Technical Data
9023744 - 3rd edition - October 2005
Sensing Heads SE Ex
Dimensions
— Transmitter Ex / Ex R, page 28
— Sensing Head SE Ex, page 29
Sensing head SE Ex PR M
Part number
68 09 758
Operational parameters
Constant current, sensor current:
270 mA
Voltage at test points
891 mV
Device description acc. to Directive 94/9/EC
Dräger Safety, D-23560 Lübeck, Germany
Type SE Ex PR M ET
II 2G EEx de IIC T4/T5/T6
DMT 97 ATEX E 006X
C
0158
, year of manufacturing by serial number
1)
1)
The year of manufacturing is coded by the third capital letter of the serial number on the type plate:
S = 2002, T = 2003, U = 2004, W = 2005, X = 2006, Y = 2007, Z = 2008, A = 2009, B = 2010, C = 2011, etc.
Example:
Serial number: ARSH-0054, the 3rd capital letter is S, so the year of manufacturing is 2002.
Sensing head SE Ex LC M
Part number
68 10 486
Operational parameters
Constant current, sensor current:
276 mA
Voltage at test points
911 mV
Device description acc. to Directive 94/9/EC
Dräger Safety, D-23560 Lübeck, Germany
Type SE Ex LC M
II 2G EEx de IIC T4/T5/T6
DMT 97 ATEX E 006X
C
0158
, year of manufacturing by serial number
1)
Содержание Polytron Ex
Страница 29: ...9023744 3rd edition October 2005 Page 29 of 40 Technical Data Sensing Head SE Ex 45 mm 68 mm 03923744_1 eps...
Страница 33: ...9023744 3rd edition October 2005 Page 33 of 40 EC Type Examination Certi cate BVS 03 ATEX E 160 X...
Страница 34: ...Page 34 of 40 9023744 3rd edition October 2005...
Страница 35: ...9023744 3rd edition October 2005 Page 35 of 40 EC Type Examination Certi cate BVS 03 ATEX E 160 X...
Страница 36: ...Declaration of Conformity Page 36 of 40 9023744 3rd edition October 2005 Declaration of Conformity...