background image

Alternative C (supply from mobile compressed air source):

3

Like alternative A

4/11

such as ageing. A and if the compressed air supply hose is not part 
of the mobile air source, connect it to the mobile air source

6

n/a

5

Like alternative A

7

n/a

*

activate mobile compressed air source

2

Like alternative A

1

Like alternative A

After use

Leave hazard area.

1

Remove full-face mask

1)

.

4

Disconnect compressed air supply hose:
Firmly press both coupling halves together and pull back outer sleeve 
at same time until coupling disengages. Fit caps.

3

Undo waist belt.

Take off apparatus and turn off compressed air supply.

Maintenance and care

See "Maintenance intervals".
Clean, disinfect and dry mask.
For breathing hose:

Clean: 

Must be cleaned after every use. Do not use solvents, such as acetone, 

alcohol, etc. Clean with lukewarm water containing the all-purpose detergent 
Sekusept Cleaner

2)

 and a cloth. Then allow to dry at room temperature.

Check correct functioning and absence of leaks

Assemble compressed air line breathing apparatus as described for 

"Use". Without 

mask

 and breathing hose.

Start up compressed air supply system and check operating pressure 
(required: 7 - 10 bar) adjust if necessary.

Brush the connections and screw connections with soapy water 
when at operating pressure. No bubbles should form. Tighten seals 
if necessary.

Function test: 
The excess valve is integrated in the breathing hose which connects 
the ABIL-R1/ABIL-R2 with the half or full face mask.
Close the control valve and seal the excess valve. A low volumetric 
air flow must be noticeable. 
Open the control valve completely. A high volumetric air flow must be 
noticeable.

Storage

All parts must be stored in a dry, cool and dust-free place where they cannot be 

deformed. Keep away from direct light and heat. 
Observe ISO 2230 and national regulations for the storage, maintenance and 
cleaning of rubber products.

Technical data

Troubleshooting

Maintenance intervals

1)

Note the associated instructions for use.

2)

Made by Messrs. Henkel Hygiene GmbH, D-40554 Düsseldorf, Germany.
Note the associated Instructions for Use

Compressed air hose

Max. length 3 m

Compressed air supply hose

Max. length 50 m,
antistatic, heat-resistant

Respiratory air

As per EN 12 021

Do not use oxygen or 
oxygen-enriched air.

Operating pressure

7 - 10 bar

Temperature in use

–10 °C to 60 °C, 
refer to "Use"

Volumetric air flow

Min.

300 litres per minute

Max.

1000 litres per minute

Fault

Cause Remedy

Unpleasant taste

Respiratory air does not 
conform to EN 12021

Check all filters and 
replace and smell  if 
necessary

No air

Cylinder valve closed

Open cylinder valve

Couplings not closed

Check couplings

Hose jammed

Check hoses

Air flow too low

Control valve turned 
down

Open control valve

Operating pressure too 
low

Set operating pressure

Hose too long

Check hose length

Filter contaminated

Replace filter

Air flow too high

Control valve open wide Turn control valve down
Operating pressure too 
high

Set operating pressure

Equipment 
item

Work required

Before each use

After each use

Half-yearly

Y

early

Every 6 years

Full-face mask

1)

 

and breathing 
hose

1)

Note the associated instructions for use.

Clean, disinfect, dry

X

Couplings

Use a test gauge to check the 
plug-in coupling for wear 
Check that the couplings are 
free-moving

X

X

Complete 
compressed air 
line breathing 
apparatus

Clean outside
Rinse inside with air 
Check correct functioning and 
absence of leaks

X

X

X

X

X

Compressed air 
cylinder

Charge
Check charging pressure
Expert testing

X

X

X

2)

2)

e.g. by Dräger Safety

Pressure 
reducer

Replace high-pressure 
gaskets 
General overhaul

X

2)

X

2)

Fine 
compressed 
air filter

Replace filter cartridge

X

3)

3)

Only if there is a smell of oil.

X

Содержание ABIL-R Series

Страница 1: ...Notice d utilisation 10 nl Gebruiksaanwijzing 13 es Instrucciones de uso 16 it Istruzioni per l uso 19 ptBR Instru es de servi o 22 da Brugsanvisning 25 no Bruksanvisning 28 sv Bruksanvisning 31 fi K...

Страница 2: ...2 Bitte aufklappen Please fold out D pliez s v p Openklappen a u b Abrir aqu Si prega di ribaltare Fold venligst ud Favor de abrir Brett opp V g ppna K nn sivua L tfen a n z...

Страница 3: ...Configuratiemogelijkheden Posibilidades de configuraci n Opzioni di configurazione Possibilidades de configura o Konfigurationsmuligheder Konfigurasjonsmuligheter Konfigurationsm jligheter Konfiguroin...

Страница 4: ...wie ABIL R 1 jedoch mit zus tzlichem Ausgang f r den Anschluss eines Arbeitsger tes z B Farbspritz Pistole Dieser Ausgang darf nicht benutzt werden f r den Anschluss eines zweiten Lungenautomaten ode...

Страница 5: ...ohne Verformung trocken k hl und staubfrei lagern Vor direkter Licht und W rmeeinstrahlung sch tzen ISO 2230 und nationale Richtlinien f r Lagerung Wartung und Reinigung von Gummierzeugnissen beachten...

Страница 6: ...BIL R 1 AL 01 265 ABIL R 2 AL 01 266 F r die Versorgung aus ortsfestem Atemluftnetz Ringleitung Anschluss Set 3 4 AL 01 233 Filterstation AF 1400 SR 05 104 Druckluft Feinfilter R 27 944 Druckluft Fein...

Страница 7: ...itional port for connecting equipment e g paint spray gun This port must not be used to connect a second demand valve or to connect the Y piece R 27 945 The manifold can be worn on either the right or...

Страница 8: ...ed Keep away from direct light and heat Observe ISO 2230 and national regulations for the storage maintenance and cleaning of rubber products Technical data Troubleshooting Maintenance intervals 1 Not...

Страница 9: ...01 265 ABIL R 2 AL 01 266 For supply from a stationary breathing air network loop Connection set 3 4 AL 01 233 Filter station AF 1400 SR 05 104 Fine compressed air filter R 27 944 Fine compressed air...

Страница 10: ...peut pas tre ferm e compl tement ABIL R 2 idem ABIL R 1 mais avec une sortie suppl mentaire pour le raccordement d un outil p ex pistolet air comprim Cette sortie ne doit pas tre utilis e pour le rac...

Страница 11: ...t propre Garder l abri du soleil et des rayons thermiques Respecter la norme ISO 2230 et les directives nationales pour le stockage la maintenance et le nettoyage de produits en caoutchouc Caract rist...

Страница 12: ...l alimentation partir d un r seau d air comprim stationnaire r seau en boucle Kit de raccords 3 4 AL01233 Station de filtrage AF 1400 SR 05 104 Filtre fin pour air comprim R 27 944 Cartouche du filtre...

Страница 13: ...er met aanvullende uitgang voor het aansluiten van gereedschap bijv een verfspuit Deze uitgang mag niet worden gebruikt voor het aansluiten van een ademautomaat of voor het aansluiten van het Y stuk R...

Страница 14: ...n zonder vervorming droog koel en stofvrij opslaan ISO 2230 en nationale richtlijnen voor opslag onderhoud en reiniging van rubberproducten in acht nemen Technische gegevens Hulp bij pech Intervallen...

Страница 15: ...IL R 1 AL 01 265 ABIL R 2 AL 01 266 Voor de voeding uit een stationair ademhalingsluchtnet ringleiding Aansluitset 3 4 AL01233 Filterstation AF 1400 SR 05 104 Perslucht microfilter R 27 944 Perslucht...

