中龙集团
Dragon Group China Limited
BIRD
®
running setting instead of the basic setting. The basic setting displays under the SP
parameter code.
When the meter is in the state of ldIE, the lower screen displays the basic setting.
2. Modification of parameters when the curve procedure runs.
a. When the meter runs, we can't modify the curve program parameter LC
,
r1, L1, d1, r2,
L2.d2
……
But other parameters can be modified and saved.
b. When the meter pauses, the modification of LC
,
r1,L1,d1,r2,L2.d2
……
is valid only in
this running, and not saved. Other parameters all can the modified and saved.
c. When the meter stops, LC
,
r1, L1, d1, r2, L2.d2
……
and other parameters can be
modified and saved.
d. What to do if there is a power-off while the meter is working? At this moment, the
meter will record and save the current parameter and running state. Once the power is on,
the meter will continue the program from this point, instead of restart from the beginning.
e. What to do when the curve program is over? Then the meter will deal with it according
to the settings of (P, End). When P.End is set at OFF, the meter stops outputting and the
programme is over.
The following chart only for reference
:
Содержание Bird AC-5K
Страница 18: ...Dragon Group China Limited BIRD www dragongroupchina com www chinaemall biz...
Страница 19: ...Dragon Group China Limited BIRD www dragongroupchina com www chinaemall biz...
Страница 26: ...Dragon Group China Limited BIRD www dragongroupchina com www chinaemall biz...
Страница 31: ...Dragon Group China Limited BIRD www dragongroupchina com www chinaemall biz...