Chapter 5: Troubleshooting
Most problems are easy to fix. Consult the Troubleshooting Table below for common problems and their solutions. If you
continue to experience problems, contact us at www.DRpower.com or call toll-free 1-800-DR-OWNER (376-9637) for support.
Troubleshooting Table
S
YMPTOM
P
OSSIBLE
C
AUSE
;
C
ORRECTIVE
A
CTION
Engine fails to start
On/Off switch in OFF position; Move On/Off Switch to ON position.
Bag Top Cover not fully closed; Check that the bag is installed properly and not preventing
Bag top cover from closing and locking fully.
Fuel Tank empty; Fill Tank with clean, fresh fuel.
Spark Plug wire disconnected; Connect Wire to Spark Plug.
Faulty Spark Plug; Clean, adjust gap or replace the Spark Plug.
Loss of power, operation
erratic
Spark Plug Wire loose; Connect and tighten Spark Plug Wire.
Blocked fuel line or stale fuel; Clean fuel line; fill tank with clean, fresh gasoline.
Water or dirt in fuel system; Disconnect fuel line at carburetor to drain fuel tank.
Carburetor out of adjustment; contact us at www.DRpower.com or call 1-800-DR-OWNER
(376-9637) for assistance.
Dirty air cleaner; Clean or replace air filter.
Engine overheats
Carburetor not adjusted properly; contact us at www.DRpower.com or call 1-800-DR-OWNER
(376-9637) for assistance.
Engine Oil level low; Fill crankcase with proper Oil.
Internal Engine cooling fan not working properly due to debris buildup over Engine crank
cover; Clean debris away from Engine crank cover for improved air circulation.
Unit does not discharge into
bag
Discharge Hose clogged; Stop Engine immediately and disconnect spark plug wire. Clean
inside of blower housing. See “MAINTENANCE” sec
tion of this manual.
Foreign object lodged in Impeller; Stop Engine immediately and disconnect Spark Plug wire.
Remove lodged object.
Excessive vibration.
Loose parts or damaged Impeller assembly; Stop Engine immediately and disconnect Spark
Plug wire. Tighten all Bolts & Nuts. Make all necessary repairs. If vibration continues,
contact us at www.DRpower.com or call 1-800-DR-OWNER (376-9637) for assistance.
Chipper does not work
(XTSP Model)
Solid object jammed in unit; Check & remove any obstruction.
Broken or missing Chipper Knife; Replace Knife.
Poor chipping performance
(XTSP Model)
Dull Chipper Knife; Replace Knife.
Engine not reaching full RPM; contact us at www.DRpower.com or call 1-800-DR-OWNER
(376-9637) for assistance.
Excessively worn Engine shaft bearings; contact us at www.DRpower.com or call 1-800-DR-
OWNER (376-9637) for assistance.
Loose mounting Bolt on Impeller assembly; Tighten bolt.
Loss of vacuum
Vacuum Snout clogged; Remove & clean.
Collection Bag full; Empty full bag and replace the bag or remove the full bag and replace
with a new empty bag.
Discharge Hose clogged; Clean Hose.
Processing chamber clogged; Remove Vacuum Snout to clean chamber.
Engine not reaching full RPM; contact us at www.DRpower.com or call 1-800-DR-OWNER
(376-9637) for assistance.
Before performing any maintenance procedure or inspection, stop the Engine and wait five minutes to allow all parts to cool.
Disconnect the Spark Plug Wire, keeping it away from the Spark Plug.
Содержание PILOT XT
Страница 12: ...12 DR LEAF and LAWN VACUUM Figure 16 Figure 17 Figure 18 Bag Clamping Ring...
Страница 25: ...CONTACT US AT www DRpower com 25...
Страница 27: ...CONTACT US AT www DRpower com 27 Schematic Pro Handlebar and Bagger Assembly XT Model...
Страница 29: ...CONTACT US AT www DRpower com 29 Schematic Drive Assembly XT Model...
Страница 31: ...CONTACT US AT www DRpower com 31 Schematic Pro Handlebar and Bagger Assembly XTSP Model...
Страница 33: ...CONTACT US AT www DRpower com 33 Schematic Drive Assembly XTSP Model...
Страница 35: ...CONTACT US AT www DRpower com 35 Notes...