List of materials

8

List of materials

Name

Order no.

Manufacturer

Gas transmitter and sensor type

According to customer requirements

Dräger

Aspirator system SAM 3100 / 3200

for a gas transmitter, comprising:

Dräger

Base plate, 500 mm x 500 mm, stainless steel

Dräger

Filter, fine filter 1 µm

38.PC1410PVDF-ISW

ISW

Flow meter with ring initiator, 
monostable, flow monitoring

15. DK 800 PV K 1-MO
6–60 l/h
10–100 l/h
25–250 l/h

Krohne

All system hoses are PTFE, screw connections are PVDF, system is installed on the base plate.

Additional equipment:

Gas sampling pump, not for Ex areas

PM21772-87 (N87 TTE)

ISW (KNF)

Gas sampling pump, for Ex areas

PM21773 -87 (N87 TTE Ex)

ISW (KNF)

Protective housing, 500 x 500 x 300 mm, 
plastic, filter mounted externally

KS 1453.600

Rittal

Protective housing, 500 x 500 x 300 mm, 
sheet steel, filter mounted externally

AE 1013.600

Rittal

Protective housing, 500 x 500 x 300 mm, 
stainless steel, for Ex areas, filter mounted externally

AE 1013.600

Rittal

3/2-way spherical valve, stainless steel

02.SS-42 GXS 6 mm

Swagelok

Ejector

01.710200.00VA

ISW

Regulating valve

70.159.625

Festo

Isolation amplifier 24 V DC

03.160312

Steel

Isolation amplifier 230 V AC

03.160321

Steel

Motor circuit protector 0 to 0.4 A

115.072732

Eaton

Содержание SAM 3100

Страница 1: ...Dr ger SAM 3100 3200 Sampling system Instructions for Use i...

Страница 2: ......

Страница 3: ...ystem with ejector unit 5 4 4 System with gas sampling pump 5 4 5 Circuit breaker option 5 4 6 Motor circuit protector option 6 5 Installation 6 5 1 Mechanical fastening 6 5 2 Installing gas lines 6 5...

Страница 4: ...ulty or incomplete parts is forbidden The appropriate regulations must be observed at all times when carrying out repairs on these devices or components 1 2 Definitions of alert icons The following al...

Страница 5: ...ulating valve on the flow meter The top of the ball is the read mark for the scale Notice on handling see the Instructions for Use for the flow meter and for the gas sampling pump 4 5 Circuit breaker...

Страница 6: ...E depending on the chemical resistance to the target gas When using other hose materials or diameters a transition to 6 x 1 mm PTFE hose must be created Cut off hose squarely Assembly instructions for...

Страница 7: ...the flow meter 5 3 4 Wiring diagram The electrical connection of the installed intrinsically safe equipment to the and terminals is carried out in accordance with the following illustration and table...

Страница 8: ...or delivering sample gas have no mechanical parts subject to wear and are therefore maintenance free Gas transmitter Maintenance and servicing of the gas transmitter should be carried out according to...

Страница 9: ...on SE Ex PR DD Power supply 24 V 20 0 15 A 4 to 20 mA 0 mA Controller Unit max cable length 50 m 100 m 150 m core cross section 0 5 mm2 1 0 mm2 1 5 mm2 1 2 3 1 2 3 PEX 3000 all types PEX 3000 types XT...

Страница 10: ...tegory 1 classification must be cut out of the rating plate hanger at the location provided Once the equipment has been operated in accordance with this installation it may no longer be installed in m...

Страница 11: ...o 20 mA current source source operation Wiring diagram for operation as a 4 to 20 mA current sink sink operation 2123944_en eps RS 1 2 3 4 5 6 power supply red black brown white green yellow central d...

Страница 12: ...e base plate Additional equipment Gas sampling pump not for Ex areas PM21772 87 N87 TTE ISW KNF Gas sampling pump for Ex areas PM21773 87 N87 TTE Ex ISW KNF Protective housing 500 x 500 x 300 mm plast...

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ...o KGaA Revalstra e 1 23560 L beck Germany Tel 49 451 882 0 Fax 49 451 882 20 80 www draeger com 90 23 944 GA 4675 790 de Dr ger Safety AG Co KGaA Edition 02 September 2013 Edition 01 October 2006 Subj...

Отзывы: