How Does the BMS Protect the Batteries?

 

All Battle Born Batteries come with a built-in battery management system (BMS) that protects the cells from many 
strenuous circumstances to protect the life cycles of the cells and your electrical system from potential damage. 
The BMS protects against the following conditions: 

High Voltage Disconnect (> 14.7V)

 

If an individual cell voltage exceeds a prescribed threshold during charging, the BMS will prevent a charge current from 
continuing. Discharge is always allowed under this condition. If the batteries have not been balanced for a long time, 
high voltage disconnect could occur at a lower voltage. The batteries will rebalance after several full charges. 

Low Voltage Disconnect (< 10V)

 

If an individual cell falls below a prescribed threshold during discharge, the BMS will prevent further discharge. Although 
the battery is in “low-voltage disconnect” mode, it will still allow a charging current. 

NOTE: Many chargers must detect a voltage over 10V to send a charge to the battery. Please be aware that some chargers may not sense a battery in low voltage 
disconnect and you may need to jump with a 12V source to “wake up” the battery. You should jump your battery within 24hrs of entering low voltage disconnect 
otherwise you risk damaging your battery and voiding the warranty. 

High Temperature Charging and Discharging (> 135°F/57.2°C)

 

The BMS will not allow a charging or discharging current if the internal temperature of the battery has reached 135°F 
(57.2°C). 

Low Temperature Charging (< 25°F/-3.9°C)

 

The BMS will not allow a charging current under 25°F (-3.9°C) but will continue to discharge down to -4°F (-20°C). 

High Current Discharge Surges

 

dŚĞ D ^ŝŶŽƵƌ

100Ah batteries allow 

ĨŽƌ

100A cont

ŝŶƵŽƵƐ

a current 

of

 

200

A

 

for 30s,

 and

 

ŐƌĞĂƚĞƌƚŚĂŶϮϬϬ

 for 0.5s. 

After a high current disconnection, the battery will automatically reconnect after 5 seconds. 

Short Current Discharge Surges 

Our BMS has built-in short circuit protection. If the short circuit protection is tripped, the BMS will shut the battery down 

and will remain disconnected until you remove the battery cables. While the battery cables are disconnected, we 

suggest taking the voltage of the battery with the use of a voltmeter. If it reads above 10V, reconnect the battery cables. 

If you are unsuccessful at obtaining a voltage reading above 10V, please give our technical support team a call.

Balancing of Cells

 

A passive balancing process is activated 
by the BMS at the top of each charge cycle 
when the battery voltage exceeds around 
14.2V. This ensures that all the cells 
remain at the same state of charge, which 
helps pack longevity and performance. 

How to Properly Size Cables   

for a System Install

 

When considering cable sizing there are a 
few factors to consider. First, what is the 
size of the load you are powering with the 
battery bank? Second, how far away from the battery 
is the load? You can do voltage drop calculations to see if you need to step 
up your cable size. Fig. 5 is a chart to use for reference. Do keep

i n mind that 

cables are only capable of carrying a certain amperage and you should verify 
the specifications of your cable and the power draws before

ŝŵƉůĞŵĞŶƚŝŶŐ

ƚŚĞŵŝŶƚŽLJŽƵƌƐLJƐƚĞŵƚŽĂǀŽŝĚƉŽƚĞŶƚŝĂůĨĂŝůƵƌĞƐĂŶĚĚĂŵĂŐĞ͘

Figure 5: As a rule of thumb, you can use these numbers as a guideline.

 

Cable QR Code 

Содержание Battle Born BB10012

Страница 1: ...ragonfly Energy Battle Born Batteries Model BB10012 BB10012H 100Ah 12V Deep Cycle LiFePO4 Battery Manual and Installation Guide Dragonfly Energy Corp Phone 855 292 2831 Email info battlebornbatteries com ...

Страница 2: ...struction manual prior to use and installation Table of Contents What is in the Box 2 What Do I Need for Installation 3 Connecting Load Specified Cables to the Batteries 3 Connecting the Batteries in Parallel 4 How to Properly Charge the Batteries 5 How to Properly Size Cables for a System Install 6 How to Incorporate Fuses Into System Install QR for Blog 7 How to Properly Store Batteries QR for B...

Страница 3: ...ive 2 Determine which finishing hardware set you will use Verify that your bolt can fully seat into the nylok insert of the nut If multiple lugs are used longer bolts may be required for the bolt to fully seat into the nylok insert of the nut 3 Connect your cable lugs to your battery terminal with the previously identified finishing hardware set Make sure to connect your positive load specified ca...

Страница 4: ...hese are labeled and color coded red for positive black for negative 2 Determine the appropriate finishing hardware set you will use Verify that your bolt can fully seat into the nylok insert of the nut If multiple lugs are used longer bolts may be required for the bolt to fully seat into the nylok insert of the nut 3 Make the proper cable connections to the positive of the first battery Please re...

Страница 5: ...roper cable connections to the negative of the first battery Please reference Fig 1 for the proper order of hardware 5 When connecting to your battery terminals DO NOT finger tighten Use a torque wrench to torque your hardware to the specification of 9 to 11 ft lbs Failure to adequately secure connections can result in severe damage and will void your warranty 6 Connect the other end of your cable...

Страница 6: ...ing current under 25 F 3 9 C but will continue to discharge down to 4 F 20 C High Current Discharge Surges dŚ Ğ D ŝ Ŷ Ž Ƶ ƌ 100Ah batteries allow Ĩ Ž ƌ 100A contŝ Ŷ Ƶ Ž Ƶ Ɛ a current of 200A for 30s and ŐƌĞĂ ƚĞƌ ƚŚ Ă Ŷ Ϯ Ϭ Ϭ for 0 5s After a high current disconnection the battery will automatically reconnect after 5 seconds Short Current Discharge Surges Our BMS has built in short circuit protecti...

Страница 7: ...utors or dealers to be free of defects for a period of 10 years the Warranty Period from the date of sale as determined by either the customer s sale receipt the shipping invoice and the battery serial number with proof of purchase Within the first 8 years of the Warranty Period subject to the exclusions listed below the Manufacturer will credit replace or repair if serviceable the Product and or ...

Страница 8: ...rchandise authorization RMA is issued Items 60 days past the original invoice will be reviewed at Battle Born s discretion Returns will not be accepted without an RMA number which can be obtained by filling out the return form at https battlebornbatteries com returns To avoid being charged restocking fees review the full return refund policy at https battlebornbatteries com terms conditions return...

Отзывы: