Preparing Operation
24
Подготовка к эксплуатации
Switch off Bodyguard:
●
Simultaneously press the right and
left hand button until a single sharp
audible "Bleep" sounds.
●
Release buttons.
— For 3 seconds Bodyguard shows the
battery status.
— Bodyguard switches off.
If a fault is detected during the high-
pressure leak test:
— The X icon appears on the display.
— Alarm bleeps four times.
WARNING
The X icon indicates an error during
the high-pressure leak test.
Do not use the PSS BG 4 if a fault is
detected! Repeat the high-pressure
leak test or either return the device to
Dräger or have it repaired by duly quali-
fied personnel.
Failure to follow this warning could
lead to death or serious injury.
1
282
1
50
7
.eps
bar
4x Bleep
Выключите Bodyguard:
●
Одновременно нажмите и
удерживайте правую и левую
кнопки, пока прибор не подаст
однократный резкий звуковой
сигнал.
●
Отпустите кнопки.
–
В течение 3-х секунд Bodyguard
показывает состояние батареи.
–
Bodyguard выключается.
Если при проверке утечки из
высоконапорного шланга
обнаружена неисправность:
–
На дисплей выводится значок X.
–
Подается 4-кратный сигнал
тревоги.
ОСТОРОЖНО
Значок X указывает на
неисправность во время проверки
утечек из высоконапорных линий.
PSS BG 4 не должен использоваться,
если обнаружена неисправность!
Повторите проверку утечек из
высоконапорных линий, или
возвратите устройство Dr
ä
ger, или
отремонтируйте с привлечением
квалифицированного персонала.
Игнорирование данного
предупреждения может привести к
гибели или серьезной травме.
Содержание PSS BG 4
Страница 79: ...79 Order List Спецификация заказа ...