Страница 16: ...v lvula reguladora integrada la cantidad de aire puede adaptarse al esfuerzo La v lvula reguladora no sirve como v lvula de cierre no se puede cerrar por completo ABIL R 2 como ABIL R 1 pero con sali...

Страница 17: ...m scara facial completa Cerrar la v lvula reguladora y bloquear la v lvula de exceso Se tiene que percibir un flujo volum trico de aire reducido Abrir la v lvula reguladora completamente Se tiene que...

Страница 18: ...esde una red fija de aire de respiraci n conducto circular Juego de conexi n 3 4 AL01233 Estaci n de filtrado AF 1400 SR 05 104 Filtro fino para aire comprimido R 27 944 Cartucho para filtro fino para...

Страница 19: ...aria pu essere adattata al carico tramite una valvola di regolazione integrata La valvola di regolazione non serve come valvola d intercettazione essa non pu essere chiusa completamente ABIL R 2 Come...

Страница 20: ...o facciale Chiudere la valvola regolatrice e assicurare la tenuta della valvola di supero Si dovrebbe avvertire una minore portata in volume dell aria Aprire completamente la valvola regolatrice Si do...

Страница 21: ...2 AL 01 266 Per l alimentazione da una rete fissa locale di aria respirata tubazione ad anello Set di collegamento 3 4 AL01233 Stazione filtrante AF 1400 SR 05 104 Filtro fine aria compressa R 27 944...

Страница 22: ...a v lvula de regula o integrada A v lvula de regula o n o serve como v lvula de bloqueio n o pode ser fechada completamente ABIL R 2 como o ABIL R 1 mas com sa da adicional para a conex o de um aparel...

Страница 23: ...excesso Tem de ser percet vel um ligeiro caudal de ar Abrir completamente a v lvula reguladora Tem de ser percet vel um grande caudal de ar Armazenagem Armazenar todas as pe as sem deforma o num s tio...

Страница 24: ...01 266 Para o abastecimento da rede fixa de ar respirat rio linha anular Conjunto de conex o 3 4 AL01233 Esta o de filtragem AF 1400 SR 05 104 Filtro fino de ar comprimido R 27 944 Cartucho do filtro...

Страница 25: ...a udgang til tilslutning af et arbejdsapparat fx spr jtepistol Denne udgang m ikke benyttes til tilslutning af en lungeautomat eller til tilslutning af Y stykket R 27 945 Fordeleren kan b res p s vel...

Страница 26: ...lys og varmep virkning F lg ISO 2230 og de nationale bestemmelser for opbevaring vedligeholdelse og reng ring af gummiprodukter Tekniske data Afhj lpning af fejl Vedligeholdelsesintervaller 1 Tilh re...

Страница 27: ...teenhed ABIL R 1 AL 01 265 ABIL R 2 AL 01 266 For tilf rsel fra station rt system for ind ndingsluft ringledning Tilslutningss t 3 4 AL01233 Filterstation AF 1400 SR 05 104 Trykluftfinfilter R 27 944...

Страница 28: ...stra uttak for tilkopling av et arbeidsapparat f eks malingsspr ytepistol Dette uttaket m ikke benyttes for tilkopling av en doseringsventil eller for tilkopling av Y stykket R 27 945 Fordeleren kan h...

Страница 29: ...st vfritt Beskytt dem mot direkte lys og varmestr ling F lg ISO 2230 og nasjonale retningslinjer for lagring vedlikehold og rengj ring av gummiprodukter Tekniske data Probleml sning Vedlikeholdsinterv...

Страница 30: ...et ABIL R 1 AL 01 265 ABIL R 2 AL 01 266 For tilf rsel fra stasjon rt puste luftnett ringledning Koblingssett 3 4 AL01233 Filterstasjon AF 1400 SR 05 104 Trykkluft mikrofilter R 27 944 trykkluft mikro...

Страница 31: ...f rgspruta Denna utg ng f r inte anv ndas f r anslutning av en andningsventil eller f r anslutning av Y stycket R 27 945 F rdelaren kan b ras s v l till v nster som h ger p midjan Vrid clipset vid byt...

Страница 32: ...direkt ljus och v rmebestr lning F lj ISO 2230 och nationella riktlinjer f r f rvaring underh ll och reng ring av gummiprodukter Tekniska data Hj lp vid funktionsst rning Underh llsintervaller 1 F lj...

Страница 33: ...1 AL 01 265 ABIL R 2 AL 01 266 F r f rs rjning fr n station rt andningsluftn t ringledning Anslutningsset 3 4 AL 01 233 Filterstation AF 1400 SR 05 104 Tryckluftsfinfilter R 27 944 Tryckluftsfinfilte...

Страница 34: ...ei saa k ytt toisen paineilmahengityslaitteen liitt miseksi tai Y kappaleen R 27 945 liitt miseksi Jako osaa voidaan kantaa vy t r ll joko oikealla tai vasemmalla puolella Vaihdettaessa k nn liitin K...

Страница 35: ...aikassa Suojaa suoralta valolta ja l mm lt Noudata standardin SFS ISO 2230 sis lt mi kumituotteiden s ilytyst huoltoa ja puhdistusta koskevia ohjeita Tekniset tiedot Vianm ritys Huoltov lit 1 Noudata...

Страница 36: ...1 265 ABIL R 1 AL 01 266 Sy tt n kiinte st hengitysilmaverkosta rengasjohto Liit nt setti 3 4 AL01233 Suodatinasema AF 1400 SR 05 104 Paineilman hienosuodatin R 27 944 Paineilman hienosuodattimen pano...

Страница 37: ...ihaz n rn boya tabancas ba lanmas i in ek bir k a sahiptir Bu ikinci k asla ikinci bir akci er otomat n n ba lanmas i in veya R 27 945 Y par as n n ba lanmas i in kullan lmamal d r Da t c belin sa nda...

Страница 38: ...serin ve tozsuz bir ortamda muhafaza ediniz Do rudan etki eden s cakl ktan ve g n ndan koruyunuz ISO 2230 u ve plastik r nlerin depolamas na bak m na ve temizlenmesine y nelik ulusal y netmelikleri d...

Страница 39: ...66 Bulunulana mekana sabit ba l solunum havas ebekesinden besleme kapal devre hat Ba lant seti 3 4 AL 01 233 Filtre istasyonu AF 1400 SR 05 104 Bas n l hava hassas ince filtresi R 27 944 Bas n l hava...

Страница 40: ...y AG Co KGaA ABIL R 2 ABIL R 4 ABIL R EN 14594 2005 F ABIL R 1 2 3 5 6 11 Dr ger 3 4 5 6 11 EN 12 021 A 4 5 6 7 10 B 4 5 8 9 C Airpack Quad Pack 4 5 11 ABIL R 1 50 m 2 ABIL R 2 ABIL R 1 R 27 945 A 3 4...

Страница 41: ...A 6 5 A 7 2 A 1 A 1 1 4 3 Sekusept Cleaner2 7 10 bar ABIL R1 ABIL R2 ISO 2230 1 2 Ecolab D 40589 D sseldorf 3 m 50 m EN 12 021 7 10 bar 10 C 60 C 300 1 000 EN 12 021 6 1 1 X X X X X X X X X X X2 2 Dr...

Страница 42: ...56 310 X plore 6300 EPDM PMMA RA K bl R 55 800 X plore 6530 EPDM PC CR R 1525 R 54 910 ABIL R 1 AL 01 265 ABIL R 2 AL 01 266 3 4 AL01233 AF 1400 SR 05 104 R 27 944 CH 106 R 27 945 5 m AL 01 260 10 m...

Страница 43: ......

Страница 44: ......

Страница 45: ......

Страница 46: ...6 Subject to alteration Dr ger Safety AG Co KGaA Revalstrasse 1 23560 Luebeck Tel 49 451 882 0 Fax 49 451 882 2080 www draeger com Notified body Involved in type approval and in quality control DEKRA...

Отзывы: