier of your wish to have the old appliance collected when ordering the new replacement If you wish to dispose of the appliance yourself do not mix it with unsorted municipal waste The crossed out whee...

Страница 16: ...tween the two screws of the 24 volts circuit plate using a piece of metal ex Screw driver Image E If the unit starts the 24 volt wire is either cut OR unplugged from one of the wall mounted air inlet valves If the system still do not start after steps 1 2 and 3 the printed circuit is defective Call your dealer PROBLEM The unit will not stop Check the 24 volt circuit as follows Disconnect one of th...

Страница 17: ... kit TGA30 6 Econo kit KIT130C DELUXE kit 20 6m extensible hose tools hose hanger and handle 30 9m regular hose brush tools kit hose hanger telescopic handle 30 9m on off hose brush tools kit accessory hanger telescopic handle ...

Страница 18: ...ustpan installation kit Extra screws wall hanger 1 screws 1 25 30mm All illustrations specifications colors and photographs shown may vary While Drainvac International takes care to ensure that the information contained in this publication is accurate it cannot guarantee complete accuracy Drainvac International is not responsible for errors or omissions contained in this publication ...

Страница 19: ...cial warranty Excludes the motor brushes Labor at the dealer store or plant Freight at the customer s expense Have purchase invoice Warning the service call made by dealer is at the customers expense If you wish to speak to a service agent please contact your retailer or Drainvac International Inc Monday to Friday from 9am to 4pm eastern time at T 1 800 408 1448 450 467 1448 F 1 877 408 2225 450 4...

Страница 20: ... com OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL 4 2011 th ...

Отзывы: