Bandwidth Management
59
Horizon Compact Plus Release 1.0.1
Wireless Ethernet Product User Manual
– Volume 2
Required Action
Steps
View the current record
This command returns the values currently being accrued, but not yet
written to a record. It shows the time left in the sampling period (1319
seconds in the example below) before the running average is valid (the
running average period must elapse before the running average is valid).
The record will be written to flash in 86400s
– 2281s = 84119s.
Sequence:
get bandwidth record current
press Enter
The system responds:
Current Running-Average Bandwidth Utilization: 90% (valid in
1319s)
Maximum Running-Average Bandwidth Utilization (averaging
period = 3600s):
Date and Time: not available (ready in 1319s)
Utilization: 0%
Elapsed time in reporting period (period = 86400s): 2281s
Instantaneous Utilization Counts were (average sample
duration 1046ms):
10%: 2048 (2143 seconds)
20%: 2048 (2143 seconds)
30%: 2044 (2138 seconds)
40%: 2037 (2131 seconds)
50%: 2036 (2130 seconds)
60%: 1951 (2041 seconds)
70%: 1950 (2040 seconds)
80%: 1947 (2037 seconds)
90%: 1944 (2034 seconds)
95%: 1935 (2024 seconds)