15.0 Configuring the Time Source (SNTP)
The time and date can be entered into the Horizon system. This is maintained for as long as power is
applied to the system. If power fails, then all timing information is lost. An accurate clock is necessary
for time stamping entries in the events and performance logs.
To maintain the time and date in the system, five network sources of timing information are configurable.
Either an Internet time source or an NTP server on your network may be used.
Simple Network Time Protocol (sntp) is used.
Five time sources are configured by default. Each time source is indexed 1 to 5. Indices 1 and 2 are
from Industry Canada servers, 3 and 4 are from U.S. Navy servers and 5 is from a Swiss server. Any
other time sources can be configured. The timing information is polled every 60 minutes.
Table 15-1 Time Sources
Index
Stratum
Source
IP Address
Source
1
2
199.212.17.15
Industry Canada
2
2
199.212.17.20
Industry Canada
3
1
192.5.41.40
U.S. Navy
4
1
192.5.41.209
U.S. Navy
5
2
129.132.2.21
Switzerland