9023744 - 3rd edition - October 2005
Page 17 of 40
Start-Up
Sensitivity Adjustment
Using commercially available test gas:
●
Depending on the sensing head used supply the recommended calibration gas
concentration (s. table below) at a flow rate of approx. 0.5 L/min via the calibration
adapter.
Recommended concentrations:
— The calibration gas must be a mixture of the gas component to be monitored in
air. Mixtures with nitrogen are not suitable!
Once measured value display has stabilized (after max. 3 minutes):
1
Adjust sensitivity on potentiometer of the transmitter Polytron Ex R such that dis-
play indicates the calibration gas concentration.
When using the sensing head SE Ex LC M:
— The gas concentration is displayed without the decimal point, so the true concen-
tration is a tenth of the reading in % LEL.
— For calibration with solvent vapours, use can be made of the calibration chamber
(see Order List, page 31) in which a specified amount of solvent is evaporated, so
as to obtain, for example, 50 % LEL.
Adjustment is carried out as for calibration gas.
— The use of a calibration chamber requires appropriate training and knowledge on
the part of the operating personnel. Pay attention to usage instructions provided
with the calibration chamber!
If it is no longer possible to adjust sensitivity due to inadequate sensor sensitivity
(measured value to low),
or
if the measured value display does not stabilize after 3 minutes, the Ex-sensor must
be replaced (refer to page 22).
Following Completion of Calibration:
1
Set sliding switch to position »0« = normal.
2
Use special key to close flap in front of adjusters.
Sensing head
Full scale value
Calibration gas concentration
SE Ex PR M
100 % LEL
10 to 50 % LEL
SE Ex LC M
10 % LEL
3 to 7 % LEL
02623
7
4
4_1_en.eps
Test gas
02323
7
4
4_1
.eps
1
02823
7
4
4_1
.eps
1
Содержание Polytron Ex
Страница 29: ...9023744 3rd edition October 2005 Page 29 of 40 Technical Data Sensing Head SE Ex 45 mm 68 mm 03923744_1 eps...
Страница 33: ...9023744 3rd edition October 2005 Page 33 of 40 EC Type Examination Certi cate BVS 03 ATEX E 160 X...
Страница 34: ...Page 34 of 40 9023744 3rd edition October 2005...
Страница 35: ...9023744 3rd edition October 2005 Page 35 of 40 EC Type Examination Certi cate BVS 03 ATEX E 160 X...
Страница 36: ...Declaration of Conformity Page 36 of 40 9023744 3rd edition October 2005 Declaration of Conformity...