background image

 

 

www.dragino.com

 

LSE01 LoRaWAN Soil Moisture & EC Sensor User Manual

 

  

21

 / 

30

 

2.10

 

Firmware Change Log 

Firmware download link: 

http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/

 

 
Firmware Upgrade Method: 

http://wiki.dragino.com/index.php?title=Firmware_Upgrade_Instruction_for_STM32_base_
products#Introduction

 

 
V1.0. 

Release

 

 

 

Содержание LSE01

Страница 1: ...EC Sensor User Manual Document Version 1 4 Image Version v1 0 Version Description Date 1 0 Release 2020 Apr 24 1 1 Add fix for rejoin issue on second packet trouble shooting 2020 May 30 1 2 Fix typo o...

Страница 2: ...www dragino com LSE01 LoRaWAN Soil Moisture EC Sensor User Manual 2 30 1 4 Add Battery Option 2021 Mar 17...

Страница 3: ...ata in Mydevices IoT Server 15 2 6 Frequency Plans 16 2 6 1 EU863 870 EU868 16 2 6 2 US902 928 US915 17 2 6 3 CN470 510 CN470 17 2 6 4 AU915 928 AU915 18 2 6 5 AS920 923 AS923 925 AS923 18 2 6 6 KR920...

Страница 4: ...www dragino com LSE01 LoRaWAN Soil Moisture EC Sensor User Manual 4 30...

Страница 5: ...for Mineral soil type It detects Soil Moisture Soil Temperature and Soil Conductivity and uploads the value via wireless to LoRaWAN IoT Server The LoRa wireless technology used in LES01 allows device...

Страница 6: ...www dragino com LSE01 LoRaWAN Soil Moisture EC Sensor User Manual 6 30...

Страница 7: ...Enclosure 4000mAh or 8500mAh Battery for long term use 1 3 Specification Measure Volume Base on the centra pin of the probe a cylinder with 7cm diameter and 10cm height Parameter Soil Moisture Soil C...

Страница 8: ...t has OTAA keys to join LoRaWAN network To connect a local LoRaWAN network you need to input the OTAA keys in the LoRaWAN IoT server and power on the LSE0150 It will automatically join the network via...

Страница 9: ...se the LG308 as a LoRaWAN gateway in this example The LG308 is already set to connected to TTN network so what we need to now is configure the TTN server Step 1 Create a device in TTN with the OTAA ke...

Страница 10: ...www dragino com LSE01 LoRaWAN Soil Moisture EC Sensor User Manual 10 30...

Страница 11: ...al 11 30 Step 2 Power on LSE01 Put a Jumper on JP2 to power on the device The Jumper must be in FLASH position Step 3 The LSE01 will auto join to the TTN network After join success it will start to up...

Страница 12: ...this value by 100 to get the percentage of moisture in the soil For example if the data you get from the register is 0x05 0xDC the moisture content in the soil is 05DC H 1500 D 100 15 2 3 3 Soil Tempe...

Страница 13: ...is less than 800uS cm 2 3 5 Decode payload in The Things Network While using TTN network you can add the payload format to decode the payload The payload decoder function for TTN is here LSE01 TTN Pa...

Страница 14: ...Any 06 4 Examples Set TDC If the payload 0100003C it means set the END Node s TDC to 0x00003C 60 S while type code is 01 Payload 01 00 00 1E TDC 30S Payload 01 00 00 3C TDC 60S Reset If payload 0x04F...

Страница 15: ...data once we have data in TTN we can use Mydevices to connect to TTN and see the data in Mydevices Below are the steps Step 1 Be sure that your device is programmed and properly connected to the netwo...

Страница 16: ...s 2 7 Frequency Plans The LSE01 uses OTAA mode and below frequency plans by default If user want to use it with different frequency plan please refer the AT command sets 2 7 1 EU863 870 EU868 Uplink 8...

Страница 17: ...to SF12BW500 925 1 SF7BW500 to SF12BW500 925 7 SF7BW500 to SF12BW500 926 3 SF7BW500 to SF12BW500 926 9 SF7BW500 to SF12BW500 927 5 SF7BW500 to SF12BW500 923 3 SF12BW500 RX2 downlink only 2 7 3 CN470 5...

Страница 18: ...5 SF7BW500 to SF12BW500 923 3 SF12BW500 RX2 downlink only 2 7 5 AS920 923 AS923 925 AS923 Default Uplink channel 923 2 SF7BW125 to SF10BW125 923 4 SF7BW125 to SF10BW125 Additional Uplink Channel OTAA...

Страница 19: ...o SF9BW125 2 7 7 IN865 867 IN865 Uplink 865 0625 SF7BW125 to SF12BW125 865 4025 SF7BW125 to SF12BW125 865 9850 SF7BW125 to SF12BW125 Downlink Uplink channels 1 3 RX1 866 550 SF10BW125 RX2 2 8 LED Indi...

Страница 20: ...www dragino com LSE01 LoRaWAN Soil Moisture EC Sensor User Manual 20 30 Dig a hole with diameter 20CM Horizontal insert the probe to the soil and fill the hole for long term measurement...

Страница 21: ...30 2 10 Firmware Change Log Firmware download link http www dragino com downloads index php dir LoRa_End_Node LSE01 Firmware Firmware Upgrade Method http wiki dragino com index php title Firmware_Upg...

Страница 22: ...d to use a high current short period transmit method The recommended minimum period for use of this battery is 5 minutes If you use a shorter period time to transmit LoRa then the battery life may be...

Страница 23: ...supports AT Command set in the stock firmware You can use a USB to TTL adapter to connect to LSE01 for using AT command as below Or if you have below board use below connection In the PC you need to...

Страница 24: ...ATZ MCU Reset AT TDC Application Data Transmission Interval Keys IDs and EUIs management AT APPEUI Application EUI AT APPKEY Application Key AT APPSKEY Application Session Key AT DADDR Device Address...

Страница 25: ...nter Downlink AT FCU Frame Counter Uplink AT JN1DL Join Accept Delay1 AT JN2DL Join Accept Delay2 AT PNM Public Network Mode AT RX1DL Receive Delay1 AT RX2DL Receive Delay2 AT RX2DR Rx2 Window Data Ra...

Страница 26: ...0 0 ENABLE Channel 0 63 1 902 3 902 5 902 7 902 9 903 1 903 3 903 5 903 7 Channel 0 7 2 903 9 904 1 904 3 904 5 904 7 904 9 905 1 905 3 Channel 8 15 3 905 5 905 7 905 9 906 1 906 3 906 5 906 7 906 9...

Страница 27: ...8 916 916 2 916 4 916 6 Channel 0 7 2 916 8 917 917 2 917 4 917 6 917 8 918 918 2 Channel 8 15 3 918 4 918 6 918 8 919 919 2 919 4 919 6 919 8 Channel 16 23 4 920 920 2 920 4 920 6 920 8 921 921 2 921...

Страница 28: ...apping Please see the Eight Channel Mode section above for details 5 2 AT Command input doesn t work In the case if user can see the console output but can t type input to the device Please check if y...

Страница 29: ...low Cause for this issue The fuse on LSE01 is not large enough some of the soil probe require large current up to 5v 800mA in a short pulse When this happen it cause the device reboot so user see rejo...

Страница 30: ...8500mAh battery 7 Packing Info Package Includes LSE01 LoRaWAN Soil Moisture EC Sensor x 1 Dimension and weight Device Size cm Device Weight g Package Size pcs cm Weight pcs g 8 Support Support is prov...

Отзывы: